REGISTERED No. D. (D)-72
The Gazette of India
EXTRAORDINARY
PART II—Section 3—Sub-section (i)
PUBLISHED BY AUTHORITY
No. 66]
NEW DELHI, TUESDAY, FEBRUARY 24, 1981/PHALGUNA 5, 1902
Separate paging is given to this Part in order that it may be filed as a separate
compilation
1367 GI/80—1
(287)
288
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)l
289
290
THE GAZETTE OF INDIA: EXTRAORDINARY
[FAKT II—SEC. 3(i)l
291
292
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)j
2<-n
294
THE GAZETTE OF INDIA: EXTRAORDINARY
[PARt Jr—SFr. 3(07
295
1367 GI/80—2
296
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II- SEC. 3(i)]
297
298
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)]
299
300
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 30)|
301
302
THE GAZETTE OF INDIA: EXTRAORDINARY
[P.v.r II—SEC. 30)]
303
1367 GI/80-3
304
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)l
305
306
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)]
307
308
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)]
309
310
THE GAZETTE OF INDIA . EXTRAORDINARY
[PXRT II—SEC. 3(i)l
311
1367GT/80—4
312
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)l
313
314
THE GAZETTE OF INDIA: EXTRAORDINARY
[PARr II—SEC. 3(0]
MINISTRY OF INDUSTRY
(Department of Indiu*ial Development)
NOTIFICATION
Ntw Delhi, the 24th February, 1981
CS.R. 77(E)
Whereas a draft of the revised Gas Cylin-
ders Rules, was published as required by section 18 of the
Indian Explosives Act, 1884 (4 of 1884), at pages 1131 to
1138/12 of the Gazette of Indja, Extraordinary. Part n,
Section 3, Sub-section (i), dated the 1st September, 1979,
under the notification of the Government of India in the
Ministry of Industry (Department of Industrial Development)
No G.SR. 523 (E), dated the 1st September, 1979 inviting
objections and suggestions from all persons likely to be
affected thereby, before the expiry of a period of 45 days from
the date of publication of the said notification in the Official
Gazette;
And whereas the wild Gazette was made available to the
public on the 22nd September, 1979;
And whereas objections and suggestions received ftotu tbo
public on the said draft Rules have been considered by the
Central Government,
Now, therefore, in exercise of the powers conferred bv
sections 5 and 7 of the Indian
Explosives Act, 1884
(4 of 1884), the Central Government hereby makes the fol-
lowing rules, namely:—
GAS CYLINDERS RULES, 1981
CHAPTER I—PRELIMINARY
1 Short title and commencement—(1) These rules inay
be called the Gas Cylinders Rules, 1981
(2) They shall come into foice on the date of their publi
cation in the Official Gazette
2. Definitions—In these rules the context otheiwise re-
quire*,—
(i) "Act" means tho Indian Explosives Act, J884 (4 of
1884);
lu) "Chief Controller" mc<ms the Chief Controller of
Explosives, Government of India ;
(m) 'competent person" means a person recognise^ by
the Chief Controller to be a. competent persdrt, or
.i person who holds a certificate of competency foi
the job in rcspeu of which competency is required
from iin institution recognised b\ the Chief Con
trailer in this bebalf,
(iv) "compiessed giis" means any permanent gas, hquc
fiable gns or gas dissolved in liquid under pressmc
or gas mixture which in a dosed gas cylinder exci-
clses a pressure either exceeding 2 5 Kgf /Cin'abs
(15 Kit/Cm1
gnuge) at +15°C or a pressure ex-
ceeding 3 Kgf/Cm3 abs
(2 Kgf/CmJ faujjo) at
+ 50°C or both,
Explanation—Hydrogen floundo falls within ilic
scope of compressed fins although jts vapour pres-
sure at 50°C is 1 7 to 1 8 atmospheric gauge;
(v) 'Conservatoi" in i elation to a port includes anv
person acting under the authority of the officer or
body of persons appointed to be Conservator of
that port under Section 7 of the Indian Ports Act,
1908 (15 of 1908),
(\i) "Controller of Explosive:/' includes the Deputy Chief
Controllei of EiXplosn e<i. Deputy Controller of EJ.
plosncs and Assist int Controller of Explosives,
(vii) "critical temperature" means the temperature above
which gas cannot be liquefied by the application of
pressure alone;
(vin) "dissolved acetylene cylinder" means a cylinder hav-
ing a valve and with or without safety devices, con-
taining a porous mass, a solvent for the storaijc
of dissolved acetylene and at least sufficient acetylene
to iaturato the solvent at almosphenc pressure and
at a temperature of +15°C
Explanation—Acetone or any other solvent u»ed
shall not be capable of chemical reaction witb the
acetylonc gas or with the porous mass or with the
metal of the cylinder or valve;
(i\) "dissolved gas means a gas which under pressure )s
dissolved In a fluid solvent appropriate to the parti-
cular gas as for example, acetylene in acetone oi
ammonia in water,
(x) "district authority" means—
(a) a Commissioner of Police or Deputy Comniis'.trjritr
of Police in any town having a Commissioner of
Police; and
(b) m any other place, the District Magistute;
(\i) "District Magistrate" includes an Additional District
Magistrate, and m the States of Punjab and HaryanR
md in the Karaikal, Mahe and Yanam area* of the
Union territory of Pondicherry, also includes a
Sub-Divisional Magistrate,
(xii) 'filling pressure" means the maximum pci miasible
sauge pressure, converted to + 15°C, at which a gas
cylinder for permanent gas or gas dissolved jnder
pressure can bo filled ,
(xm) "filling ratio" means the ratio of the weight of a
liquefiable gas introduced m the cylinder to the
weight of the water the cylinders will hold at 15 "C;
(xiv) "flammable eas" means any gas which, if either a
mixture of 13 per cent or less (by volume) with air
forms ft flammable marine or the flammability range
with air is greater than 12 per cent regardless of
the lower limit and these hmits shall be determined
at atmospheric temperature and pressure
Explanation —"Plamnnbibty range" means the
diflerence bitueen tht.' nmuuuun mil in ixioiujii ]KI
coniagM bj volume of the gas in mixture uuli JH
th.it luiins ,i flammable mixture,
(xv) "Form" means a Form set forth in Schedule V;
315
(xvij "Gas Cylinder" or "cylinder" means any closed metal
container intended for the storage and transport of
compressed gas, designed not to be fitted to a special
transport or under-carriage, and having a volume
exceeding 500 ml. but not exceeding 1000 litres;
(wiij "high pressure liqueflable gas" means a liquefiable gas
having a critical temperature between —1O°C and
+ 70"C.
Uviii) "hydrostatic stretch test" means subjecting the cylin-
der to a hydrostatic pressure equal to the test pres-
sure of lhe cylinder and recording the permanent
stretch undergone by the cylinder;
Cxix) "hydrostatic test" mean* the test to which a cylinder
is subjected to a hydrostatic, pressure equal to the
test pressure of the cylinder;
(ja) "irnpoit" means bringing into India by kind, »ca or
nir;
(xxij "inspecting authority" means a person having quali-
fications and wide experience in the field of design,
manufacture and testing of gas cylinders and recog-
nised by the Chief Controller as authority for ins-
pection and certification of gas cylinders;
(xxii) "installation" means any premises wherein any place
has been specially prepared for the manufacture
(filling) oi storage of compressed gas in cylinder;
(x\iii) "liquefiable gas'' means a gas that may be liquefied
by pressure at —10*C but will be completely vapo-
rised when in equilibrium with normal atmospheric
pressure (760 mm, hg.) at 30 "C ;
(xxiv) "low pressure liquefiable gas" means a liquefiable gas
having critical temperature higher than +70°C;
Uxv) "rnanufactuic of gas" means filling of a cylinder with
any compicssed Bas and also includes transfer oE
compressed gas from one cylinder to any other cy-
linder ;
(xxvi) "permauent gas" means a gas whose critical tempera-
ture is below —10°C that is to say a gas which
cannot be liquefied under any pressure at a tempera-
ture above —10" C;
(xxvii) "Schedule" means the Schedule annexed to these
j ules ;
(xxviii) "laie weight" in relation to,
(1) acetylene cylinder means the weight of the cylinder
together with any fittings, permanently attached
and includes the weight of valve any safely de-
vice, porous mass, requisite quantity of solvent for
dissolving acetylene, and the weight of. acetylene
gas saturating the solvent at atmospheric pressure
and temperature of 15°C.
(2) liquefiable gas cylinder means the weight of the
cylinder together with any fittings permanently
attached thereto and includes the weight of valve.
(3) permanent gas cylinder means the weight of the
cylinder together with any fittings permanently
attached thereto.
(JLMX) "test pressure" means the internal pressure required
for the hydrostatic test or hydrostatic stretch test
of the cylinder, as follows :—
(1) For permanent and high pressure liquefiable gases.
It should be calculated from the following;
200, t. Re
P n - — _
_ _ _ _
1.25 (Do-t)
where
Ph - lest pleasure in h'sf/Cm1.
Do = Outside diameter of the cyliudei in mm.
t = Minimum calculated wall thickness of the cylin-
der shell in mm.
Re =• Minimum specified yield strength of the mate-
rial of cylinder in Kgf/mma. It 13 limited 10 75
per cent of the minimum value of tensile strength
in the case of normalised cylinder and 85 per
cent of the minimum value of the tensile strength
for quenched and tempered cylinder, provided
that the value of lest pressure shall not exceed
80 per cent of iHe yield strength,
(2) 1-or low pressure liquefiable gas—One and u half
times the saturated vapour pressure of the gas at
65'C or as specified in Is : 8867, whichever is
higher.
(\xz) "Iranspoit" means the moving of a cylinder HlJcd
with any compressed gas fiorn one place to an-
other ;
(jotxi) '"water capacity" means the volume of water in litres,
a cylinder will hold at 15°C;
(xxxii) "working pressure for low pressure liquefiable gas"
means the saturated vapour pressure at 65 °C;
Explanation.—For the values of saturated vapour
pressure of different gases see IS : 3710;
(\x\iiij "woiking pressure for permanent gas" means the in-
ternal pressure of the gas in lhe cylinder at a ivm-
peiufurc of 15°C;
(xvxi\) "yield strength" means the sliess corresponding to a
pcimanent stiain of 0.2 per cent of the original gauge
length in a tensile test. For practical purposes it
may be taken as a stress at which elongation first
occurs in the test piece without tho incrca«o of load
in a tensile test.
CHAPTER II
GENERAL PROVISIONS
3. Filling, pussession, import and transport of cylinders,—
(1) No person shall 1111 any cylinder with any compressed ga»
or import, possess or transport any cylinder so filled or in-
tended to be filled wilh such gas unless :—
(a) such cylinder and its valve have been constructed to
a type and standard specified in Schedule I as
amended from time to time by an order issued by
the Chief Controller;
(b) the test and inspection certificates issued by the Ins-
pecting authority in respect of cylinder and its valve
are made available to the Chief Controller and prior
approval of the said authority is obtained.
(2j The test and inspection eeitiflcates required to be obtain-
ed from the inspecting authority in respect of cylinder* and
valves inspected and certified by it in accordance with the
approved design and specification or code shall give the in-
formation included in Schedule II.
(3) Any person desiring to fabricate cylinders, valves and
other filtinffs shall submit to the Chief Controller tho paai-
culars set forth in Schedule III.
(4) Notwithstanding anything contained in sub-rule (1),
cylinders of specifications not conforming to the specifications
specified in Schedule I and imported into India for filling and
shipment to the country of origin or supply to a foreign
going vessel touching Indian port, could be filled with such
gag, provided
(a) the cylinder has passed the hydraulic test or hydro-
static stretch test, as the case may be, within the
period specified in these rules and the pressujo ap-
plied during the test shall bo the test pressure mnrk-
ed on the cylinder,
(b) lhe i.yliikW is 1101 Illicit \vilh--
ti) any liquciiulile gu-, in excess of the filling ratto
specified in IS : 3710;
316
THE GAZETTE OF INDIA; EXTRAORDINARY
[PART II—SEC. 3(01
(ii) any permanent gas at a pressure in excess of the
pressure for which the cylinder is designed.
(c) a separate record of the cylinder tested and filled is
maintained at the filling station;
(d) the filled cylinders are removed from the filling sta-
tion and shipped off as cxpeditiously as possible.
4. Valve*.—(1) Valves fitted to gas cylinders shall comply in
all respects with the following specifications namely:—
(a) in respect of Industrial gas cylinders, IS : 3224;
(b) in Tespcct of Medical gas cylinders, IS : 3745;
(c) in respect of cylinders used with breathing apparatus,
IS : 7302 as amended fiom time to time;
(d) in respect of cylinders used for filling liquefied potio-
lcum gas, IS : 8776 for cylinders of water capacity
not exceeding 5 litres and, IS : 8737 for cyhndeis
of water capacity exceeding 5 litres :
Provided that the Chief Controller may, if he is of opinion
that it is necessary so to do in the public interest, permit the
use of valves not conforming to any of the specifications.
(2) Valves fitted to Carbon dio.\idc cylinders shall be pro-
vided in the body with a safety release consisting of softened
copper disc so arranged as to bur>t nt a pressure between 200
and 220 Kg/CraB.
(3) Valves for cylinders containing flammable gases not
listed in IS : 3224 shall have outlets provided with, left handed
screw threads for the pipes or other connections,
(4) All other valves shall have outlets with right handed
screw threads.
(5) The valves shall be attached to the cylinder neck by
screwing and not by making any permanent attachment or
inserting adapter in between.
(fi) The design of spindle operated vahes shall be such that
when fitted to the cylinders it shall not be possible to with-
draw the spindle under normal operating conditions
5. Safety Relief Devices.—<1) Cylinders manufactured in
India, If fitted with safety relief devices in their bodies, shall
have such safety devices manufactured and maintained in ac-
cordance with IS : 5903.
