CUTTACK DEVELOPMENT AUTHORITY ( PLANNIG AND BUILDING
STANDARD) REGULATION, 2024
NOTIFICATION
The 30th January 2025
No. 778/ 27.01.2025ʊWhere as the Draft Cuttack Development Authority
(Planning And Building Standards) Regulations for Old Areas of Cuttack, 2024 has
been prepared under the Section 124 of Odisha Development Authority Act, 1982
with approval of Housing & Urban Development Department, Government of
Odisha vide Letter No. HUD-TP-CASEOP-0017-2023-24895, dt. 26/11/2024.
And whereas, under section 125 of Odisha Development Authority Act,
1982 all persons/ authorities likely to be affected thereby, may send their
objections/suggestions addressed to the Secretary, Cuttack Development Authority
before the expiry of 15 days from the date of publication of the above notification in
Odisha Gazette.
And whereas, any objection/suggestion which may be received by Cuttack
Development Authority in respect of the above draft regulations before the expiry of
the period so specified above will be considered by Cuttack Development Authority.
Vice Chairman
ANAM CHARAN PATRA
CDA, Cuttack
The Odisha
G a z e t t e
EXTRAORDINARY
PUBLISHED BY AUTHORITY
No. 684 CUTTACK, FRIDAY, MARCH 21, 2025/FALGUNA 30, 1946
DRAFT CUTTACK DEVELOPMENT AUTHORITY (PLANNING AND BUILDING
STANDARDS) REGULATIONS FOR OLD AREAS- 2024
CHAPTER-I.
DEFINITIONS
1. Short title, extent and commencement
(1)
These regulations may be called Cuttack Development Authority (Planning and Building
Standards) Regulations for Old Areas - 2024.
(2)
These regulations are to be read in conjunction with Odisha Development Authorities (Planning
and Building Standards) Rules- 2020 and Odisha Development Authorities (Common Application
Form) Rules- 2016.
(3)
They shall extend to the Old Areas delineated as under Annexure I of these regulations.
(4)
They shall come into force on the date of their publication in the Odisha Gazette.
2. Definition
(1)
In these regulations, unless the context otherwise requires,
(i)
Old Area
delineated in Annexure I of these regulations;
(ii)
any parcel of land which is connected through a
public/private means of access of width of 1.50 - 3.00 m meters
(iii)
Width P
means a plot having maximum 7.50 meter in width on abutting road
irrespective of the depth.
(iv)
refers to a plot with private access road ranging from 1.50 m-
3.00 m formed due to sub-division particularly among family members (Ismail access)
CHAPTER
II.
ADMINISTRATION
3. Applicability of Regulation
Subject to the provisions of the Act and Rules made there under, these Regulations shall apply to.
(i)
all development, redevelopment, erection and or re-erection of a building as well as to the design,
construction of, or reconstruction and additions and alterations to a building.
(ii)
all parts of the building whether removed or not, and in case of removal of whole or any part of the
building;
(iii)
the remaining part of the building after demolition and work involved in demolition in case of
demolition of whole or any part of a building;
(iv)
all parts of the building affected by the change in occupancy of a building; and
(v)
use of any land or building where sub-division of land is undertaken or use of land or building is
changed.
2
4. Applicability to existing buildings
(1)
The construction of any building in respect of which permission has been issued before coming
into force of these regulations shall, so far as it is not inconsistent with the provision of these
regulations regarding provision of public utility services and construction in special heritage zone,
continue to be validly made and the said permission shall be deemed to have been issued under
the corresponding provisions of these regulations.
(2)
Where any building has been constructed without an approved plan, the provisions of these
regulations shall be insisted upon.
(3)
Wherein the building has been constructed with deviation of an approved plan, the provisions of
these regulations shall be insisted upon except for the provisions related to compounding where
benefit of earlier regulations under which approval given would have been extended.
(4)
For the purpose of compounding the deviation under Clause-1 the Authority may formulate a
regularization scheme with the approval of the Government specifying a maximum time period of
one year after publishing of the same in the Orissa Gazette, local newspaper, electronic media
and website of the Government and Authority.
