TENDER NOTICE
[DIMS/TN-06/2007-08]
No. F4-5513/2006/DIMS.
19th June 2007.
Sealed competitive tenders are invited for the supply
and installation of following items at ESI Hospital, Feroke.
1. Pulse Oxymeter
SPECIFICATIONS
Waveform display :
Back lit LCD/TFT diagnostic
Plethysmographic
in
user
adjustable scale
Measurement
Method
:
Red and infrared light absorption
Range
:
SPO2 - 0 to 100%
Accuracy
:
± 2% from 80 to 100%
Pulse rate
:
20 to 250 b. p.m.
Numeric display
:
Saturation %
Averaging 5s, 6s, 9s and 10s
selectable
Sensor machine
:
Reusable finger adult probes
2 Nos. with each. Reusable finger
paediatric size-2 Nos., Reusable
ear probes paediatric size-2 Nos.
Alarms
:
SPO2 User adjustable High SPO2
40 to 99% and OFF, default : OFF
Low SPO2 40 to 99%, default : 90%
Physical
:
Size
:
Portable
Weight
:
Light Weight
Battery backup
:
Built in battery backup for
3 hours minimum
Warranty
:
2 years
Maintenance
:
Should have annual maintenance
contract for 5 years.
2. Electro Surgical Unit
SPECIFICATIONS
(1)
Should be an automatic micro processor base
Electro Surgical Unit with digital display for all
power settings.
(2)
Should have separate programme for Gastro enteric,
cardiovascular, Trans Urethral, Neuro Surgical and
Laparoscopic Surgeries with required internal
adjustments in the quality of CUT & COAGULATION.
(3)
Should have soft, forced & spray types of
monopotar COAGULATION facility
(4)
Bipolar coagulation should have user configurable
Auto start & stop facility. Also delay interval should
be user selectable
(5)
Should have Annual Maintenance Contract for 5
years
(6)
Should have minimum 4 programmable memories to
store user settings
(7)
Should have the automatic check facility to check
HF & LF leakage current, tissue impedance and
patient plate disconnection
(8)
Should have recall facility to view the latest Alarm
conditions
(9)
Should have minimum 4 steps of Haemostatic
control
(10)
Should have frequency compensation which the
output remains stable when input frequency
fluctuations
(11)
Monopolar Cut should be minimum 300W
coagulation power 120W, Spray coagulation 80W
(12)
Bipolar Cut should be minimum 80W, coagulation
power 80W
(13)
Should have flexible silicon patient plate
(14)
Out put should be controlled from foot switch and
electrode handle independently
(15)
Foot switch should be double peddles for cutting
and coagulation & Explosion Protected
Insurance Medical Services Department
(16)
All accessories should be Autoclavable/sterilizable
(17)
Should have automatic switch-off by built in safety
circuit when electrical connection is broken or
activated on high duration
(18)
Should have audible/visual indication on cutting &
coagulation
(19)
All standard accessories 1 set extra are required
with each unit
a. Colour coded double pedal foot
switch (Waterproof)
:
1 No.
b. Silicon Rubber patient plate
:
1 No.
The number and date of opening of the tender
should be superscribed on the envelope containing the
tender.
Cost of Tender form (including taxes)
Original—Rs. 450
Duplicate—Rs. 225
Tenders received after the prescribed date and time
will not be accepted. The maximum period required for
delivery of the equipment should also be mentioned.
Tender forms can be obtained from the office of the
undersigned on payment of cost by cash/money order
from 25-6-2007. An amount of Rs. 50 (Rupees Fifty
only) is to be paid extra for tender form by post.
Earnest money deposit of 1% of the total cost will have
to be produced in the form of Demand Draft taken in
favour of the Director of Insurance Medical Services
along with the filled tender form.
Tenders will be opened on the prescribed date in
the presence of the tenderer at the appointed date and
time.
The equipment tendered should confirm ISI
specification. The prices quoted should be inclusive of
c.Active handle with cable (reusable)
:
5
Nos.
d. Bipolar forceps (insulated bayonet
shaped-reusable)
:
5
Nos.
e. Four wheel trolley (suitable size)
:
1
No.
(20)
Additional accessories required
Active handle with cable (reusable)
:
5
Nos.
Bipolar forceps (insulated bayonet
shaped-reusable)
:
5
Nos.
Silicon Rubber patient plate
:
1
No.
3. ECG Machine
15.2 cm (6″) LCD Screen, folding 600 Display
Waveforms and Digitals. 120-160 bpm Normal
Area Mark. Automatic Foetal movements
Detection 12 Hours Data storage and reload
ability Built in rechargeable Battery for 2
hours continous work
High sensitive 9 elements 2 MHz Pulse
Doppler Transducer
PC Based software for storage, Reload and
analysis
Ante partum and Intrapartum Monitoring
FHR/ToCO/FM/AFM
IUP/DECG (Optional)
High Resolution and Long Life Built in
Thermal Printer
Built in Network Capability
Twin Monitoring Facility (Available only in
FM 9534)
Should have annual Maintenance Contract for
5 years
The successful tenderer should be made Annual
Repair and Maintenance Contract before the purchase
subject to the terms and conditions of ESI Corporation.
More information and conditions governing the supply
can be obtained from the office of the undersigned on
all working hours.
Last date and time of sale of tender form—6-8-2007,
4 p. m.
Last date and time of receipt of filled tenders —6-8-2007,
5 p. m.
Date and time of opening of the tender—7-8-
2007, 11 a. m.
The undersigned authority reserves the right to
accept or reject any tender without assigning any
reason thereof. All other conditions stipulated in the
Kerala State Store Purchase Manual are applicable to
this tender also.
(Sd.)
Director of Insurance
Thiruvananthapuram.
Medical Services.