(2) Cylinders containing obnoxious or poisonous gaici
shall not be provided with any safety device,
Explanation.—For the purpose of this suhwule, "obnoxlou»
or poisonous gases" include Carbon monoxide, Hydro-Cyanic
Acid, Hydrogen Chloride, Hydrogen Bromide, Hydrogen Fluo-
ride, Sulphur Dioxide, Chlorine, Methyl Bromide, Nitrogen
tetroxide, Nitrosyl Chloride, Town gas, Hydrogen Sulphide,
Carbonyl Chloride (Phosgene), Cynogen, Cynogen Chloride,
Fluorino and Carbon Oxychloridc,
(3) Cylinders manufactured in foreign countries, approved
for use in this countiy, if fitted with safety relief devices shall
have these devices fully maintained in accordance with the
requirements of the specifications to which they were origi-
nally made.
6. Marking on Cylinders.—(1) Markings generally:
(a) Every gas cylinder shall be clearly and permanently
marked in accordance with the following conditions
by stamping, engraving or similar processes :
(i) on the shoulder of the cylinder which shall be in-
lorced by forging or other means, or
(if) on such a part which is inseparably bound with
the cylinder and which is not or only negligibly
effected by the stresses due to the gas pressure
within it,
(b) The name plate shall not be affixed to the cylinder
by soldering if there is a risk of corrosion or em-
brittlement.
Ic) In ciiiijuiii-tiiiii \nth ill/1 original marking, space shrill
be provided fui .stumping the test dale obtained at
the periodic inspection.
(d) Markings shall be so carried out and the letter* and
numerals used shall be of such shape and size that
the marking is clear and easily readable and does
not give place for misreading.
(2) Marking on permanent and liqueiiablc gas cylinders :
(a) Every cylinder shall be marked with the following
markings, namely:—
(i) manufacturei's, ownei's and
inspectors marking
and rotation number; (these markings shall be
registered with the Chief Controller);
(ii) specification to which the cylinder has been made;
(iiij a symbol to indicate the nature of heat treatment
(such as normalising, quenching or tempering given
to the cylinder during manufacture of after re-
pairs ;
(iv) the date of the last hydrostatic test or hydrostatic
stretch test, as the case may be, with the code
mark of recognised testing station where the test
was carried out. The code mark shall be registered
wiih the Chief Controller. In the case of liquefied
petroleum gas cylinders, the quarter and the year
of test shall be given as an additional marking
in a neck ring or on a shoulder plate;
(v) wot king pressure and test pressure;
(vi) tare weight;
Explanation.—In the case of liquefiable gas
cylinders, tare weight shall include tic weight of
valve fitted to the cylinder. The weight of the valve
shall be indicated separately.
(vii) water capacity.
(b) All the markings, except the manufacturer's maik-
ings, which may be on the base, shall be stamped
on the neck end of the cylinder,
7. Markings on valve.—Valves fitted to the cylinder shall
be clearly and durably marked in accordance with the follow-
ing provisions by stamping, engraving or similar processes:
(i) the specification of the valves;
(ii) year and quarter of manufacture;
(iii) manufactmcr's symbol;
(iv) working pressure;
(v) (he name or chemical symbol of the gas for which
the valve is to be used;
(vi) the type of screw threads on the outlet, namely left
handed (L.H.) or right handed (R.H.);
(vii) Inspector's stamp;
(viii) where dip tubes are provided, special indications (hall
be given by a clear nnd durable marking on the
valve or on a badge fixed between the valve and
the cylinder. The total length in mm. of the tube
shall also be indicated.
8. Identification colours.—(1) Every perion filling "any cylin-
der with any compressed gas shall, before it is stored or des-
patched, sec that the cylinder i^ painted with the appropriate
identification colours specified in IS : 4379 for industrial
cylinders and IS : 3933 for medical cylinders,
(2) Cylinders used for new gases and gas mixtures for
which identification colours are not provided in sub-rule (1)
shall be painted with the colours Indicated in the following
table, namely:—
Name of the gas con-
tained in the cylinder
1
Nnn-fUmmable and
nontoxic.
Colour
<
of the
cylinder
shell
White
Colour of band at neck
end of cylinder
3
317
1
2
1
Noi^ftommable but
White
Yellow (IS Standard Colour
toxic
No. 356).
Flammable but non-
White
Red (IS Standard
Colour
toxic other than
No. 537)
the LPG
Flammable and toxic White
Red and Yellow (IS stan-
dard colour Nos. 537 and
356).
Explanation.-—Cylinders intended for gas mixtures can be
maiked with the words "Gas Mixture" or "Mixed Gas". In
addition, the cylinders shall be marked with the names
(symbols if necessary) of the components of the mixture by
stumping, if the cylinders are intended for the permanent use
of the particular gas mixture, or by painting, if the cylinders
ure intended for the casual use of the particular gas mixture.
(3) No person shall in any way interfere with or change
the colour painted on a gas cylinder:
Provided that nothing in this sub-rule shall be deemed to
prohibit the re-painting of a cylinder with the identification
colour painted on it when it is required for the maintenance
of the cylinder or when a cylinder is converted from one gas
service to another gas service in accordance with these rules.
9. Labelling of cylinders.—(1) Every cylinder shall be
labelled with the name of the gas and the name and address
of the person by whom the cylinder was filled with gas.
(2) A warning in the following terms shall be attached to
every cylinder containing pcrmtnent or liqueflablo gas, name-
ly:—
"WARNINC-
Gaa Cylinders Rotes 19ftl
(i) Do not change the colour of this cylinder.
(ii) This cylinder should not be filled with any gas other
than the one it now contains.
(iii) No flammable material should be stored in the imme-
diate vicinity of this cylinder or in the same room
in which it is kept.
(iv) No oil or similar lubricant should be used on the
valves or other fittings of this cylinder,
(v) Please look for the next date of test, which is marked
on a metal ring inserted between the valve and the
neck of the cylinder, and if this date is over, do not
accept the cylinder,
10. Restriction on delivery or despatch of cylinders —(1) No
person shall deliver or despatch any cylinder filled with, any
compressed gas to any other person in India who is not
the holder of a licence to possess such compressed gas cylin-
ders or his authorised agent unless he is exempted under these
rule, to possess such compressed gas cylinders without a
licence,
(2) The pas cylinders delivered or despatched by a person
under sub-rule (!) shall be of the type for which he is licensed
and sha 1 not exceed the quantity which the person to whom
in 'S
1
°
r
d e s p a t c h c d
is authorised to possess under
(3) Nothing in sub-rules (1) and (2) shall apply to the deli-
very or despatch of gas cylinders to the Defence forces of
the Union, port authorities or Railway administration.
11 Repairing of seamless gas cylinders during use,—No ner
son shall repair or cause to repair any leakage in the body
of a seamless gas cylinder,
y
Jh/ss susttssn S ^ U K T £
<2) In ths fir* of r\!ind':r* listing Wrldtd/braied seam, tf
r-iirinj; of inmoi- d^tr'-r., such ,r, pniail v>cld tracks Pin holes,
blow holes, uudeiciUs in welding, leaks at the weld (shown
in periodical hydiostatic test) may be allowed provided—
(i) the defects huve been removed by grinding, chipping,
gouging or other approved methods;
(ii) the repairing is carried out by a certified welder at
the premises of a manufacturer of cylinders recog-
nised by the Chief Controller under the supervision
of a competent person b y -
la) welding if the original seams were welded;
(b) brazing, if the original seams were brazed;
(iii) the cylinder is properly heat-treated after the repairs;
(iv) ttis welded or brazed seams of the cylinder are radio-
graphed if the cylinder was originally required to
be radiographed after its manufacture;
(v) -after repairs and heat-treatment, the cylinder is iub-
jected to the same pneumatic and hydrostatic test or
hydrostatic stretch test as was done at the time of
manufacture,
(3) Welded or brazed cylinder, before repairing, shall be
thoroughly cleaned nnd gas-freed or otherwise prepared foi
safely carrying out hot work and certified in writing, by a
competent person, to have been so prepared. The certificate
shall be preserved for a period of three months and produced
to the Chief Controller on demand,
(4) No person shall refill any cylinder which has been
repaired under sub-rule (2) with any gas unless a full report
on the repairs and test carribd out on the cylinder, accom-
panied by the repairer's certificate of testing are furnished
to the Chief Controller and his permission is obtained for
its refilling.
(5) Notwithstanding anything contained in sub-rule (2), no
rcpaira shall be carried out to any dissolved acetylene gas
cylinder showing leaks in its weld seam,
13. Prohibition of employment of children and intoxicated
persons,—No child under the age of eighteen years and no
person who is in a stage of intoxication shall be employed in
loading or unloading or transport of any compressed ga»
cylinder or in any premises licensed under these rules,
14. Prohibition of smoking, fires, lights and dangerous subs-
tances.—<1) No person shall smoke and no fires, other than
blow pipp flames for repairs, or no articles or substances of
flammable nature or liable to spontaneous ignition or to cause
or communicate fire or explosion shall be allowed at any time
in proximity to a place where any cylinder for flammable
gases is being filled, stored or handled.
(2) No person in or near any place where cylinders con-
taining flammable gases are filled, stored or handled shall have
in his possession any matches, fuses or other appliances for
producing ignition or explosion,
15. General precautions.—(1) Cylinders together with their
valves and other fittings and the identification colours under
these rules shall always be maintained in good condition.
(2) No oil or similar lubricant shall be used on any valves
or other fittings of any cylinder.
(3) Save as provided in rules 12 and 41, no cylinder shall
be subjected to any heat treatment or exposed to n high
temperature or to the Sun or stored with any other flammable
or explosive material,
(4) Every cylinder containing compressed gas shall have
its valve securely closed so as to prevent leakage. Valves fitted
to the cylinders containing Liquefied Petroleum Gas and highly
toxic gases like Boron trifluoridc, Carbon monoxide, Flourine,
Hydrogen Chloride, Cynogcn Chloride, Chlorine trifluoride,
Hydrogen Cynide, Hydrogen Fluoride, Hydrogen Sulphide,
Methyl Bromide, Nitiogen tetroxide, Chlorine, Ammonia or
Sulphur Dioxide shall be provided with security nut on the
outlet to act as a secondaiy means of safeguard against leakage
of gas.
318
THE GAZETTE OF INDIA: EXTRAORDINARY
[P.�r II—SEC. 3(i)]
(5j If a leak in the \ahc cnnnet be rectified by tightening
1 J ) r
R
I
B
I
I
I
I
H
1 '
1
f
l r
t
h
r
t . r
1 " " " ' ' -
i
h
r
r
v
l
i
n
d
e
i
' • ' m i l
b
r
r
n
n
n
i
e
d
t
"
an open <p,ii-e wheie it is Icjst d.uiiirmii-i to life <nid propelly
and the filler shall be informed.
16. Special precaution's against accidents,—{1) No person
shall commit or attempt to commit any act which may tend to
cause a fire or explosion in or ubout any place where gas
under pressure in a cylinder is stored, handled or transported.
(2) Every person storing compressed gas cylinders and every
person in charge of or engaged in the storage handling and
transport of such gas cylindeis, shall at all times—
(a) comply with the provisions of these rules and the
conditions of any licence relating thereto ;
(b) observe all precautions for the prevention of accident
by fire or explosion ; and
(c) prevent any person from committing any act referred
to in sub-rule (1).
17. Competent person to be incharge of operations.—Kvery
person holding or acting under a licence granted under these
rules, shall, whenever cylinders are filled, loaded, unloaded,
examined or tested, depute a competent and experienced per-
son to be present and to conduct any of the said operations
in accordance with the provisions of these rules
18. Handling and use.—(1) Cylinders shall be adequately
supported during handling.
(2) Trolleys and cradles of adequate streneth '•hall, as fur
as possible, be used when moving the cylinder*.
(3) The cylinders shall be handled carefully nnd not be
allowed to fall upon one another or otherwise subjected to
any undue shock.
(4) Sliding, dropping or playing with cylinders is prohibited.
(5) Liquefied petroleum gas cylinders and cylinders con-
taining liquefiabie gases shall always be kept in an upright
position and shall be so placed that they cannot be knocked
o\er.
(6) Cylinders used in horizontal poeition shall be so secured
that they cannot roll.
(7) Open flames, lights, lighting of fires, welding and smok-
ing shall be. prohibited in close proximity to any cylinder
containing flammable {[ases except those whole in use for
welding, cutting or heating.
(8) Working places shall not be classified as storage places
for the purpose of licensing,
19. Restrictions on filling.—(1) Welded cylinders shall not
be used for filling any permanent or high pressure liquefiable
gas or highly toxic gases like Boron trichloride,
Carbonyl
Chloiidc (Phosgene), Chlorine trifluoride, Cynogen, Cynogen
Chloride, Hydrogen Cynide, Hydrogen Fluoride, Hydrogen
Sulphide,
(2) No cylinder which has once been used for storage and
transportation of coal gas shall be used for filling with any
other gas.
(3) No cylinder shall be filled with any jta« that is capable
of combining chertricnlly so as to endanger its serviceability.
20. Storage of cylinders.—(\) Cylinders shall be stored in
a cool, dry, well ventilated place under cover, away from
boilers, open flames, steam pipes or any potential sources of
heat and such place of storage shall be easily accessible,
(2) The storage room or shed shall be of fire resistant con-
struction.
(3) Thin wall cylinders such as liquefied petroleum gas
cylinders and dissolved gas cylinders shall not be stacked in
a horizontal position.
(4) Cylinders containing flammable gases and toxic gases
shall be kept separated from each other and from cylinders
containing other types of gases by an adequate distance or by
a suitable partition wall,
(5) Cylinders shall not be stored under conditions which
will cause them to corrode.
(fi) Cylinders -shall not be stored along with any comtmiri-
ble material,
(?) Empty cylinders shall be segregated frcm the filled one?