5. Permission
(1)
No permission shall be required for the works specified in clause-12.4.1, Part-2 of The National
Building Code of India, 2016 section 15, of the Orissa Development Authorities Act, 1982 and
Rule 10 of ODA (P&BS) Rules, 2020.
(2)
No permission shall be required for the following alterations, which do not otherwise violate any
provisions regarding general building requirements, structural stability, fire and health safety
requirements of these rules or National Building Code of India, 2016 clause 4, Part-3.
(i)
Raising of existing plinth of building not in consistence of regulation at own risk and cost of
applicant such that it shall be so located with respect to average road level from site so that
the adequate drainage of the site is assured. The height of the plinth shall not be less than
45 cm suitably to avoid waterlogging and drainage issues in the plot as well as adjoining
plot and shall adhere to setbacks as per regulations enforced at time of building approval
(ii)
Installation of medical oxygen plants in hospital premises
(iii)
Opening and closing of a window or door or ventilator;
(iv)
Providing intercommunication doors;
(v)
Providing partitions;
(vi)
Providing false ceiling;
(vii)
Gardening;
(viii) Whitewashing;
(ix)
Painting;
(x)
Re-tiling and re-roofing;
(xi)
Plastering and patchwork;
(xii)
Re-flooring and
3
(xiii) Construction of sunshades on
own land.
(3)
All clarifications with respect to deficiency in the plan, documents shall be sought for from the
applicant within 30 days after receipt of application.
(4)
Once the plan has been scrutinized and objections have been pointed out and intimated to the
applicant, the applicant shall modify the plan to comply with the objections raised and re-submit it
for further scrutiny and the Authority shall pass orders as per rules and regulations.
(5)
The Authority shall communicate either approval in Form-II or refusal in Form-III appended to the
Odisha Development Authorities (Common Application Form) Rules, 2016.
(6)
If the Authority does not communicate its decision either granting or refusing permission to the
applicant within 60 days from the date of receipt of the application by the Authority, the applicant
shall draw the attention of the Vice-Chairman of the Authority with regard to his application, in
Form-I and the Planning-Member shall within fifteen days from the date of receipt of notice in
Form-I appended to the Odisha Development Authorities (Common Application Form) Rules,
2016,place the details of the case before the Vice-Chairman.
(7)
If, within a further period of one month from the date of receipt of the application drawing such
attention as mentioned in sub-regulation (6), the Authority does not communicate its decision,
such permission shall be deemed to have been granted to the applicant on the following the date
of expiry of the three months period.
(8)
Construction proposed in all existing buildings which have been divided into parts by partition or
sale or otherwise may be permitted (without insisting on front, rear or side setbacks) subject to
fulfilment of following provisions, namely; -
(i)
Coverage provided for the upper floor shall not exceed 75% of the plinth area of existing
floor for organizing an open terrace to facilitate light and ventilation to the habitable rooms;
(ii)
Separate arrangement shall be made for drainage of the storm water;
(iii)
Ventilators may be permitted above lintel height on production of no objection certificate
from the owners of the adjacent plot to which the ventilators abuts, but no window
overlooking others property may be permitted without obtaining his written consent in the
shape of an affidavit.
6. Restriction of permission
This regulation shall not be applicable in the following cases, namely
(1)
Where construction has been undertaken on the Government land or land belonging to local body
or land not owned by the person undertaking such development;
(2)
Where constructions have been undertaken over public or private road or on the alignment of any
of the natural drainage channel, Municipal drain, sewerage line, electrical line, water supply
network or any public utility services proposed in the Development Plan or otherwise;
(3)
Where construction has been undertaken in violation of the Ancient Monuments, and
Archeological Sites and Remains (Amendment and Validation) Act, 2010;
Provided that such constructions can be given permission if no objection certificate from the
concerned authority is produced.
