KERALA GAZETTE
PUBLISHED BY AUTHORITY
©
Government of Kerala
tIcf k¿°m¿
2011
Reg. No. cPn. \º¿
KL/TV(N)/12/2009-2011
No.
\º¿
Vol. LVI
hmeyw 56
}
}
27th December 2011
2011 Unkw-_¿ 27
6th Pousha 1933
1933 s]ujw 6
THIRUVANANTHAPURAM, TUESDAY
Xncp-h-\-¥-]p-cw, sNmΔ
51
PART III
Stores Purchase
Education Department
Z¿Lmkv ]ckyw
[\-º¿ 1/2011-˛12]
\º¿ F2-˛503/2011.
2011 Unkw-_¿ 8.
kmt¶-XnI hnZym-`ymk hIp-∏nse Kh¨sa‚ v
-sS-Iv\n-°¬ sslkv°qƒ, Fgp-tIm¨, sIm√tذv
sPt^-gvk¨ Itk-c-Iƒ hmßp-∂-Xn\v ap{Z-h®
Z¿LmkpIƒ £Wn®psIm-≈p-∂p.
Z¿Lmkv t^mdØns‚ hne—` 400+hn¬∏\ \nIp-Xn.
\nc-X-{Zhyw—1 %.
Z¿Lmkv t^mdw hn¬]-\-bpsS Ahkm\ XobXnbpw
ka-bhpw—4˛1˛2012, 3 aWn.
]qcn-∏n® ko¬h® Z¿Lmkv kzoI-cn-°p∂ Ah-km\
XobXnbpw ka-bhpw—5˛1-˛2012, 1 aWn.
Z¿Lmkv Xpd-°p∂ XobXnbpw ka-bhpw—5˛1-˛2012,
2 aWn.
Z¿Lmkv kw_-‘n-°p∂ hnh-c-߃ Xmsg-∏-d-bp∂
hnem-k-Øn¬ \n∂pw e`n-°p-∂-Xm-Wv. Z¿Lmkv t^md-߃
Hm^okv {]hrØn Znh-k-ß-fn¬ cmhnse 10 aWn apX¬
D®-bv°p-tijw 3.30 aWn-hsc t\cnt´m X]m¬ am¿§tam
e`n°p-∂-Xm-Wv. X]m¬ Ime-Xm-akw Hc-h-Im-i-ambn
]cn-K-Wn-°p-∂-X-√. X]m¬ sNehv {]tXyIw HSp-t°≠-Xm-Wv.
kq{]-≠ns‚ Imcym-e-bw,
Kh¨sa‚ v sS-Iv\n-°¬ sslkv°qƒ,
(H-∏v)
Fgp-tIm¨.
kq{]-≠v.
TENDER NOTICE
No. A2-018/2011.
7th December 2011.
Sealed tenders are invited in the prescribed forms
from competent and experienced concerns for supplying
equipments of production cum Training Centre of VHSE
MLT Course in Govt. VHSS, Valapad vide reference
C1/16120/2011(2) dated, Thiruvananthapuram , 6-1-2011.
Projected Amount—` 4,50,000.
Earnest Money Deposit (EMD)—1%.
Cost of tender forms—` 900+VAT.
Last date and time of receipt of tender—
13-1-2012, 3 p. m.
Date
and
time
of
opening
of
tender—
13-1-2012, 3.30 p. m.
(In case the above mentioned date turnout to be a
holiday, the next working day would be considered as the
last date of receipt/opening of tender.)
Tender forms and list of equipments with
specifications can be obtained from the school office. For
details Ph—0487-2391638, Mobile—9447826195,
E-Mail: [email protected]
Requirements list with specification to GVHSS, Valapad
LIST OF EQUIPMENTS
Sl.
Items required
Specifications
Quantity
No.
(1)
(2)
(3)
(4)
1
Semi-Auto
1. Dual Mode:Both
1 No.
Chemistry
aspiration and
Analyzer
cuvette mode
2. Should be microprocessor
controlled general
purpose bichromatic
photometer system
with at least six filters
ranging from 340 to
630 nm.
3. Light source:
Tungsten/Halogen or
higher grade.
4. Should have flow cell
measuring device.
5. Should have in-built
printer.
6. Should be supplied with
one variable volume
(10-100ul) and one
fixed volume 500ul
pipettes.