< < n < J
i
j
r
e
*
1
I
B
1
1
b
e
t
a
^
n
i
I
h
a
t
. i l l
t
h
e
v
a
h
r
p
a
r
c
l
i
f
t
h
l
l
y
' • b n t .fi-
ll,
tlcctncal installations.—In picmiseg for filling" and
storing flammable gases in cylinders all electric meters, dis-
tribution boards, switches, fuses, plugs and sockets, electric
fixed lamps, portable hand lamps and motors, shall be of
llame proof construction conforming to appropriate Indian
Standard Specifications or such other specifications as are
approved by the Chief Controller and shall be effectively
earth.
22. Puiity of gas.—(\) Compressed gases shall be free from
impurities which are likely to corrode the metal of the cylin-
der or form an explosive substance with it or cause the gaies
to decompose or explode,
(2) The gases shall be as dry as is possible and in nu
instance shall the aqueous phase separate when a liquefied
gas is cooled to O'C.
(3) Before filling any cylinder with gases like carbon mon-
oxide, coal gas, hydrogen or methane, the gas shall be tree
from hydrogen sulphide and oher sulphuious impurities a«
f.ir as practicable. The moisture shall be less than 0.02 g/m'
of gas at normal temperature and piessure.
23. Cylinder subjected to the action of fire,—(1) A cylinder
exposed to fire hhall not be used unless it has undergone
proper examination and hydraulic/hydrostatic stretch tesi.
If deleterious structural changes in the material duo to the
action of heat of the fire is apprehended to have taken place,
the cylinder shall havc to be subjected to proper heat treat-
ment, followed by hydrostatic test or hydrostatic stretch test,
;is the case may be, before the cylinder is taken into u«e,
(2) Dissolved acetylene cylinders which have been damaged
by fire shall be condemned ancj destroyed with due precautions
by an experienced and competent person.
24. Ownership of cylinder.—A cylinder filled with a com-
pressed gas shall not be transported unless it was charged by
or with the consent of the owner of the cylinder.
25. Rc-testing of cylinder,—A cylinder for which prescribed
periodical re-test has become due shall not be charged and
transported until such re-test has been properly made.
26. Owner's record.—The owner of a cylinder shall keep
for the life of each cylinder, a record containing the following
information regarding each cylinder, namely :—
(i) Cylinder manufacturer's name and the rotation -num-
ber;
(ii) The specification number to which the cylinder it
manufactured;
(iii) Date of original hydrostatic test/hydrostatic stretch
test;
(iv) Cylinder manufacturer's test and inspection certificates.
(V) Number and date of letter of approval granted by
the Chief Controller.
27. Conversion of cylinders.—Gas cylinders designed and
approved for filling with a particular gas shall not be used
for filling with any other gas unless specific approval Is obtain-
ed from the Chief Controller.
CHAPTER HI
Importation of Cylfankra
PART I—GENERAL
28. Licence for import of gas cylinders,—No person shall
import any cylinder filled or intended to be filled with any
compressed as except under and in accordance with the
conditions of a licence granted under these.
PART n
IMPORTATION BY SEA
29. Declaration by the Master of ship or ship's agent.—
(1) The master of every ship carrying cylinders filled with
compressed gas for importation into Tndia. or the agent for
such ship, shall give, the Conservator of the Port not less
than 48 hours' notice of its intended arrival at the port
319
(2) The master of cveiy ship carrying such cylinders shall
deliver to the pilot, hcfoie entenng any port, a written de-
claiation under his signature in Form A :
Provided that if the agent for such ship delivers to the
Oonscivator of the port a wiitten declaration referred to
in siib-iuie (1) undci his signature, no such declaration shall
be m;ide by the master of the ship.
(3) Fvery declaiation delivered to a pilot under sub-rule (2)
shall be made over by him without delay to the Couservator
of the Poit and all declarations received by the Conservator
of the Port shall be foi warded by him, with all convenient
despatch, to the Custom!, Collector of the Port.
30. Production of licence for imports—Evciy person desir-
ing to import cylinders filled with any compressed gas or in-
tended to be so filled shall produce personally or through
his agent, befote the Customs Collector bis licence for the
impOLt ot such g.is cylinders.
31. Permission of (he Customs Collectoi.—(J) No imported
cylinder shall be landed except with the permission of the
Customs Collector.
(2) If the Custom;, Collector is satisfied that the gas cylin-
deis can lawfully be imported, he shall permit it to be landed.
(3) Mothing in this rule shall affect the power of the Cus-
toms Collector to detain the gas cylinders under any other
law for the time being in force.
PART 111
Importation by Land
32, Importation bv Land—No gas cylinder filled with any
compressed gas, shall be imported by land save with the pre-
vious sanction in each case, of the Central Government and
under such conditions and restrictions as it may impose,
PART IV
Importation by ArV
33. Tmpoitation by Air.—No cylinder with any compressed
gas shall be imported by air save with the previous sanction
in each case of the Director General Civil Aviation.
CHAPTER IV
Transport of Cylinders
34. Transport of cylinders
by
vehicles—(1) Cylinders
filled with any compressed gag shall not be transported bv a
bicvele or any other two-wheeled
mechanically propelled
vehicle.
(2t Cvlinders shall be so transported as not to project
m the horizontal plane beyond the sides or ends of the
vehicle by which they are transported.
(3) There shall be DO sharp projections on the inside of
the vehicle.
(4) Cvlinders shall be adequatelv secured to prevent their
falling off the vehicle and being subjected to rough handling,
excessive shocks or local stresses.
(1) Cvlinders transported in vehicles shall be Mocked or
braced and be so secured to prevent movement, sti iking tacfj
other or falling down.
(6) Cylinders filled with any compressed ons shrill not be
transported alone with any other article of a highly flammable
or corrosive nature.
35. Restriction on
transport.—(1) Cylinders
containinR
flammable gases shall not be transported alonB with the
cylinders containing any other tvpe of compressed gas.
(2) Pviinders containing toxic or corrosive gas shall not
be transported along with food-stuffs.
36. T.oadine nnd unlondinc for transport —-(1) No lift-
Jnff mapnet shall be used in loading or unloading of cvlideii
filled wilb uny compressed gas.
(2) When anv such operation is carried on bv mea^ of a
crane or a fork-lift truck, a proper cradle with chains or
wire rop« slings shall be u«ed.
1367 GI/80—5
37. Protection of valves
during
transport.—(1) Every
cylinder containing compressed gas shall, when transported,
have it valve protected against damage in the manner pro-
vided in sub-rules (2) and (3) unless it is securely packed
in a box or crate,
(2) Where the design of the cylinder does not provide
for the valve lying wholly below the level of the body of
the cylinder, a stout metal cap, metal cover or a protective
metal ring or grill of a design approved by the Chief Cont-
roller shall be provided, the design being such that the
cap or cover or ring or grill is no where in close proximity
to any part of the valve or valve body.
(3) Wbire metal caps or metal covers are piovkled. to
protect valves fitted to cylinders other than those containing
highly toxic gases like Hydrogen Cyanide, Phosgene, Cyno-
gen, Cyanogen Chloride, it shall be provided with a vent
of such size so as to prevent any gas pressure inside the cap
or covers,
(4) Cylinders containing highly toxic gases like Hydro-
gen Cyanide, Phosgene, Cynogen, Cyanogen Chloride gases,
shall have their valves protected with gas-tight metal caps or
coven,
(5) Nothing in sub-rules (1), (21 and (3) shall apply to
cylinders containing oxyfien or nitrous
oxide
for
medical
purposes having water capacity not exceeding 5 litres,
38. L«aky cylinder*—(1) No person shall tender or trans-
poi t any lenky cylinder.
(21 Any cylinder containing a flammable or toxic gns,
which develops a leak during transport shall promptly be
removed to an isolated open place away from any source
of ignition and the person responilble for transportation
shall immediately contact thc filler or the consignor as the
case may be, for necessary advice.
CHAPTER V
Examination and testing of cylinders
39 Periodicity of examination and testing of cylinders.—-
(1) No person shall fill any cylinder with any compressed
gas unless the cylinder has been examined and subjected
to hydrostatic tost or hydrostatic stretch test, as the case
may be, and other tests set forth in this Chapter within such
period as is specified in thc Code issued by Indian Stan-
dards Institution or as approved in writing by the Chief
Controller.
(2) Any testing station desiring to obtain jeconnvtion for
periodical testing and examination of cylinders shall provide
the facilities set forth in Schedule IV.
40, Condition of
cylinders for
testing.—Cvlinders
for
testing shall be first emptied of their contents. The cylinder
contents shall be released in a safe manner keeping in mind
the dangers associated with the nature of thc pas in the
cylinder, Cvlinders which contain or mav bave been con-
taminated by, poisonous or obnoxious substances Miail be
emptied bv test stations properly equipped and sufficiently
experienced to handle the particular gas
i\
Ti=pection of cylinders before carrying out hydrostatic/
hydrostatic stretch test ,—-(11 Prior to carrying out hvdro-
'fntic/hvdrostntic stretch test, every cylinder shall be thorough-
Iv cleaned by steam cleaning or washing out with approved
solvents Where the interior of the cylinder is affected by rust
or other foieinn malter it shall be cleaned by one of thc
following methods namely :—
(n) Approved blasting, rotary wire brushing;
(b) Burn out treatment carried out in a furnace at a
temparature not exceeding 300*C for a period of
not exceeding one hour after which all free rusts
nnd anv other foreign matter shall be removed
bv 'team cleaning or washing with approved sol-
vwnti.
(2) The cylinders after cleaning ihall be visually exnmitted
externally and as far as practicable internnily for surface defect
In accordance with (he Code of Practice
issued
by the
Indian Standards Institution or any other Code approved in
writing by the Chief Controller.
320
THE GAZETTE OF INDIA: EXTRAORDINARY
[FART II—SEC. 3(i)]
42. Hydrostaticlbydroslatic stretch test.—(1)
For Cylin-
ders use for peioifincnt gnscs, high pirsswe liqnelifiblc (tasw
and all toxic and corrosive gases :—
(1) The cylinders shall bo subjected to hydrostatic stretch
test In accordance with IS:5844. The test pressure
applied to the cylinder shall be retained for a period
of not less than 30 seconds.
(ii) The permanent stretch suffered by the cylinder due
to application of test pressure shall not exceed the
following limits, namely :—
(a) In the case of cylinders 10% of the total stretch
below 20 litres water suffered
during
the
capacity for non-corro- test.
sive gases.
(b) In other cases.
10%
of
the
total
stretch suffered during
the test
or
1/5000th
of tho original volume
of the cylinder, which-
ever is less.
(2) For cylinders for low pressure non-corrosive liqucfl-
able gases :
(i) The cylinder shall be subjected to hydrostatic test
in accordance with IS:5844 by non-jacket method
except that the volumetric changes during tho test
need not be measured,
(ii) The test pressure shall be retained for a period of
not less than 30 seconds. Any reduction in pressure
noticed during this retention period of any leak-
age, visible bulge or deformation shall be treated
as a case of failure in the test.
(3) As soon as the test is completed, the cylinder shall be
thoroughly dried Internally and stall bn clearly stomped on
the neck and with marks and figures indicating the person
by whom the test has been carried out and the date of test,
Code mark of the person by whom the test hns been carried
out shall be registered with tho Chief Controller.
43. Condemning of cylinders.—(1) Any
cylinder
which
fails to pass periodic examination or test or which loses in
its tare weight by over 5 per cent or which for any other
defect is found to bo unsafe for use shall be destroyed
by
flattening it as a whole or after bcinrt cut into pieces in inch
a manner that the pieces cannot agnin be joined together by
welding or otherwise to form a cylinder.
(2) All markings on the cylinder shall be defaced before
it Is destroyed.
(3) History sheets of such cylinders shall be closed and
Vepi on record for a period of one year. Reports of the
details of such closed history card* shall be sent to the Chief
Controller, In writing, on the 1st January, April, July and Octo-
ber every year.
(4) A cylinder has been used for the freneration of nnv
gas or for any purpose other than storage, "transportation and
use of compressed sas shall be deemed to have been con-
demned and unstable for such use as a cylinder within the
meaning of these rules.
44. Records of test.—Full record of cylinders examined
and tested at any testing station shall bo maintained itfvinR
the following particulars, namely :—
(a) Name of the manufacturer and the owner of the
cylinder.
(b) Rotation Number.
(c) The specification to which the cylinder conforms.
(d) Data of original
hydrostatiefhydrostatfe
stretch
test.
fe) Test reporti and certificates furniihcd by the manu-
facturer, If available.
(f) Test pressure.
fg) Maximum working pressure.
(h) Water capacity
(i) Tare weight.
(j) V.vintlon, if any, in the tare weight marked on the
cylinder and actual tare weight.
(k) Condition of cylinder shell.
(1) Nam© of gas.
Cm) Typo of valve fitted, and
(n) Remarks, if any.
The above particulars shall form tho history card for each
cylinder and all changes from time to time shall bo indicated
therein.
CHAPTER VI
Dissolved Acetylene gas cylinders
45. Additional requirements for dissolved acetylene cylin-
ders.—Dissolved Acetylene gas cylinder shall comply with
the following additional provisions, namely :—
(i) The porous substance shall fill as
completely as
possible the cylinder into which the acetylone is com-
pressed.
(ii) The porosity of the substance thall not exceed 92
per cent and in no case shall be less than 75 per
cent.
(iii) Any solvent used shall not be capable of chemical
reaction with the acetylene gas or with the norous
substance or with the metal of the cylinder.
(iv) If acetone is used as a solvent it shall comply with
the requirements of IS: 170, The quantity of acetone
including the gas in solution shall be such that the
cylinder meets the requirements of additional tests
specified in TS:7312.