(4)
Where construction has been undertaken in violation to the height restrictions notified by the
Airport Authority of India:
4
Provided that such constructions can be permitted if no objection certificate from the concerned
authority is produced
(5)
Where construction has been undertaken in violation of the zoning regulations governing
Environmentally sensitive zone, open space /recreational use zone or any other special land use
zone as identified in the Comprehensive Development Plan
(6)
Where construction has been undertaken in violation of any norms of Eco-sensitive zone notified
by Forest and Environment Department;
Provided that such constructions can be permitted if a No Objection Certificate from the concerned
authority is produced;
(7)
Where construction or usage of land or building has been undertaken in violation of conditions of
lease in case of leasehold land leased by Revenue and Disaster Management Department or any
other public agencies.
CHAPTER
III
LAND USE CLASSIFICATION AND PERMISSIBLE USES
7. Zoning
(1)
In the Development Plan various Land Use Zones (LUZ) are indicated with their specific
boundaries and these land use zones shall be regulated in accordance with the provisions of Table
1.
(2)
Except as otherwise provided, no structure or land hereinafter shall be used and no structure shall
be erected, re-erected or altered unless its use is in conformity with these zoning regulations.
(3)
In cases where a layout plan of land has been approved and various plots of land under such
layout have been assigned specific land uses, then the same shall be adhered to unless any such
use falls under prohibited category specified in column (e) of Table 1 of that LUZ.
(4)
All places of worship, temples, churches, mosques, burial and cremation ground as existing on
the date of notification of this regulation shall be exempted from being treated as non-conforming
uses. Provided that continuance of such uses are not detrimental to the locality as decided by the
Authority from time to time for consideration of such cases.
8. Different use of land
(1)
Permission for different uses shall be accorded for principle uses earmarked in the different zones
as described in column (c) of Table-1.
(2)
Permission for different uses described in column (d) of the Table 1 shall be accorded on special
consideration by the DP&BP Committee and reasons for such considerations shall be recorded in
writing and it is further provided that Authority may prescribe terms and conditions including levy
of fees and charges for guidance of the committee for consideration of such cases.
(3)
The activities specified in column (e) of Table-1 shall not be permitted in the areas reserved for
particular uses.
(4)
The purposes which are not specified in column (c), column (d) and column (e) of the Table-1
shall be interpreted by the DP&BP committee on basis of such analogous entries in these
columns.
(5)
(1) Individual Residential Development may be permitted on recommendations of DP&BP
5
Committee in the open space/ recreational use zone if the following conditions are satisfied along
with other conditions of these regulations, namely:-
(i)
the land is a stitiban land and is not a leasehold land;
(ii) the coverage is not more than 50% and FAR of 1.0
(iii) the height is not more than 7.0 meters excluding headroom and at least 30% of the land is
used for plantation.
(2) Subject to the provision contained in Regulation (5) construction of non-high rise residential
apartments/housing project may be permitted in open space /recreational use zone if the following
conditions are satisfied along with other conditions of the Regulations namely.
(i)
The minimum size of the plot shall be 1 hectare or above.
(ii)
The minimum width of the approach road shall be 9.0 meter.
(iii)
The maximum coverage shall not exceed 25% of the plot area.
(6)
Mixed use of the building may be permitted in a particular zone on plot:
Provided that the principal use of the building shall cover not less than 2/3rd of the total floor area
and other permitted uses shall not exceed 1/3rd of the total area;
Provided further that, for FAR over and above Base FAR, the applicant shall have the option to
change the above proportion subject to minimum 1/3rd of built-up area towards principal use.
Provided further that purpose of this regulation principal use is any of the uses described in column
(c) of Table 1 and the permitted use is any of the uses described in column (d) of Table 1, if so,
permitted by the DP & BP Committee.
(7)
Subject to the provisions contained in Rule 20 of the Odisha Development Authorities (Planning
and Building Standards)
Rules, 2020, the following provisions shall be applicable for all
constructions in Special Heritage Zone earmarked in the Comprehensive Development Plan,
namely: -
a) The maximum height of the building shall not exceed 12.00 meters; and
b) All proposals for development over an area of more than 500 sqm. or 10.00 meter height or
both shall only be considered on recommendation of the DP & BP Committee with
representation from Archaeological Survey of India and the Odisha State Archaeology
Department.