7. Should be supplied
with 600V V-guard UPS
2
Automatic
Fixed volume 500ul
1 No.
Micro Pipette
3
Automatic
Variable volume 10-100ul 1 No.
Micro Pipette
4
Flame Photometer
Should provide Na/K
1 No.
standard
5
Binocular Electric 1. Should be by the
1 No.
Microscope
manufacturer Labomed,
Model Vision 2000.
2. Should be equipped
with built-in LED light
source with white light.
(1)
(2)
(3)
(4)
6
Monocular
1. Should be by the
1 No.
Electric
manufacturer Labomed
Microscope
Model CxL
2. Should be equipped
with LED light source.
7
Centrifuge
6×15 ml swing out
1 No.
head Min 3400rpm.
8
Digital
1. Should be with digital 1 No.
Centrifuge
speed regulator with
RPM & digital timer
(0-99 Minutes) under
feather touch system.
2. Should be provided
with interchangeable
rotor head with swing
out head 4200RPM
16×15ml.
9
Bacteriological
1. Should be operated
1 No.
incubator
on 230V, 50Hz single
phase AC supply and
having temperature
ranging from ambient
to 60C.
2. Should be double
walled with stainless
steel inner chamber
having a minimum of
two inner stainless steel
shelves with holes and
powder coated outer
surface.
3. Should have a minimum
chamber size of (L×B×H)
of 300×300×300mm.
4. Should be provided
with three sided
heating elements.
5. Should have synthetic
rubber gasket at the
door.
10
Hot air oven
1. Should be operated
1 No.
on 230V, 50Hz single
phase AC supply and
having temperature
ranging from 50C to
200C.
(1)
(2)
(3)
(4)
2. Should be double
walled with stainless
steel SS304 inner
chamber having a
minimum of two
inner stainless steel
shelves with holes
and powder coated
outer surface.
3. Should have a minimum
chamber size of ((L×B×H)
of 300×300×300mm.
4. Should be provided
with three sided
heating elements.
5. Should be provided
with air ventilations
11
Colorimeter
1. Should have 8 No. of
1 No.
filters wavelength from
400nm to 700nm
2. Should have a three
digit display calibrated
directly in OD
3. Should provide standard
accessories.
12
Autoclave
1. Should be double
1 No.
Vertical
walled construction
with inner SS 304
2. Should have a
minimum volume of
22ltrs.
13
Syringe &
Should be made of
1 No.
Needle Destroyer
MS sheet
14
Hot Plate
1. Should be constructed
1 No.
(Round)
out of MS sheet
2. Should have a
temperature range of
250C-300C
3. Should have 8" diameter
minimum and provided
with energy regulator
15
Sphygmo-
Should be provided
1 No.
manometer
with pressure cuff.
(B.P. apparatus)-
Digital
(1)
(2)
(3)
(4)
16
Common balance
Should be from ISI
1 No.
marked reliable firm
17
Weight box
Should be calibrated
1 Pkt.
18
Stop watch
ISI marked
1 No.
19
Refrigerator
1. Should be double door
1 No.
frost Free
2. Minimum capacity
should be 220L
3. Should be at least 4
star rated.
20
Water Bath
1. Should be double
1 No.
(Thermostatic)
walled with inner SS
2. Should be fitted with
thermostat
3. Working temperature
should be from ambient
+5C to 80C
4. Should have minimum
inner dimensions of
300×250×175mm
21
V. D. R. L.
1. Should be made of
1 No.
Rotator
MS body
2. Should have a
minimum plat form
size of 300×300mm
3. Should be equipped
with 0-15 min timer
upto 180RPM min.
22
Distillation
1. Should be wall
1 No.
Apparatus
mounting
(Water Still)
2. Should be made of
complete SS and
fitted with ISI marked
heaters.
3. Should be provided
with wall mounting
clamp.
23
Electronic
1. Maximum capacity
1 No.
Weighing
200gm.
Machine
2. Sensitivity-10mg.
3. Set of calibrated
analytical weight
should be provided.
(1)
(2)
(3)
(4)
24
Bunsen
ISI Marked
1 No.
burner
25
Westergen's
Should carry
2 Nos.
stand
minimum 6
Westergren's
pipettes
26
Test tube
Should be made
5 ,,
rack
up of pp
27
Test tube
Should have
5 ,,
holder
wooden grip
LIST OF REAGENT KIT & GLASSWARE
Sl.