The maximum amount of acetone filled in a cylinder fhall
be proportionate to the porosity of the porous mas? and the
volumetric capacity of the cylinders in the following scale:
Porosity Per cent
Over 15 upto and including 80
Over 80 upto and including 83
Over 83 upto and including 87
Over 87 upto and including 90
Over 90 upto and including 92
Maximum Acetone con-
tent In per cent of wate;
capacity
of
cylinder,
by volume
For
cylinders
having
nominal
water
capacity
not
exceeding
9 litres
34.8
37.1
38.5
38.5
41.8
For
cylinders
having
nominal
water
capacity
exceeding
9 litres
36.2
38.6
40.0
42.0
43.4
(v) The valves of the cylinders shall not contain more
than 70 per cent copper in their composition.
(vi) The pressure In the cylinder shall not exceed 16K#f|
Cms at a temperature of 150°C.
(vii) Every cylinder shall before being filled with poroui
mass be tested by hvdrostatic pressure to a pressure
of not less than 60Kuf\Ctn2. This pressure may
be reduced to 53 KgflCm2 if the cylinder ia fitted
321
with fuiible plug. No cylinder which shows a per-
manent atretch in excess of 7-1/2 per cent of me
total stretch suffered during hydrostatic stretch test
shall bo allowed.
(viii) The safety relief devices if fitted, shall operate at a
pressure of 53 Kgf/Cm2 or at a temperature of
100°C + 4°C —2"C
(IX) Every cylinder shall have
permanently and conspi-
cuously marked upon it or upon a brass plate sol-
dered to it the name of the manufacturer and the
words "Acetylene properly compressed into porou3
substance" and shall bear the following markinss,
namely :—
(a) Serial number and identification of manufacturers;
(b) Number of the standard;
(c) Test pressure;
(d) The date of hydrostatic stretch test with cock
mark of the place where the test was carried
out;
(e) Date of filling of porous mass;
(f) Water capacity;
(g) A symbol to indicate the nature of heat treat-
ment;
(h) Identification of poious mass;
(0 Tare weight;
(j) Inspector's official mark; and
(k) Maximum gas capacity.
46. Restriction on filling of dissolved acetylene cylinders.—
No person shall charge with acclylene any cylinder unless
he is in possession of full particulars and the previous histoiy
of such cylinder and has otherwise assured himself that the
cylinder complies with the requirements of these rules.
47. Examination of dissolved acetylene
cylinders
before
filling.—Whenever a cylinder is charged with acetylene, it
shall be subjected to a thorough visual examinations, if the
history of the cylinder shows that it has not been subjected
to such an examination within the previous two years and tit
the same time the valves will be removed and the condi-
tions of the porous substance at the neck of the cylinder
ascertained. This period of periodical examination shall be
one year
in case the cylinders are filled with loose porous
mass.
48. Licence for compression of acetylene.—The comores-
«ion of the acetylene gas into a cylinder shall be carried out
only On such premises a* are licensed by the Chief Controller.
49. Record of dissolved acetylene cylinders.—Each firm
charging acetylene in cylinders shall keep a record of every
cylinder charged by it. This record shall give the following
information, namely :—
(a) the date of each charging of the cylinder ;
(b) the dates upon which solvent has been added;
(c) the dates upon
which the
cylinder has
been
thoroughly examined as provided in rule 47, the
results of each such examination and the name of
the person carrying out such examination, and in
the case of cylinders first issued by the firm, the
tare weight of the cylinder including porous subs-
tance and acetone or other solvent, the nature of
the solvent and the maximum pressure allowed in
the cylinder.
The record shall be open for inspection of the Chief Con-
troller and the Controller of Explosives.
50. Labelling of dissolved acetylene cylindois—A warn-
ing label attached to every dissolved acetylene
cvfinder
shall. In addition to the particulars given in sub-rule (2)
erf rule 9 bear the following additional particulars, namely :—
fa) date of last filling of g^s ia the cylinder ; and
(b) weight of jae filled.
CHAPTER VII
FILLING AND POSSESSION
51. Licence for filling and possession.—(i) No person
shall liil any cylinder with compressed gas and no cylinders
idled with compressed gas shall be possessed by uny one
except under and in accordance with tJio conditions of a
kcencc gi tinted under these rules.
(2) The licensee shall be responsible lor all operations
connected witri the filling and possession oi cylindeis in the
licensed premises.
52. No licence needed for filling and possession in certain
cases.—Notwithstanding anything contained in rule M, no
licence shall be necessary for :•—
,(a) Ming small quantity of compressed gaa from one
cyUnder to another for the purpose of any experi-
ment or test of for bieathing;
(bj possession of any cylinder filled with a compressed
gus by a carrier or other person for the purpose
of transport in accordance with the provisions of
these rules;
(c) possession of cylinder filled with :—
(i) liquefied petroleum gas when the total
quantity
of gas does not exceed 100 kg. at any
one
turns;
(u) auy other flammable but non-toxic gas when the
total number of cylinders containing such
gas
does not exceed 15 or the total weight of gus
does not exceed 125 kg. whichever is less, at any
one time;
(ii) any non-flammable non-toxic gas when the total
number of such cylinders docs not exceed 50
at any one time;
(iv) any toxic gas when the total quantity of
such
cylinders does not exceed 5 at any one time;
(v) acetylene gas contained in cylinders in dissolved
state when the total quantity of such cylinders
docs not exceed 15 at any one time.
53. Restriction on
filling.—No
person shdl
fill
any
cylinder with any compressed gas unless such a cylinder
and its valve or other fittings :—
(a) are of approved type and standard ag per rule 3
and has been specifically approved for filling by the
Chief Controller;
,(b) have passed the examination and test specified in
rules 41 and 42 ;
(c) conform to the provisions of rules 4, 5, 6, 7 and 8.
54. Working pressure and filling ratios.—(1) The work-
ing or internal pressure in any cylinder charged with a
permanent gas shail not exceed two-third of the test pree»3uro.
(2) Cylinders charged with liquefiable £<ises shall not bo
filled in excess of the filling ratios specified in IS : 3710
for low pressure liquefiable gases and IS : 8866 for high
pressure liquefiable gases.
55. Prior approval of specification and plans of premises
proposed to be licensed.—-(1) Every
person
desiring to
obtain a licence to fill and store auy compressed gas in
any cylinder shall submit to the Chief Controller :—
(i) specifications and plans drawn to scale in triplicate
clearly indicating—
(a) the manner in which the provisions prescribed
in these rules will be complied with;
(b) the premises proposed to be licensed, the area
of which shall be distinctly oolourej or other-
wise marked;
(c) the surrounding area lying within 100 metres of
the edfie of all facilities which are
proposed
to be licensed.
(Ii) A scrutiny fee of rupees fifty paid in the manner
prescribed in rule 72.
322
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)3
(2) If the Chief Controller after scrutiny of the specifi-
cation* and plan) and after making such inquiries as lie
deems fit, is satisfied that compressed gas will oe filled and
stored in the premises proposed to be licensed, according
to the provisions of these rules, he shaJ return to tho
applicant one copy each of all the specifications and plans
signed by him conveying his
sanction subject to
such
conditions as he may specify.
56. Grant of licence.—A licence under these rules may
be granted by the Chief Controller on
payment of the
fees specified in Schedule V.
57. Application for licence.—A person wishing to obtain
or renew a licence under these
rules shall submit
un
application, in writing, to the Chief Controller—
(a) in Form 'B*. if the application is in respect ol n
licence in Form T>'. and
(b) in Form 'C, if the application is in respect ol a
licence in Form 'E', or Form 'F.
38. Period for which licences may be granted or rene-
wed—(1) A licence in Form *D' for the import of cylinders
fiUed or intended to be filled with compressed gas may be
granted for such period as the Chief
Controller may
deem necessary subject to a maximum of one year.
(2) A licence in Form 'B1, or Form 'F' for filling and
storage of compressed gas respectively granted or renewed
under these rules shall remain in force till the 31st day of
March of the year upto which the licence is granted or
renewed subject to a maximum of three years.
(3) Notwithstanding anything contained in sub-rule >(2),
the Chief Controller, where he is satisfied that a licence
is required for a specific work which is not likely to last
upto the 31st day of March of
the year upto
which
the licence is granted or renewed may grant or renew a
licence for such a period as is necessary.
59. Particulars of licence.—(1) Every licence
granlcil
under these rules shall be subject to the conditions specified
therein and shall contain all the particulars
-which are
contained in the form specified under these rules.
(2) One copy of the plan or plans
for the licensed
premises signed in token of approval by the Chief Con-
troller, shall bo attached to the licence which shall form
part of such a licence, and an identical copy shall be filed
for record in the Office of the Chief Controller.
60. Prior approval necessary for alteration in the licen-
sed premises.—(1) No alteration shall be carried out in the
licensed premises until the plan or plans showing such
alterations has been approved in writing by the Chief Con-
troller.
(2) A person wishing to carry out anv alteration in the
licensed premises shall submit to the Chief Controller.
(i) three copies of a properly
drawn plan of 1be
licensed premises snowing In distinct colour
or
colours the proposed alterations aitd the
reasons
therefor;
(ii) a scrutiny fee of rupees ten paid in the manner
prescribed in rule 72.
(3) If the Chief Controller, after scrutiny of the plnn
showing the proposed alteration and after
making such
enquiries
as
he
deems
fit,
is
satisfied
that
the
proposed^ alteration may be carried out, he shall return
to the licensee one copy of the plan signed by him and
conveying his sanction subject to such condition or condi-
tions as he may specify.
(4) The holder of the licence shall apply to the Clu>f
Controller for the amendment of the licen-e as soon as
the sanctioned alteration has been carded out.
(5) No additions or alterations carried out in tbe licensed
premises sanctioned by the Chief
Controller shall he
brought into us© unless the licence is received by the licensee
duly amended.
«1. Amendment of licence—CD Any lici-nte
granted
under these rules may be amended by the Chief Controller.
(2) The fee for amendment of a licence shall be rupees
ten plus the amount, if any, by which the; fee that would
have been payable if the licence had originally been isstietf
in the amendment form exceeds the fee originally paid tor
the licence.
(3) A licensee who desires to have his licence amended
shall submit to the Chiel Controller—
(i) an application duly filled in and signed in Form 'B'
if the licence has been granted tor the import of
compressed gas cylinders and in foim 'C if the
licence is granted to fill and store any compressed
gas in cylinders;
(ii) the licence sought to be amended together
with
the approved plans attached to it;
(iii) where anv alterations in the licensed premises ha\e
been carried out, three copies of the
properly
drawn plans showing the alterations
sanctioned
under rule 60 by the Chief Controller.
(iv) fees for the amendment of the licence as specified
in sub-rule ,(2).
62. Renewal of licence.—-(1) A licence may be rene-
wed by the Chief Controller.
(2) Every licence granted in Form
'12' and Foim 'F'
under these rules, may be renewable for tluee
financial
years where there has been no contravention of the provi-
sions of the Act or any rules framed thereunder or of any
condition of the licence so renewed.
(3) Where a licence which has been renewed for more
than one year is surrendered before its expiry, the renewal
fee paid for the unexpired portion of the licence shall be
refunded to the h'censec provided that no refund of renewal
fee shall be made for any financial year diuins
which
tho Chief Controller receives the
renewed licence
for
surrender.
(4) Every application for the renewal of a licence shall
be accompanied by the licence which is to be
renewed
together with approved plans attached to the licenc;. and
the renewal fee.
(5) Every application for the renewal of a licence shall
be made so as to reach the licensing
authority at least
thirty days before the date on which it expires and if tbe
application is so made, the licence shall be deemed to be
in force until such date as the Chief Controller renews
the licence or until an intimation that the renewal of the
licence is refused has been communicated to the applicant.
(6) Where the renewal of a licence is refused, the fee
paid shall be refunded to the licensee after
deducting
therefrom the proportionate fee for the period
beginning
from the date from which the licence was to he renewed
upto the date on which renewal thereof i.s refused.
(7) The same fee shall be charged for tlie renewal of
a licence for each financial year as for the grnnt thereof :
Provided that—
(i) if the application with accompaniments required
under sub-rule i(4) is not received within
the
time specified In sub-rule (5), the
licence shall
be renewed only on payment of a fee amounting
to twice the fee ordinarily payable ;
fii) if such an application with
accompaniments is
received by the Chief Controller after the date
of expiry but not later than thirty days from
the date of expiry, the licence may,
without
prejudice to any other action that may be taken
in this behalf, be renewed on payment of twice
the fee ordinarily payable.
Provided further that Jn the case of an application
for the renewal of a licence for ,i period of more
than one financial year at a lime, the fee pres-
cribed under the first proviso, if payable, shall be
paid only for the first financial year of renewal.
(8) No licence ihall be renewed if the
anplication for
renewal is received by the Chief Controller atler tliiry days
of the date of its expiry.
323
63. Refusal of licence.—(1) The Chief Controller shall,
while refusing to grant, amend, renew a jiceucc, record his
reason* for such refusal in writing.
(2) A copy of the order containing the reasons for such
refusal shall be given to the applicant on payment ot a fee
of rupees five paid in the manner prescribed in rule 72.
64. Suspension and Cancellation of liccm^e.- (1)
Every
licence granted under these rules ihiall be hiible to be sus-
pended or cancelled by an order of the C hief Conti oiler
for any contravention of the Act or oE any rules
framed
thereunder or of any condition contained in such licence,
or by an order of the Central Government if at any time
the continuance of the licence in the hands of the licensee
is deemed objectionable, provided that—
(i) before suspending or cancelling n licence
under
this rule, the holder of the licence shall be given
an opportunity of being heard;
(ii) the maximum period of suspension
shall not ex-
ceed three months; and
(hi) the suspension of a licence
shall not debar
Ihe
holder of the licence fiom applying for
its re-
newal
in accordance
with
the
provisions
of
rule 62.