(8)
(i) For construction of Building in Environmentally Sensitive Zone, the following provisions shall be
applicable, namely.
a) The minimum size of the plot shall be 2000.00 square meter.
b) The minimum width of the approach road hall be 9.00 meter.
c)
The maximum coverage shall not exceed 40% of the area.
d)
The proposal for development shall only be considered on recommendation of DP & BP
Committee with representatives from (1) Water Resource Department (2) Odisha State
Pollution Control Board and (3) Public Health Engineering Department in the above
committee.
6
7
(ii) In case of sub divisional Layouts shall be permitted in Environmentally Sensitive Zone,(ESZ) if
the following conditions are satisfied along with other conditions of these regulations, namely:
a) (a) The minimum size of the plot shall be more than 2.00 Ha;.
b) the minimum width of approach road as required under ODA (P&BS ) Rules, 2020 shall not
be less than 12.00 meter;
c) No relaxation on required width of approach road specified for sub divisional layouts shall be
permitted;
d) The proposal for development shall only be considered on recommendation of DP and BP
Committee with representatives from Water Resource Department, State Pollution Control
Board and Public Health Engineering Department.
e) Notwithstanding anything to the contrary to the provisions specified in this regulation all other
conditions applicable for Sub divisional layout under ODA (P&BS) Rules, 2020 shall be
applicable.
(9)
Residential Density: The density in a residential area shall be guided as per the infrastructure
available. The spot density for a particular plot (proposed for multi-family dwelling shall in no case
exceed 400 persons per acre.
(10) CNG/ Petrol Filling Station shall be permitted complying to the standards of Petroleum Act
irrespective of land uses in Development Plan, except water bodies/forest use zone on
recommendation of the DP&BP Committee if the following conditions are satisfied:
(i) The minimum width of approach road shall be 9.00 meter.
(ii) It shall fulfill the Planning norms as per Rule 67 of Odisha Development Authorities (Planning
and Building Standards)
Rules, 2020.
(iii) Submission of all clearances/ NOCs for installation of such petrol pump.
(11) In this Regulation, the following provisions shall be followed:-
Table 1- Land Uses Permitted/ Prohibited in different Land Use Zones
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
1.
Residential
Use Zone
1.
All types of Residential
activities
2.
Hostel, Boarding and
lodging houses
3.
Night shelters, guest
houses,
Dharmashalas,
4.
Services
for
households
(salons,
parlors,
bakeries,
sweet
shops,
dry
cleaning,
Internet
kiosk, etc.)
5. Retail shopping
6.
Neighborhood
level
social,
cultural
and
recreational
facilities
with adequate parking
1.
Shopping
Mall
&
Multiplex
2.
Places
of
entertainment,
cinema halls
3.
Restaurants
and
hotels
4.
Tourism
related
services
5.
Markets
for
retail
goods
6.
Petrol Filling Stations
7.
Motor
vehicle
repairing workshop/
garages,
8.
Colleges
and
research institutions
9.
IT,
IT
enabled
1.
Use/activity
not
compatible
to
the
land use
2.
Heavy,
large
and
extensive industries,
noxious,
obnoxious
and
hazardous
industries
3.
Warehousing, storage
godowns
of
perishables,
hazardous,
inflammable
goods,
wholesale mandis ,
junk yards
4.
Workshops for buses
5.
Slaughterhouses
6.
Hospitals
treating
8
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
provisions
7.
Community
centers,
clubs, Auditoriums
8.
Marriage
and
community halls
9. Educational buildings
(nursery,
primary
school, high school)
10. Health clinics,
yoga
centers, dispensaries
11. Library
and
gymnasiums
12. Exhibition
and
art
galleries
13. Places of worship
14. Municipal, state and
central
Government
offices
15. Outdoor and indoor
games
16. Public
utilities
and
building except service
and
storage
yards,
electrical
distribution
depots
and
water
pumping stations
17. Nursery
and
green
houses
18. Police
posts/station
and post offices.
19. Banks
and
professional offices not
exceeding one floor.