Items Required
Specifications
Quantity
No.
(1)
(2)
(3)
(4)
1
Widal kit
4×50 ml (30 test)
1 Pkt.
2
RPR kit
50 test
1 ,,
3
Cholesterol kit
100 ml
1 ,,
4
TG kit
100 ml
1 ,,
5
HDL kit
50 ml (peg)
1 ,,
6
LDL-direct
Direct-100 ml
1 ,,
7
HDL-direct
Direct-100 ml
1 ,,
8
Disposable Syringe
2ml, 100/pkt,
1 ,,
and Needle
ISI marked, sterile
9
Medi. Spirit
500 ml
1 Bottle
10
Tissue paper
1 roll
1 Roll
11
Lancet
Sterile, Disposable
1 Pkt.
100/pkt.
12
Pasteur pipette
Glass, long narrow
1 ,,
tipped
13
Plaster
Roll
25 ,,
14
Test tube (medium)
Borosilicate
50 Nos.
15
Test tube (small)
Borosilicate
50
,,
16
Leishmans stain
500 ml
1 Bottle
17
Cedar wood oil
25 ml
1
,,
18
Urea kit
75 ml
1 Pkt.
19
Creatinine kit
2×75 ml
1 ,,
20
ALP kit
10×1 ml
1 ,,
21
Na/K kit
15 TEST each
1 ,,
22
Petridishes
P. P.
1 ,,
(1)
(2)
(3)
(4)
23
Glass slide
100/Packet
10 Pkt.
24
Drabkins reagant
300 ml
1
,,
25
RBC diluting fluid125 ml
1 Bottle
26
WBC diluting fluid
125 ml
1
,,
27
Widal Tube
10×75 mm
50 Nos.
10×75 mm
28
Concentrated carbol 500 ml
1 Bottle
fuchsin
29
Spirit lamp
S. S.
3 Nos.
30
Conc. HCI
500 ml
1 Bottle
31
Methelene blue
25gm
1
,,
32
Grams lodine
125 ml
1
,,
33
Crystal violet
125 ml
1
,,
34
Acetone L. R.
500 ml
1
,,
35
Dil. Carbol fuchsion 125 ml
1
,,
36
Sterile specimen
50 ml capacity
25 Nos.
containers
37
Absorbent Cotton
Packet
1 Pkt.
38
Non Absorbent
Packet
1 ,,
Cotton
39
Haemoglobinometer
For Hb estimation
1
,,
(Sahli's)
by Sahli's
40
Haemocytometer
Should be Bright
1
,,
line
41
Capillary tube
Plane, thin walled
1
,,
42
Filter paper
Sheet
5 Sheet
43
PH paper
Packet
1 Pkt.
44
Tourniquet
Rubber
2 Nos.
45
EDTA anticoagulant 100 gm
1 Bottle
46
Sodium citrate 3.8% 500 ml
1
,,
47
Sulphur powder
500 gm
1
,,
48
Occult blood kit
Packet
1 Pkt.
49
Fouchets reagant
125 ml
1 Bottle
50
Barium Chloride
500 ml
1
,,
51
Ammonium sulphate 500 gm
1
,,
52
Sodium Chloride
500 gm
1
,,
53
Glacial acetic acid500 ml
1
,,
(1)
(2)
(3)
(4)
54
Benedicts reagant
1000 ml
1 Bottle
55
Diastix
Glucose
1 Pkt.
56
Blood Sugar kit
GOD-POD method
1
,,
(GOD-POD)
57
Antisera (blood
Anti A, Anti B,
1
,,
grouping)
Anti D
58
Stationery Items
A4 Printer paper
1 Packet
Pen
3 Nos.
Pencil
3 ,,
Scale
2
,,
Writing Pad
5
,,
Ink Pad
1
No.
Stapler & Pin
2
Nos.
Envelopes
50 ,,
Pen stand
1
No.
Report Tray
5
Nos.
Waste Basket
3
,,
LIST OF INFRASTRUCTURE FACILITY
Sl.
Items Required
Specifications
No.
1
Lab Structuring
Should include Reception table,
Chair, 12 Nos. of patient waiting
chairs, phlebotomy chair etc.
2
Lab Electrification
Should include basic electrifi-
and plumbing
cation and plumbing accessories.
Govt. Vocational Higher
(Sd.)
Secondary School, Valapad.
Principal.