(2) Notwithstanding anything contained in sub-rule (1)
an oportunity of being heard may not be given to the holder
of a licence before his licence is suspended or cancelled in
cases—
(I) whero the licence is suspended by the Chief Con-
troller as an interim measure for violation of any
of the provisions of the Act or these rules, or of
any condition contained in such licence or in his
opinion such violation is likely to cause imminent
danger to the public;
Provided that where a licence is so suspended, the Chief
Controller shall give the holder of the licence an
oppoi tunity of being heard before the order
of
suspension is confirmed;
(ii) where the licence is suspended or cancelled by the
Central Government, if that Government considers
that in the public interest or in the interest of the
security of the State such opportunity should not
be given.
(3) Tbc Chief Controller or the Central Government sus-
pending or cancelling a licence under sub-iule (1), shall re-
record its reasons fpr so doing in writing.
65. Procedure on expiration, suspension or cancellation of
licence.—-A person licensed to fill or store compressed gas
shall, on the expiration, suspension or
cancellation of his
licence, forthwith give notice to the Chief Controller of the
nature and quantity of compressed gas in his possession and
shall comply with any directions which the Chief Controller
may give in regard to its disposal.
66. Appeal.—(1) An appeal shall
lie with the Central
Government against any order passed by
the Chief Con-
troller refusing to grant, amend or renew a licence or can-
celling or suspending a licence.
(2) Eveiy appeal shall be in writing and shall be ac-
companied by a copy ol the order appealed
against and
shall be presented within sixty days of the order pused.
67. Procedure on death or disability of licensee.--(l) If
a licensee dies or becomes insolvent or mentally incapable
or is otherwise disabled, the person carrying on the busi-
ness of such licensee shall not be liable to any penalty of
confiscation under the Act or these rules for exercising the
powers granted to the licensee dming such time
as may
reasonably be required to allow him to make an applica-
tion for a new licence in his own name for the unexpired
portion of the original licence in respect of the year
in
which the licensee dies or becomes insolvent
or mentally
incapable or is otherwise disabled :
Provided that nothing in this sub-rule shall be deemed to
authorise the exercise of anv power under this sub-rule by
any person after the expiry of the puiiud of the licence.
(2) A fee of rupees five shall be charged
for a new
licence for the unexphed portion of the original
licence
granted to any person applying for it under this rule and
the fee shall be paid in the manner presenbed in rule 72.
68. Loss of licence.—Where a licence granted u-nder these
rules is lost or accidentally destroyed, a duplicate may be
granted on submission of a copy of the plan or plans iden-
tical with those attached to the licence and on payment of
a fee of rupees ten paid in the manner
prescribed in nile
72.
69. Production of licence on demand. —(1) Every person
holding or acting
under a licence granted under
these
rules shall produce it,
or
on authenticated copy of it,
at
the place to which the licence applies, when called upon to
do so by any of the officers specified in rule 77,
(2) Copies of any licence may, for the purposes of this
rule, be authenticated by the authority which granted
the
]Jcence—
(a) on payment of a fee of rupees five in the manner
prescribed in rule 72 for each authenticated copy;
and
(b) on the submission of a copy or copies of the plans
identical with the approved plan or plans attached
to the licence.
70. Procedure on reports of infringement.—The District
Aulhoiity shall inform the Chief Controller oE the action
taken by him on any reports, of infringement of the Act or
of these rules which the Chief Controller
may make to
him.
71. Executive control over authoiities,—Every authority,
other than the Central Government, acting under this Chan-
ter shall perform its duties subject to the control of the
Central Government :
Provided that nothing in this rule shall be
deemed to
affect the powers of executive control of (he Chief Con-
troller over the officers subordinate to him.
72. Payment of fee.—All fees payable under these rules
shall be paid through crossed demand draft diawn on any
Nationalised Bank in favour of the Accounts Officer, Pay
& Accounts Office, Department of Explosives, Nagpur.
In
case, however, the amount does not exceed K.s. 100 (rupees
one hundred) the payment may be made by cash money
order, postal order or cheque drawn on a local Bank.
CHAPTER VIII
73. Power to exempt.—Tf the Chief Controller is satisfied
that in respect of any cylinder or class of cylinders or any
mode of conveyance any of the requirements of these rules
may be safely suspended or modified he may, by Written
order, authorise such suspension or modification for such
period and under such condition us he mav think fit. Any
such order may be revoked at any time.
CHAPTER IX
Accidents and Inquiries
74, Notice of Accidents.—(1) The notice of an nccident
required to be given under sub-section (1) of section 8 of
the Act shall be given forthwith—
(i) to the Chief Controller bv Express telegram (Tele-
graphic
Address—Explosives, Nagpur)
followed
within 24 hours by a letter giving particulars
of
the occurrence; and
(ii) to the officer in-charge of the nearest Police Station
by the quickest route.
(2) Pending the visit of tb= Chief Controller, or his re-
presentative, or until instruction is received from the Chief
Controller that he does not wish to make any further in-
vestigation or inquiry, all wreckage and debris shall be left
untouched except in so far as its removal may be necessary
for the rescue of the persons injured and recovery of the
bodies of uny persons killed by the accident or in the case
of railways, for the restoration of through communication.
324
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i)]
75. Inquiry into accidents.—(1)
Whenever
a
District
Magistrate, a Commissioner of Police or Magistrate subordi-
nate to a District Magistrate (hereinafter in
this rule
referred to as the
Magistrate) holds an inquuy under
sub-section (1) of section 9 of the Act, he shall adjourn
such an inquiry
unless the
Chief
Controller
or
an
officer nominated by him is present to watch the proceedings
or the Magistrate has received writien Information
from
the Chief Controller that he does not wish to send a re-
presentative.
(2) The Magistrate shall, at least 14 days before holding
an adjourned inquiry, send to
the Chief Controller notice
in writing of the time and place of holding the adjourned
inquiry.
(3) Where an accident has been attended with loss of
human life, the Magistrate, may before the inquiry is ad-
journed under sub-rule (1) take evidence to identify any
bodies and may order the internment thereof.
(4) The Chief Controller or his representative shall be
at liberty at any such inquiry to examine any witness.
(5) Where evidence is given at an enquiry of any neglect
as having caused or contributed to the explosion or. acci-
dent or of any defect in or about or in connection with any
Installation or any vehicle appearing to the Magistrate
or
Jury to require a remedy and the Chief Controller or the
officer nominated by him is not present at the enquiry, the
Magistrate shall
send to the Chief Controller notice
in
writing of the neglect or defect.
76. Inquiry into more serious
accidents.—(I) Whenever
an inquiry is held under section 9A of the Act, the persons
holding such inquiry shall hold the same in open Court
in such manner and under such conditions
as they may
think most effectual for ascertaining the causes and circum-
stances of the accident,
and enabling them to make
the
report under this rule :
Provided that where the Central Government so directs
the Inquiry may be held in camera.
(2) Persons attending as witnesses
before
the
enquiry
Court shall be allowed such expenses as would be allowed
to witnesses to attending before a Civil Court subordinate
to the High Court having jurisdiction in the place where
the inquiry is held and in case of any d^puto as to the
amount to be allowed, the question shall bo referred to the
local Magistrate, who, on a request made by the enquiry
officer, shall ascertain and certify the proper amount
of
such expenses.
(3) All expenses incurred hi or about an inquiry or in-
vestigation under this rule shall be deemed to be part of
the expenses of the Department of Explosives in carrying
the Indian Explosives Act,
1884 (4 of 1884) into execu-
tion.
CHAPTER X
Powers
77. Dangerous practices.—(1) If in any matter which is
not provided for by any express provision of, or condition
of a licence granted under these rules, the Controller
of
Explosives finds any compressed gas filling station
or a
storage place, where a cylinder is being filled or possessed,
or any part thereof or anything or practice therein or con-
nected therewith or with the handling or transport of com-
pressed gas cylinder?, dangerous or defective, so as, in his
opinion, to tend to endanger the public safety or the bodily
safety of any person, such Controller may by an order in
writing require the occupier of such filling station or stor-
age place or the owner of the cylinder to remedy the same
within such time as may be specified in the order, and the
said occupier shall carry out the orders within the specified
time.
(2) Where the occupier or owner objects
to an order
made under sub-rule-
(1), he may appeal to
the Chief
Controller within the time specified in the order for com-
pliance with it, and the order of the Chief Controller on
such appeal shall bo final.
(3) Every appeal preferred under sub-rule (2) shall
be
in writing and shall be accompanied by a copy of the order
appealed against and shall be mjide within a period of 30
day» from the date of the order appealed against
(4) If the occupier or owner fails to comply with
an
order made under sub-rule (1) within the time specified in
it or, where an appeal is preferred under sub-rule (Jd, fails
to comply with the order of the Chief Controller thereon
within the time fixed in such order, he shalj be deemed to
have committed a breach of this rule,
78. Powers of inspection, search, seizure, detention
and
removal.—(1) Any of
the officers, specified in
the first
column of the Table below may exorcise the
powers speci-
fied in sub-section (1) of section 7 of the Act in the area
specified in the corresponding entry in the second column
of that Table.
TABLE
1.
2.
3.
4.
5.
Officers
The Chief Controller, Deputy
Chief Controllers, Controllers,
Deputy Controllers and Assis-
tant Controllers of Explosives.
All District Magistrates
.
All Magistrates subordinate to
the District Magistrate.
The Commissioner of Police and
all Police Officers of rank not
below that of an Inspector.
All Police Officers of rank not
below that of Sub-Inspector.
Area
The whole of India.
Thotr
respective
dis-
tricts.
Their respective jurisdic-
tion.
lu Presidency town or
their suburbs.
The respective area over
which their authorily ex-
tends.
Provided that the powers
of removal
and destruction
under clause (d) of sub-section (1) of section 7 of the Act
shall not be exercised by any Magistrate or Police Officer
except under and in accordance with the instructions of the
Chief Controller, Deputy Chief Controller, Controller or
Deputy Controller or Assistant Controller of Explosives.
(2) Every facility shall be afforded to the officers speci-
fied hi sub-rule (1) to ascertain that these rules are
being
duly observed.
SCHEDULE I
tSoe rule 3(1)]
TYPES AND STANDARDS OF CYLINDERS AND VALVES
A. CYLINDERS :
1. Austrian origin :
Seamless Steel cylinders manufactured by M/s Jos. Heiser
of Austria—inspected and certified by Bureau Veritas conform-
ing to specifications BS : 399, BS : 400, BS : 1045, Home
Office
'3'
and
T \
DOT: 3A : 1800
ond
above,
DOT: 3AA : 1800 and
above for
permanent gases and
BS : 401, BS : 1287, BS : 1288, DOT : 3A/DOT : 3AA for
liquefiable gases.
2. Czechoilovakian Origin :
Seamless Steel cylinders manufactured by M/s Vitkovicke
Zclezarny Klementa Gottawalda of Czechoslovakia inspected
and certified by Inspekta Praha conforming to specifications
BS : 399 for permanent gases and BS : 401, BS : 1287 for
liquefiable gases and CSN specification with steel conforming
to CSN : 13142.6 for permanent high pressure liqueflable gases
and with steel conforming to CSN : 11353.1 for low pressure
liquefiable Bases.
3. Hungarian origin :
Steel cylinders manufactured by Cscpel Steel and Metal
Works, Budapest—inspected and certified by Boiler Coinmis-
sionary Chief
Department of
Government Supei vision
for
325
Energetics and Security of Technical Energy, Budnpest con-
forming to 'pecification MSZ: 2665-53 with Chrome Alloy
sticl designr.ted as Cr. 135 having 200 mm. nominal diamrter
with 5^sm. minimum wall thickness for peimanent and lique-
fiable gases.
4. Indian origin :
Welded Steel
cylinders manufactured
by Shri
Ambica
Cylinder Manufacturing Co. Ahmedabad, Apeejay Structural
Ltd., Rajbandh, District Burdwan (West Bengal), Bharat Pumps
and Compressors Ltd., Nairn, Allahabad, Gannon Dunkerley
and Co. Ltd., Bombay, Hindustan General Industries Limited,
Nangloi, Dclhl-41, Hyderabad Allwyn Metal Works Limited,
Hyderabad,
Ideal
Engineers
Hyderabad
Private
Limited,
Hyderabad, Indian Gas Cylinders, Faridabad, Kosan Metal
Products Pvt. Ltd., Bombay, Martin Burn Ltd., Calcutta—
inspected and certified by ISI or any other appropriate authority
approved bv the Chief Controller, conforming to IS : 3196,
IS : 7142, TS : 7680 and IS : 7681 specifications for low pres-
sure liqueflablo gas service.
(b) Seamless manganese steel cylinders for permanent and
high pressure Hquefiablo gases conforming to IS : 7285 manu-
factured by Bharat Pumps
and Compressors Ltd., Naini,
Allahabad—inspected and certified by ISI.
5. Italian origin :
Steel cylinders manufactured bv M/s Acclaieria E. Tubiflcio,
Di Brescia—inspected and certified by Bureau Varitas con-
forming to specifications DOT : 3AA : 1800 and above for
permanent gases and DOT : 3AA for Hquefiable gases.
6. Japanese origin :
fa) Steel cylinders manufactured by M/s Showa Koatsu
Kogvo Co. Ltd.,—inspected and certified by Com-
pany's own Inspector or KHK or Lloyd's or Bureau
Veritas
conforming
to
specifications
BS: 399,
BS: 400,
BS : 1045,
Home
Office
'S* &
T,
DOT: 3A : 1800 and above, DOT : 3AA : 1800 and
above, JIS : B : 8241 : 1968 relating to Manganese
Steel for permanent pases and BS : 401, BS : 1287,
BS : 1288,
DOT : 3A/DOT : 3AA
for
Hquefiable
gases.