20. Nursing homes and
health
centers
(20
beds)
21. Household industries if
the area for such use
does not exceed one
floor and there shall be
no public display of the
goods.
22. Bus stops, taxi stands.
3 wheeler/auto stands,
rickshaw stands
23. Parks and tot-lots
services
10. Stadiums,
shooting
range
11. Storage
of
LPG
cylinders
12. International
conference center
13. District
battalion
offices
14. Burial grounds
15. Forensic
science
laboratory
16. Sewage
treatment
plants
17. Solid
Waste
Treatment
Plant/Composting
Sites
18. Water
treatment
plants
19. Printing
presses
employing not more
than 10 persons
20. Godowns/ware-
housing of non
-
perishables
21. Consulates
22. Hospital
23. Public Bus depots
contagious diseases
7.
Sewage
disposal
sites
8.
Solid waste dumping
grounds
9.
Zoological
garden,
botanical garden, bird
sanctuary
2.
Retail
Commercial
Use Zone
1.
Retail.
business,
mercantile
2. Commercial center
3.
Residential uses
4.
Service garages
5.
Banks and financial
services
and
stock
exchanges
6.
Printing
presses
employing not more
1.
Wholesale
storage
yards
2. Weigh bridge
3.
Slaughterhouses
4.
Sewage
treatment
plants
5.
Solid
waste
treatment Plant
6.
Hospital with more
than 20 beds
1. Polluting industries
2.
Heavy,
extensive,
noxious,
obnoxious,
hazardous
and
extractive
industrial
units
3.
Hospitals/research
laboratories
treating
contiguous diseases
4.
Poultry farms, dairy
9
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
than 10 persons
7.
Perishable
goods
markets
8. 20 bedded hospitals
9.
Business
and
Professional Offices
10. Composting Sites
11. Private
institutional
offices,
and
semi-
governmental offices
12. Shops and shopping
malls
13. Commercial Services
14. Colleges, Polytechnics
and higher technical
institutes
15. Restaurants and hotels
16. Sports complex and
stadiums
17. Transit homes
18. Hostels,
boarding
houses,
social
and
welfare
institutions,
guest houses
19. Convenience
and
neighborhood
shopping centers, local
shopping
centers,
weekly
and
formal
markets, bakeries and
confectionaries
20. Cinema halls, theaters,
banquet
halls,
auditoriums
21. Places
of
entertainment
recreational uses and
museums
22. Convention centers
23. Marriage
and
community halls, night
shelters
24. Public
utilities,
telephone exchanges
25. Clinics
and
nursing
homes, Hospitals
26. Religious places
27. Petrol Pumps
28. Police
posts/station
and post offices
29. Residential projects
30. IT
and
lT
enabled
services
31. Commercial institutes,
research and training
institutes
7.
Agriculture
uses,
storage of perishable
and
inflammable
commodities
8.
District
battalion
offices
9.
Sports
training
centers
farms
5.
Sewages
disposal
sites,
solid
waste
dumping grounds
6. Quarrying of gravel,
sand, clay and stone
7.
Zoological
gardens,
botanical
gardens,
and bird sanctuary
8.
Use/activity
not
compatible to the land
use
10
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
32. Parking
lots,
taxi
stands,
3-wheeler/
auto stands, rickshaw
stands
33. Picnic Hut
34. Forensic
science
laboratory
3.
Wholesale
Commercial
Use Zone
1.
Wholesale and retail
business
2.
Wholesale and storage
buildings
3.
Service
centers,
garages, workshops
4.
Banks and financial
services
5.
Government and Semi
Govt offices
6.
Associated residential
uses,
residential,
apartment
7.
Commercial
and
business offices and
workplaces
8.
Petrol
pumps
and
service
stations
on
roads of 30 meter or
more ROW
9. Godowns,
covered
storage
and
warehousing
10. Weigh bridges
11. Bus stops, taxi stands,
3-wheeled/auto
stands,
rickshaw
stands
12. Parking spaces
13. Restaurants
14. Water treatment Plants
15. Public utilities
16. Police
station/posts,
post office
1.