(b) Steel cvllnders manufactured by M/s Sumikin Kiko
Co. Ltd../Sumitomo Metal Industrie! Ltd., or NIhon
Koatsu Yokl—inspected and certified by KHK or
I lovd'a or Bureau Veritas conforming to specifica-
tions BS : 399, BS : 400. BS : 1045, Home Office 'S'
and
T ,
DOT: 3A : 1800
and
above,
DOT : 3AA : 1800 and above, JIS : B : 8241 : 1968
relating to Manganese Steel for permanent pases and
BS:401.
BS:1287,
BS : 1288,
DOT:3A/
DOT : 3AA, for liquefiable gases.
(c) Steel cylinders manufactured bv M/s Totskuka High
Pressure Gas Cylinder Co. Tokyo, Tapan, Kanto
Koatiu Yoki Manufacturing Co. Ltd., Tapan and
Tokai High Pressure Cylinder Co. Ltd., Japan—ins-
pected amT certified by KHK or Lloyd's or Bureau
Veritas conforming to specifications DOT: 3A : 1800
and above and DOT : 3AA : 1800 and nbove for
permanent gases
and DOT : 3A/D0T : 3AA
for
Ifquefiable gases.
7. Polish origin :
Seamless steel eviinders manufactured by M/s Prema Mflmet,
Poland made to PN-69222, BS : 1045 and BS : 1288 specifica-
tions, inspected and certified bv Polish Government Inspecting
Authority for permnnent and Hquefiable gases.
8. Russian origin:
Steel cylinders manufactured bv approved manufacturers in
TT.S S R.—inspected pnd certified bv appropriate nuthoritv con-
forming to specifications GOST : 949 : 57 and GOST : 949-73
for permanent and Hquefiable gase«.
9 TJ.K. origin :
(a) Steel cviinden manufactured
by M/s Chesterfield
Tube Co. Ltd., of U.K.—Inspected and certified bv
Company's own Inspector or Lloyd's conformina to
specification BSS : 399, BS : 400, BS : 1045, Home
Office; 'S' and T', for permanent ^ases and BS : 401,
BS : 1287, BS : 1288 for liquefiable gasrs.
(b) Aluminium Alloy cylinders manufactured by M/s
Luxfer Limited-—inspected and certified by National
Vulcan Engineering Insurance Group Ltd,, conforming
to specifications HOAL-3 as per drawings No. 102017|
ZAD|591,
102034|ZAD|583.
15204R|ZAD|585.
152O681ZAD|586 and 176O12|ZAD|2083.
10. USA origin :
Steel cylinders manufactured in U.S.A.—Inspected and certi-
fied bv
appropriate authority,
conforming to
specifications
DOT : 3A/3AA for permanent and liquefiablo gases.
11. West German origin :
Steel cylinders manufactured bv Mannesmann of West Ger-
many—inspected and certified by Llovd's or Bureau Veritas
conforming to specifications BS : 1045, Home Office 'S* and
"T for permanent gases and BS : 401, BS : 1287, BS : 1288
for liquefiable gases.
12. Yugoslavian origin :
Steel cvllndem manufactured bv Slavonski Partisan, Slavonski
Brod
of
Yuooslavia—inspected
and
certified
bv
Yugo-
slavian State Authority viz. Stenm Boiler Inspection Authority
or Llovd's conforming 1o snecifidtiorts BS : 1045. for perma-
nent gases and BS : 401. BS • 1287, BS : 1288 fnr liquefiable
cases and DGVO DIN 4664 for permanent and high pressure
liquefiable gases.
B CONTAINERS :
1. Indian origin :
Ca) Chlorin- Tonne containers conforming to BS : 1500 :
Pnrt I Cinss T Vessels, manufactured bv S/shri Ambica
Cylinder ManufpcrnrinR Cci Ltd , Ahmedabad, Bharat
Heavy Plntrs—Vessels ltd , ViRakhanatnam. Indian
Suear anrf General Engineering Corporation. Yamnnft-
naRMi' (Harvfina), Kaveri Structural. TiruchirapalH,
T.nrsen and Toubro Ttd.. SnkI Vlhar Road, Bombay.
Annp Fnoirieerina Co. Ltd., Ahmedabad, inspected
and certified bv Llovds.
(b) Tonne containers for low pressure Hqueflabie gas
service conforming to BS : 1500: Pnrt I
: Class T
vessel, manufactured bv M/s Central India Machinery
Manufacturinn Co., Inspected and certified by Bureau
Veritas.
(c) Tonne containers for low pressure Hqnefiable pas
servio conforming tn BS : 1515. manufactured bv
M/s T.arscn and Toubro Ttd. Sakl Vihar, Bombay
and inspected and certified by Lloyds.
2. Japanese origin :
Chlorine tonne containers conforming to BS : 1500 manu-
factured by Showa Koatsu Kogvo Co. T td .—inspected and
certified bv Company's own Inspector or KHK or Lloyd's or
Bureau Veritas.
3. U.K. origin :
Chlorine tonne containers conforming tn BS : 1515 :Part T ;
1965 manufactured bv Thon Thompson Horn-lev Bridge Ltd.,
Inspected ann" certified by the Ocean Accident and Guarantee
Corporation Ltd-
4. U.S.A. origin :
Chlorine tonne containers
conforming to DOT : 106A :
500-X manufactured bv Columbiana Bniier Co., Inspected and
certified by appropriate authority In U.S.A.
C. DISSOLVED ACETYLENE GAS CYLINDERS :
1. Australian origin :
Cylinders manufactured by M/s Jos Heiser Vormali J. Win-
ters Sohrt. Austria to BS : 401 specification and filled with
Covne 90-92 per cent porous mass—inspected and certified by
Bureau Verttaa.
3:fi
THE GAZElTJi OF INDIA: EXTRAORDINARY
[P.vi'.r Jl—Sue. 3(i.)|
2. Japanese origin :
Cylinders manufactured bv M/s Kanto Koatsu Yoki manu-
facturing Co.
T.td., and
Japan Coyne
Cylindei Co.
to
IS : 7312 : 1974 filled with monolithic porous mass of 90-92
per cent porosity inspected and certified by Bureau Veritas.
3. Indian origin :
Cylinder* manufactured by Bharat Pumps and Compressors
Ltd., to TS : 7312 specification filled with Monolithic porous
mass 90-92 per cent porosity inspected and certified by I.S.I.
4. Italian origin :
Cylinders manufactured by M/s Acciaieria E. Tubificio Di
Brescia. Italy according to TCC : 8 specification having neck
thread conforming to BS : 341—shell tested at a pressure not
less than 900 p.s.i.g. and filled with Silica Sinlex porous mass
of 90-92 per cent porosity inspected and ceitified by Bureau
Vcritas.
5. UK. origin :
Cylinders manufactured in U.K. to design No. DA. 759 and
specification No. DA2A filled with appropriate porous mass,
inspected nnd certified by British Oxygen Co. Ltd., U.K.
6. LI.S.A. origin :
Cylinders manufactured bv Pressed Steel Tank Company
and Covne International to TCC : 8 specification having neck
thiend conforming to BS : 341—shell tested at a pressure not
less than 900 p.s.i.g. and filled with Covnc 90-92 per cent
monolithic porous mass—inspected and certified by appropriate
authority in U.S.A.
7. Yugoslavian origin :
Cylinders manufactured bv Slavonslci Partisan. SlavonsH
Brod of Yugoslavia to BS : 401 and filled with Silica Sintex 92
per cent monolithic porous mass—inspected and certified by
T loyds.
D. VALVES:
Valves conforming to TS : 3224 specification manufactured
bv the following Approved Manufacturers in Tndfa—inspected
and certified by T.S.T. or appropriate authority as approved by
I he Chief Controller.
Gannon Dunkerley and Company Liquefied netroleum gas
Limited. Bombay.
cylinder valves.
Indian Oxygen Limited, Calcutta. Valves for high pres-
sure
gas
cylinders,
acetylene and liquefied
petroleum gas cylinders.
Kosan Metal Products Private Ltd., Liquefied petroleum gas,
Bombay.
Chlorine
and
Refri-
gerant cylinder valves.
Martin Burn Limited, Calcutta.
Liquefied petroleum gas
cylinder valves.
Ramniklal Jivanlal Kinariwaia and Chlorine/Ammonia cy-
Company, Ahmedabad.
Under valves.
Tekno valves, Calcutta.
Chlorine/Ammonfa/
Freon/Sulphur
Dioxide
cylinder
valves
and
fusible plugs for con-
tainer.
Vanaz Engineers Private Limited, Liquefied
petroleum
Bombay.
gas/acetylene ammonia/
Argon/Butadiene/Carbo n
Dioxide/Chlorine/Ethyl
Chlorlde/Ethylene/Ethy-
leneOxide/Hydrogen /Ma-
fron /Methyl
Bromide/
Nitrogen/Nitrous Oxide/
Oxygen/Sulphur Dioxide
/Fluoro Carbon cylinder
valves.
SCHEDULE II
|See rule 3(2)]
(A) The lest and inspection
certificates to be obtained
from the Inspecting Authority in respect of cylinders manu-
factured in accordance with the approved design and specifi-
cation or Code shall
include the
following particulars,
namely :•—
1. Place and date of inspection,
2. Gas cylinders for
gas.
3. Manufactured by
4. Location at
5. Manufactured for
6. Location for
7. Quantity
8. Sciial Nos. fiom
to
inclusive.
9. Specification lo which the cylinders are manufactured.
10. Size
mm. outside diameter mm
long.
11. Minimum wall thickness
12, Neck end threading as per
specification,
13, Process of
manufacture
(whether spun type, or
billet pierced or welded),
14, Method of heat Ireatmcnt,
15. Design working pressure in Kg/cm? at 15°C or 65°C
us the ease may be.
16. Hydrostatic test'hydrostatic strelch test pressure in
Kg/cm2.
17. Record of Hydrostatic test/Hydrostatic stretch test
with date of test, in respect of each cylinder.
18. Pneumatic lest pressure in Kg/cms.
19. Result of pneumatic test.
20. Tare weight and water capacity of each cylinder.
21. Record of chemical analysis and physical properties of
the steel used in the manufacture of cylinders,
22. Manufacturer's iden'ification marks.
23. Inspector's mark,
24. Markings stamped, on the shoulder of the cylinders,
25. Dated signature
with
stamp
of
the
impeding
authority.
(B) The test and inspection certificates to bs obtained from
the Inspecting Authority in respect of valves manufactured
in accordance with the approved
design and spcification or
Code shall include the following particulars, namely—
1. Manufactured by —•
2. Location at —
3. Manufactured for —
4. Location at —
5. Quantity —
6. Specification —
7. Resulls of inspection —
(a) Valve inlet connection.
(b) Valve outlet connection.
(c) Valve outlet number.
(d) Hydraulic Pressure test,
(c) Pneumatic Proof test.
(f) Tensile strength.
326/1
(jl) Elongation per cent,
(h) Impact strength.
(i) Quantity offered for inspection.
(j) Quantity passed.
(k) Quantity rejected and reasons for rejection .
8. Dated signature with stamp of the inspecting authority.
SCHEDULE III
[Sec rule 3(3)]
Particulars to be submitted by person desirinfl to Fabricate
cylinders, valves and other fittings.
1. Applicant's name and full address.
2. Whether the applicant has manufactured aw unfired
pressure vessel/valve, if yes—
(i) Date from which such
vessels/valves were
manufactured,
(Li) For whom the
pleasure vessels /valves were
fabricated and their approximate numbers.
(iii) Details of the
pressure vessela/valvei manu-
factured.
3. Specification/Codes
proposed to be adopted for the
manufacture of piessure vessels/valves.
4. Organisational set up of the applicant with
specific
reference to
qualifications and experience of the
personnel encaged in the manufacture of pressure
vessels/Valves,
5. Organisational set up of the inspecting personnel en-
gaged by the applicant.
6. Process of manufacture of
pressure vessels /valves,
beginning with raw material
and ending with the
finished vessels /valve*.
1, Quality control checks|tests carried out at each stage
of manufacture of pressure Vessels|valves.
S. (i) Details of the equipment installed for chemical
analysis and mechanical tcstn,
(ii) Details
of
templates/gauges
provided to
check /test.
(.y.i) Steps taken to check the accuracy of testing
and checking equipment, and frequency of such
checking.
9. Equipment available or
carrying out non-destructive
exiimination such as iadiography, Gama ray, ultra-
soni; tests etc.
10. List of machinay provided for manufacturing pleasure
vessels/valves,
J1, Nwntt and address of the independent inspecting au-
thority.
12, Records and certificates of tests :
(i) Proforma of records for various tes's ennird
out Hy the inspecting and certif\ing oigarasation,
vind
(ii) I'rofonaa of tout nnd inspection certificate issued
by the independent inspecting authority.
SCHEDULE IV
LSee rule 39(2)]
FACILITIES REQUIRED FOR CYLINDER TESTING
STATIONS
1. Management
:J.l General
requirements—Personal,
equipment, inspection procedures, recording and organisation
shall be adequate and tie test station will be operated to
give consignment safe operating conditions. The Drocedures
1367 GI/80—6
and testing shall ensure that cylinders which fail* to meet
the requirements and intent of these rules are not returned
into normal service. All personnel shall fully recognise their
individual responsibilities and that the minimum inspectkraal
requirement shall not be lowered for any reason whatsoever.
Note—The area of responsibility shall b c divided into
three separate functions a» indicated below. The numbers of
of personnel employed shall, however, be related to the
quantum) of work.
1.2 Manager—The manager responsible for the working of
the test station shall be properly qualified; bis qualifications
shall include training on the dangers associated with ga£
cylinders, purpose of inspection, test methods, equipment,
test requiicments, and recording of test results, and he shall
have appropriate technical qualification in Mechanical or
Chemical Engineering. He shall also be conversant with the
Codes, Specifications and/or Regulations applying to the
cylinders for which the test station is approved.
1.3 Supervisor—The Supervisor shall possess the following
qunliflcations, namely—
(i) have at least two years experience in the examination
of gas cylinder ;
(fi) be at least 21 years of age ;
(iii) bc conversant with these rules, Codes, Specifications
andI/or Regulations applying to the cylinders for
which the test station is approved.
1.4 Operator —
Personnel conducting inspections and tests shall have
qualifications
and
experience suitable
for
the
work, on which they arc engaged. They shall be
traiDed to understand the dangers associated with
gas cylinders and the purpose and method of
inspection.
2 Equipment —
2 1 Type of equipment —
The test station shall have adequate equipment to
carry out inspection and testinjt of cylinders as
required under these rules.
It ^hall contain—
(0 One set of these rules. Codes, Specification^ and/
or "Regulations anolyirx? tn the cylinders which ihe
test station is ituthoiised to test. All these rules.
Codes, Specifications and/or Regulations shall be
maintained with all current amendments.
(ii) Hydrostatic test apparatus comprising pressuring
equipment pressure P uge nnd volumetric mea-
suiing eonipment in ttccordance with IS : 5844-
Hvdrostatic stretch testing of
compressed pas
cylindeis. The apptirntus shdll be equipped with
at least two 15 cm diameter (minimum) working
pressuie gaiices.
(ii;) Dead-weight pressure piiunc tester of appropriate
pressure riwgt or ;i calibrrted pies<-ure gauge of
15 cm. minimum diameter covering thft appro-
priate pressure range.
(iv) Ex1ra-low vnltuge lumps to permit ntletjuate internal
viewinc of cylinrl-rs rnd other l.itnps necessary
for closed cxnmination of external surfaces,
(v) Straightedges, templates,
miscellaneous tools and
gauges for measurement.
(vf) Weighing equipment, where applicable.
Cvli) One set of Rtandaid test weights for the weighing
machine, stamped by the relevant statutorv autho-
rity.
f\ iii> Adequate cylinder handling equipment,
(ix) Adeauate cylinder draining equipment,
(x) Facilities for internal drying of cylinders,
W) Marking and damping equipment.
326/2
THE GAZETTE OF INDJA: EXTRAORDINARY
[PAKX Jl—SEC. 3(ijJ
2.2 Accuracy —
The accuracy of equipment shall be as follows :—
(i) Hydrostalic test apparatus in accordance with JS :
5844. Volumetric equipment shall be cnpible
of measuring a permanent change in volume of
the cylinder under test of the order of ]/20,000
of its tot;il capacity.
(ii) Weighinjj equipment error not pi eater than zizl-0
per cent.
(iii) Working pressure gauge error not greater thno 1
per cent of the test pressure.
(iv) Calibrated pressure gauge error not greater than
0.25 per cent of the full scale deflection.
2 3 Calibration —
Calibration of equipment shall bo carried out ut periods
not exceeding the following —
(ij Working pressure gauge—3 week«,
(ii) Calibrated pressure gauge—6 months.
fiii) Weighing equipment—checked by test weight daily
when in service.
Civ) Test weights—2 years.
3, Working conditions —
Working condition"! for the test stations shall bo condu-
cive to accurate and safe inspection and testing of
gas cylinders. The test station shall comply wjth
the following conditions :—
(i) It shall have good lighting to permit ready external
examination of gas cylinders, preferably including
natural lighting.
(ii) It shall have adequate \entilation to remove residual
gases from cylinders.
(iii) It shall provide sufficient space to permit safe
working.
(iv) It shall be maintained in a clean dry condition.
4. Condition of cylinders for test :
Cylinders forwarded to the test station for testing shall
have first been emptied of their contents atad then
labelled a« 'empty'. Irrripective of this label all
cylinders oilier than cylinders at the manufacturers
works shall be presumed to contain gas under pres-
sure and the following precautions shall accordingly
be observed :
(i) The cylinder contents shall be released in a safe
manner keeping in mind dangers associated with
the nature of the gas in the cylinder.
Cylinders
which contain or may have been contaminated by
poisonous or ob-noxious substances shall be emptied
only by test stations properly equipped and ex-
perienced to handle the particular
gas. Such
cylindeis shall be clearly labelled that they have
been contaminated.
(ii) Th© valve shall be opened and if no gas escapes
and the port is not visibly blocked, a charge of
low pressure nitrogen or other inert gas shall be
blown into the valve outlet. Discharge of gas
after removal of the nitrogen supply indicated
the cylinder is empty. When no gas discharges
the
valves
shall be
tieated
as
"obstructed".
Where a cylinder has contained poisonous
or
ob-noxious substances, ind the valve is suspected
of being obstructed, the gas shall be released
within an approved appliance
and the valves
shall be removed in such a manner that
the
fjas. escapes without danger to the operator.
(iii) Should the valve be obstructed the content*
of
the cylinder shall be released in a safe manner
as stated in (i) above. Work on cylinders o n -
taining combustible gases shall be carried out in
the open air,
Note :—A suitable method of dealing with a valve in wtich
the spindle cannot be removed is to drill a l//16th
in (1.6 mm) diameter hole with a hand drill
through the valve body to the gas passage 'beluw
the spindle seating. Alternatively, a nne>-tooth
hacksaw may bo used. Drilling or sawtof; must
be stopped immediately upon the first viga of
escaping gas. A continuous jet of water must be
directed on to the cutting tools and the operator
must wear protective clothing.
5. Inspection and test —
The lest station shall adopt procedures which fully comply
with requirements of these rules.
SCHEDULE V
[See rule 2 (xv) and 56)
si.
No.
1.
2.
3.
Form
of
Licence
D
E
F
Purpose for which
granted
To import cylinders filled
or intended to bo filled
with compressed gas.
To fill compressed gas
in. cylinders.
To store compressed gas
In cylinders.
Authority empowered
to grant licence
Chief Controller of Ex-
plosives.
Chief Controller of Ex-
plosives.
Chief Controller of ex-
plosives.
For the first 100 nos. cylinders or part thereof.
Exceeding 100 nos. but hot exceeding 500 nos.
cylinders.
Exceeding 500 nos. of cylinders Rs. 200,00 for
every additional 500 nos. of cylinders or part
thereof.
For each type of gas filled in the plant, namely
(a) toxic, (b) non toxfc and non flammable,
(c) non toxic and flammable, (d) dissolved
acetylene gas, (e) non-toxic and flammable
liquefiable gas other than LPG or (f) lique-
fied petroleum gas, as the case may be.
(i) For toxic gases (permanent as well as lique-
fied).
Exceeding 5 nos. but not exceeding 100
no's, cylinder1!.
Fees
Rupee*
100.00
200.00
500.00
100.00
326/3
si.
No. rt
Form
> of
Licence
Purpose for which
granted
Authority empowered
to grant licence
Exceeding 100 uos. but not exceeding 500
nos. cylinders.
Exceed in g 500 nos. of cylinders, Rs. 200.00
for every additional 500 nos. of cylinders
or part thereof.
(il) For non toxic und non-flammable gases :
(permanent as well as liquefied).
Exceeding 50 nos. but not exceeding 500
nos. of cylinders.
Exceeding 500 nos. of cylinders Rs. 200.00
for every additional 500 nos. of cylinders
or part thereof.
(iii) For non-toxic and flammable permanent
gases :
Exceeding 15 but not exceeding 200 cylin-
ders
Exceeding 200 but not exceeding 500 nos.
of cylinders.
Exceeding
500
nos. of cylinders of
Rs. 200.00 for every additional 500 nos.
of cylinders or part thereof.
(iv> For non-toxic and flammable liquefiablc
gases other than LPG :
Exceeding 125 Kg. but not exceeding 500
Kg.
Exceeding 500 Kg. but not exceeding 1000
Kg.
Exceeding 1000 Kg. but not exceeding
5000 Kg.
Exceeding 5000 Kg. but not exceeding
10,000 Kg.
Exceeding 10,000 Kg. Rs. 200.00 for every
additional 5000 Kg. or part thereof.
(v) For liquefied petroleum gases :
Exceeding 100 Kg. but not exceeding 500
Kg.
Exceeding 500 Kg. but not exceeding 1000
Kg.
Exceeding 1000 Kg. but not exceeding 5000
Kg.
Exceeding 5000 Kg. but not exceeding
10,000 Kg.
Exceeding 10,000 Kg. Rs. 200.00 for every
additional 5000 Kg, or part thereof.
(vf) For acetylene gaa contained In cylinders in
dissolved state :
Exceeding 15 but not exceeding 200 cylinders.
Exceeding 200 but not exceeding 500 nos.
of cylinders.
Exceeding 500 nos. of cylinders Rs. 200.00
for every additional 500 nos. of cylinders or
port thereof.
Fees
Rupees
200.00
100.00
100.00
200.00
100.00
150.00
200.00
300.00
100.00
150.00
200.00
300.00
100.00
200.00
[F.No. 2(ll)/76-MI/MCI]
R.N. CHOPRA. Addl. Secy.
326/4
THE GAZETTE OF INDIA : EXTRAORDINARY
[PART II—SEC. 3fi)]
FORM A
[Sec rule 29(2)]
Declaration to bo made by the Master of a ship carrying cylinders filled witli compressed gas before entering a port or by the ship'-;
agent.
Name of the ship
Description of filled cylinders
True chemical name and
Total quantity carried
Quantity to be landed
Remarks
nature of tho gas i.e.
in the ship
nt port
whether flammable cor-
———
—
-— — — — —
—- —
roslve or toxic.
No. of
Kg. or
No. of
Kg. or
cylinders.
M* of gas
cylinders
Ms of gas
Dated tho d*y of 19
Signature of Master/Ajtent of Ship.
FORM B
(See rules 37 and 61)
Application for the grant/amendment of a licence to import cylinders :
1. Applicant's name
Applicant's age
Applicant's calling
Applicant's address
2. Particulars of storage licence held by :
(i) Number and date of storage licence issued by the Chief
Controller of Explosives.
(ii) Renewed/valid upto
(ill) Capacity of storage as per above licence.
3. Description of the cylinders to be imported :
(i) Number of cylinders ;
(ii) Specification of cylinder* ;
(ilO Manufactured by ;
(iv) Inspected and tested by ;
(v) Specification of tho valves fitted to the cylinder*.
•(vl) Filled with
—
—
(True chemical name of the gas)
*(vll) FUleding pressure at 15"C if filled with permanent gas or dis-
soleved acetylene.
Vviif) Filling ratio, if filled with a liqueflable gas.
(ix) Date of last hydraulic stretch tost.
(x) Rotation numbers of cylinder*.
4. CyHndore proposed to be store at
5. Remarks
Signature of applicant
Date of application
P o s t aj &<idiess of the applicant
Note :—1. Particulars marked with *are not required to be furnished if empty cylinders are desired to be Imported,
2. Manufacturers test and Inspection certificates complete in all respects pertaining to each lot of cylinders and valve
shall accompany this application.
3.
Tn case cylinders are desired to be Imported duly filled with gas, fillers certificates in respect of items 3(vf), (vfl)
and (ix) shall be furnished.
326/5
FORM C
(Sec rules, 37, 61 and 62)
Application for the grant /amendment/renewal ol' a licence to fill and/or store compressed gas in cylinders
D VUTIAIL, Li,led overlcif must be enclosed with this application, if it K for the grunt nf a lure ice m form T." and T".
The replies to be given in this column.
1. Applicant's numc**
—
'
'
~"
~~^
,,
calling
•
• " ""
'
"~ ~~~~
' "
"
,,
Full postal address
—
—
— —
~—
2. Situation of the premises whore compressed gas is to be stored /
filled.
" - - -
S
t
a
(
c
._„„—
_ _
-
- —
District
— — — '
"" "
'
.
.
.
-
Town or village
—
— —— - — —
~~
Nearest Police Station
— — — — — —
—
- -
— — .
—
Nearest Rly. Station
_____—-
— —
•
—
~
}. Nature of each compressed gus proposed to be filled/stored
namely :
(a) toxic (b) non toxic and non-flammable
(c) non toxic and flammable (d) dissolved acetylene gas (e) non ————
— —
•—•
—
—
—
toxic and flammable liquefiable gas other than LPG or (0
liqucdcd petroleum gas.
— — - — —
•—™—•
•
— —
4. Chemical name of each compressed gas proposed to be filled/
stored
"*
~ ' ~" " ™ '
" ~~ ~*
~
' •
5. Quantity of each compressed gas proposed to be filled/stored in
terms of numbers for gases mentioned under items 3(a), 3(b),
——
— • •
— ~
.
%) or 3(d) ; and in terms of Kgs. for gases mentioned under — — •
• ——— • - — —
•
——-
items 3(e) or 3(f)
—
— — —
—
•
6. Nature, chemical name and quantity of oach compressed gas id- ——
—
• • •
-
ready filled/stored in the premises.
- • •—•
—
— — —
7. Number of the licence held for the premises and the full name of • •
————-—
~
——-
the holder of the licence.
— — - •
• • —
— • • •-
™— - — ~ —
I hereby declare that the statements made above have been checked up by me and arc true and I undertake to abide by the norms
and conditions of the licence which will be granted to me.
Date of application :
Signature and designation of the
applicant
••Where the application is made on behalf of a Company, the name and address of the Company and trio name of the Manager or
Agent should be given and the application should be signed by him.
Every chan gc in the name of the Manager or Agent shall
be forthwith intimated to and his specimen signature filed with licensing authority.
DOCUMENTS REQUIRED TO BR SUBMITTED WITH THIS APPLICATION FOR A LICENCE IN FORM 'I..' AND 'F'.
(i) Four copies of specification and plans approved under rule 55.
(NOT REQUIRED FOR RENEWAL OF A LICENCE WITHOUT AMENDMENTS),
(ii) Licence together with approved plans and specifications attached thereto.
(NOT REQUIRED FOR THE FIRST GRANT OF A LICENCE),
(iii) Requisite amount of fee for the grant, amendment or renewal of a licenco paid in the manner specified in Rule 72.
F O R M D
(See rules 57 and 58)
LICENCE TO IMPORT GAS CYLINDERS BY SEA
No.
F<* R s
Licence is hereby granted to M/s
to Import by sea at any one time cylinders of the description given below at the port
for consignment to
subject to the provisions of the Indian Explo-
sives Act, 1884 and the rules framed thereunder and to the conditions on the back of this licence.
This licence skill remain in force till the
19
D a t e
LICENSING
AUTHORITY
DESCRIPTION OF THE CYLINDERS
1. Number of cylinders.
2. Specification of cylinders.
3. Manufactured by :
326/6
THE GAZETTE OF INDIA: EXTRAORDINARY
[PART II—SEC. 3(i;]
4. Inspected and tested by :
5. Specifications of the valves fitted to the cylinders.
6. Filled with
(True chemical name of the gas).
7. Filling pressure at 15C, if filled with permanent gas or dissolved acetylene.
8. Filling ratio, if filled with a liquefiablc gas.
9. Date of last hydraulic stretch test.
10. Rotation numbers of cylinders.
Tho licence liable to be cancelled if the cylinders do not conform to the description given in the body of the licence and for contra -
vention of any of the rules and conditions under which this licence is granted and the holder of the licence is also punishable as provided
for under Section 5(3) (a), (b) and (c) of the Explosives Act, 1884.
CONDITIONS Of LICENCE
1. This licence shall become void after the expiry of the period mentioned therein.
2. Filled cylinders on becoming empty shall not be refilled with any gas except after obtaining prior ctmcurrooce of the licens-
ing authority.
3. The licensee shall make prior arrangements for expeditious removal of the filled cylinders from the port of importation to
an n ufhorisfd ^remises.
FORM E
(Sec rule 57 and 58)
Licence No
Fee Rs
Licence is hereby granted to
valid only for the filling of cylinders with compressed gas in the licensed premises described below and shown in the plan No
subject to the provisions of the Indian Explosives Act 1884 (4 of 1884) and the rules made thereunrtcr and to the further conditions of
this licence.
The licence shall remain in force upto 31st day of March 19
The
l^
chief Controller of Explosives
DESCRIPTION AND LOCATION OF THE LICENSED PREMISES
The licensed premises the layout boundaries and other particulars ol which are shown in the attached approved plan No
are situated at
and consist of
for filling of the gas(es) in cylinders as described hcreunder :
Type of gas
(a) Toxic
(b) non-toxic and non-flammable
(c) non-toxic and flammable
fd) dissolved acetylene gas
(e) non-toxic and flammable liciueriable gas other than LPG.
(f) liquefied petroleum jas
and is situated at
(Plot Number (Name of street) (village or town)
(Police station) (District)
SPACE FOR ENDORSEMENT OF RENEWALS
This licence should be renewable without any con- Date of renewal
cession in fee for three years in the absence of
contraventions of Indian Explosives Act, 1884
or Gas Cylinders Rules 1981, framed thereunder
or of the conditions of this licence.
This licence i* liable to be cancelled if the licensed pre-
mises are not found conforminn to the description and condi-
tions attached thereto and contravention of any of The rules
and conditions under which this licence is granted and the
holder of this licence is also punishable with imprisonment
for the term which may extend to two years, or with fine
which may extend to three thousand rupees, or with both.
CONDITIONS
I. The licensed premises shall not be used for any purpose
other than filling compressed gas into cylinders and keeping
Date of expiry
Signature and office stamp of the
licensing authority
thereof for the time being and for the purpose connected
therewith.
2 No cylinder shall be filled with any compressed gas
unless —
(i) such cylinder has been approved in writing by the
Chief Controller for filling : and
Hi) the cylinder }us been examined and tested as re-
quired under the relevant mlej.
326/7
3. Before filling, every cylinder with its valve and other
fittings shall be carefully examined to ensure that it complies
in all respects with the relevant provisions of the rules and
shAll be completely emptied before it is passed for filling.
4. No cylinder shall be filled with any compressed gas in
cxceifi of tile design working pressure and the filling ratio
prescribed under the rule.
5. Where it becomes necessary to change the valve and
other fittings of the cylinder, a check shall he maintained on
the tare weight originally stamped p n
the cylinder and
necessary corrections made for .my variation.
6. No cylinder which is not painted with appropriate colour
as prescribed in the rules shall be filled with any compres-
sed gai.
7. CompressinK and filling apparatus for any gns shall be
wholly distinct from and unconnected with the compressing
and filling apparatus for nny other gns.
R. No cylinder shall be filled w'th any compressed gas
between the hours of sunset and sunrise except in the manner
and under such other condition(s) specially endorsed on the
licence.
9. All electiical equipment such ns motors, switches, star-
ters, etc.. installed in the premises used for compressing and
filling of flammable gnses shall bo of flameproof construc-
tion conforming to TS : 2148.
10. No artificial light capable of igniting flammable vapour
or gas shall at any time be present at 1he premises during
the filling of any compressed gas in cylinder and no person
enftaged in such filling shall smoke.
11. Every person managing or employed on or in connec-
tion with the licensed premises shall abstain from any act
whatsoever which tends to cause fire or explosion and which
is not reasonably necessary and to the best of his ability,
skill prevent any other person from doing such net.
12. The licensee shall provide at the licensed premises a
minimum of tww portable foam type or dry chemical type
lire exlmeuishcis of 9 kg. each which shall be kept ready
at <i convenient location for immediate use in the event cf.
any lire. Such fire extinguishers shall be periodically checked
for their serviceability.
13. All filling operations shall be supervised under thi
diiec. supervision of a competent person.
14 Ihe licenced premises used for compressing and filling
of liquefied petroleum gas shall at all time maintain a clear
safety /one of 10 metres all round from any building, public
place, public ioad or any adjoining property which may be
built upon.
15. The licensed premises shall be constructed of non-
flammnhlc materials and adequately ventilated.
Ifi. Any accident, fire or explosion within the licensed
piemisei which is attended with loss of life or serious injury
to proon or property shall be immediately reported to the
nearest Magistrate or to the Officer-in-Charge of the nearest
Police Station and by Express telegram to the Chief Cont-
roller of Explosives (Telegraphic "address "EXPLOSIVES",
NAGPUR1).
17. Free access to the licensed premises shall be given
at all reasonable time to any of the officers listed in rule 78
and every facility sb.ill be afforded to such officer for as-
certaining that the rules nnd the conditions of this licence
are duly observed.
FORM F
(Sec rules 57 and 58)
Licence No
F e o R s
Licence is hereby granted to
valid only for the possession of cylinders filled with compressed gas in the licensed premises described below and shown in the plan No
subject to the provisions of the Indian Explosives Act, 18S4 (4 of 1RR4) and the rules made thereunder and to
the farther conditions of this licence.
The licence shall remain in force upto 31st day of March 19
Chief Controller of Enolosive*.
Description and location of the licensed premises.
The ' licensed premises, the layout boundaries and other, particulars of which arc shown in the attached approved plan No
are situated at
and consist of
of possession uf the gas col»uiii«u'
in cylinders as described hereunder;
Type of gas
Quantity
(a) toxic
(b) non-toxic and non-flammable
(c) Non-toxic and flammable
(d) dissolved acetylene gas
(e) non-toxic and flammable liqueflable gas other than LPO.
(f) liquefied petroleum gas
and is situated it
(Plot Number) (Name of street) (village or Town) (Police Station)
(District)
SPACE FOR ENDORSEMENT OF RENEWALS
This licence shall be renewable without any con- Date of renewal
Date of expiry
Signature andlrt_mp of the licensine
cession in fee for three years in the absence of
authority
contraventions of Indian Explovives Act 1884, ————.——
• — -
.
_ _ _ _ _
or Gas Cylinders Rules, 1981, framed thereunder ——
———__„___„
—
—
^
_ _ _ _
or of the conditions of this licence.
— - .
— — ^ _ _ _ _ _ _
,
'
~~
326/8
THfc (JA/trlE OF INDIA : EXTRAORDINARY
[PART II-SEC. 3(01
ThU licence is liable lo tie cancelled if the licensed premi-
ses :ire not found conforming to the description and condi-
tions, attached hereto and contravention of any of the rules
and condition!, undei which this licence is gi anted and the
holder of this licence is. also punishable with imprisonment
for the lerm vhich muy e\tend to two years or with fine
which rn..} e\tend to three thousand rupee?, or with both.
CONDITIONS
1. The licensed premises shall not be used for nny purpow
olher than for keeping of compressed gas filled in cylinders.
2. Compressed as cylinders '•hall be stored only in the
storage shed which shall be conducted of suitable non-
flammable materials provided that, when only non-flammable
gas filled in cylinder is stored, the beams, rafters, columns,
windows and doors may be of wood.
3. The storage shed shall be adequately ventilated near
the ground 'e^cl and near or in the roof. In case the
storage shed is used for keeping LP. pus cylinder,
the
ventilators shnll be provided wilh two thicknesses of line
corner or other non-corroding metal wire gauze of mesh
not L-1!. th.ui 11 to the linear centimetre.
4. As fur us possible, different types of gases should not
be stoi«l in the samr shed. Where different types of ms
cylinders are stored in 1he same sh?d, cylinders may be
grouped together depending on the nature of the gns coti-
tnined therein e.g flnmmabie nas cylinders shall be separated
from cylinders containing oxidising qases by an intervening
•:pace of one metre or hv a fire resisting partition wall in
between tnVm and cylinder*; containing toxic Rases shall be
secreaaled from the cylinders containing non-toxic gases by
a suitable partition wall.
5. The follow in? distances shall be kept clear at all times
between any buildinq. public place
public roaii or any
adjoining property which may he built upon nnd the storoyc
fbod used f°r the
storage of
liquefied
petroleum
ins
cylinder —
Quantity of compressed
Minimum distance to be
jas in cylinders
kept dear
Kg-
Metre*
0 — 1 0 0
—
101 —
1000
3
1001 —
4000
__
5
4001 —
800O
7
8001 —
12000
9
12001 — 30000
12
over 30000
15
Provided thiit the distance specified above may be reduced
by the Chief Controller (i) where screen walls are provided
or other special precautions tnken, or (ii) where there ore
special circumstances which in the opinion of the Chief Cont-
roller would justify such reduction.
6. Notwithstanding anything
contained in condition
5
above, cylinders containing liquefied petroleum gas exceed-
ing 100 kg., but not exceeding 300 kg. may be kept in a
storage shed forming part of, or attached to a building,
provided that it is separated therefrom by a substantial parti-
tion and the only means of access to it ii from outside air,
such a storage shed shall not be situated under any .itair-
case, or near other entrances to, or exists from the rest of
the building or other buildings.
7. A shed used for storage of liquefied petroleum ga*
cylinders shall be surrounded by a suitable fence to prevent
unauthorised persons fvom having access to the shed.
8 Thin wall i-vlindiis shall not he slacked in a horizontal
poition, provided that in a^e of liquefied petroleum gas
cylinder*, ths following method of srackinj; may be permit-
ted :--
(ij if storej ^ertifillv, shall nut he sUikcd more thun
3 high ; or
til) if stored
horizontally shall not be stacked raoie
than 5 high in the ease of full cylinders and 7
fiich in the case of empty cylindei ;
(ili) the pile of <he cylinders shall be kept liable by irinjj
chocks at the ends ;
(ivj Jt least 60 centimetic wide gangway, to psimit ncccsi
and manoeuvring of cylinder's, shall be left between
.stacks of single or double rows and between sliitks
and walls.
9 True chemical namefs) of the gnses shall be prominontly
displayed in the storpge shed.
10. The storage shed shall he in the charge of a compe-
tent person.
11. Any accident, fire or explosion within the licensed
premises which is attended with loss of life or serious injury
to person o<~ property shall be immediately reported to the
ne.trc^t Magistrate or to the Officer-in-Oharge of the nearest
Police Station and by Express telegram to the Chief Cont-
roller of Explosives (Telegraphic address—"EXPLOSIVES",
NAGPUR).
12. Any person storing gas cylinders, when called upon bv
a notice in writing, to execute any additions, alterations or
repairs to the gas cylinders storage shed, which in the opinion
of the inspecting authority, are necessary for the safety of
the premises, shall execute the said additions, alterations or
repairs within such peiiod not being thin one month from
the
date of receipt of the notice, a^ may
be specified i:l
the notice.
13. No shed used for storage of flammable gases shall
be opened and no handling of the gt's cylinders shall be
permitted between the hours of sunset and sunrise, except
where appioved clectiic lighting is exclusively used,
14. The sotrage shed end the area surrounding it shall
at all times be kept clean and free from all flammable
materials, waste vegetation and rubbish.
15. (a) No fire, furnace or other source of heat or light
other than flameproof electric light and fittings
shall be allowed in the storage shed and within
the safety zone required to be maintained
under
condition 5.
(b) No person shall smoke in the storage shed or carry
matches, fuses or other appliances for producing
ignition in the premises.
Conspicuous 'No smok-
ing' signs in Hindi, English and the region,il lan-
guage shall be pasted or hung up at prominent
places outside the storage shed.
16. The licensee shall provide at the licensed premises n
minimum of two portable foam tvpe ordinary chemical
type fire extinguishers of 9 kg. each which shall be kept
ready at a convenient location for immediate m e in the
event of any fire.
Such, fire extinguishers shall be periodi-
cally checked for their serviceability.
17. Free access to the licensed premises shall be given at
all reasonable times to any of the officers listed in rule 78
and every facility shall be afforded to such officer for ascer-
taining that the rules and the conditions of this licence are
duly observed.
PRINTED BY THE MANAGER, GOVT. OF INDIA PRESS, KING ROAD, NEW DELHI-110064
AND PUBLISHED BY THE CONTROLLFR OF PUBLICATIONS, DELHI-110054, 1981