Truck terminal, bus
depots and parking,
Freight terminal
2. Warehousing,
storage, godowns of
perishable,
inflammable goods,
coal, wood, timber
yards
3. Non-polluting,
non-
obnoxious
light
industries
4. Junk yards
5.
Gas installation and
gas works
6.
Railway yards and
stations, road freight
stations
1.
Use/
activity
not
compatible to the land
use
2. Polluting industries
3.
Large scale storage of
hazardous and other
inflammable materials
except
in
areas,
specifically
earmarked
for
the
purpose
4.
Industrial Use
Zone
1. All
kind
of
non-
polluting industries
2. General business
3.
Industrial
Research
institute
4. IT and ITES
5.
SEZ
notified
by
Government of India
6. Sport
stadiums/playgrounds
7.
Cold storage and ice
factory
8.
Loading,
unloading
spaces
9.
Warehousing, storage
1.
Heavy,
extensive
and other obnoxious
hazardous industries
subject
to
the
approval
of
the
Odisha
Pollution
Control Board
2.
Recreational sports
or centres
3.
Technical
Educational
Institutions, Schools
and colleges
4.
Junkyards
5.
Sewage
disposal
1. Use/activity
not
compatible to the land
use
2.
Irrigated and sewage
farms
11
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
and depots of non-
perishable and non-
inflammable
commodities
10. Gas godowns
11. Govt.
semi-Govt.
private
business,
offices
12. Wholesale
business
establishments
13. Banks,
financial
institutions and other
commercial offices
14. Petrol
filling
station
with
garages
and
service stations
15. Bus terminals and bus
depots and workshops
16. Parking, taxi stands, 3-
wheeler/auto
stands,
rickshaw stands
17. Residential
buildings
for essential staff and
for watch and ward
18. Public utilities
19. Agro-based industries,
dairy and farming
20. Workshops garages
21. Industrial Housing
22. Museum,
Hospitals
and medical centers,
social buildings
works, electric power
plants,
service
stations
6. Religious buildings
7.
Major oil depot and
LPG refilling plants
8.
Residential building
in
non-polluting
industrial
9. Affordable housing
10. Gas installations and
gas works
11. Helipads
12. Hotels, motels, guest
houses
5.
Public
and
Semi-public
Use Zone
1.
Government
offices,
central, state, local and
semi-government,
public
undertaking
offices
2. Residential
3.
Commercial
and
IT
services
4. Defense quarters
5. Universities
and
specialized
educational
institutions,
colleges,
schools, research and
development centers
6.
Social
and
welfare
centers
7.
Libraries
8.
Hostels,
transit
accommodation
9.
Nursery
and
kindergarten,
welfare
center
10. Retail
commercial
1.
Workshops
for
servicing and repairs
2.
Processing and sale
of farm products
3. Bus
and
Truck
terminals, helipads
1.
Use/activity
not
compatible to the land
use
2.
Heavy, extensive and
other
obnoxious,
hazardous industries
3. Slaughterhouses
4. Junkyard
5. Wholesale mandies
6.
Dairy
and
poultry
farms farmhouses
12
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
including
entertainment
and
recreational
complexes
11. Open
air
theatre,
playground
12. Residential club, guest
house and hotels
13. Parking
areas,
taxi
stands, 3-wheeler/auto
stands,
rickshaw
stands
14. Hospitals,
health
centres, dispensaries
and clinics
15. Social
and
cultural
institutes
16. Religious buildings
17. Conference hall
18. Community
halls,
Kalyan
mandap,
dharamashala
19. Museums,
art
galleries,
exhibition
halls, auditorium
20. Police Stations, Police
lines, jails
21. Local state and Central
Govt. offices uses for
defense purpose
22. Educational
and
research institutions
23. Social and cultural and
religious institutions
24. Local
municipal
facilities
25. Uses
incidental
to
Govt. offices and for
their use
26. Monuments
6.
Utility
and
Service Use
Zone
1. Post offices, Telegraph
offices, public-utilities
and buildings
2. Service industry
3.
Water
Treatment
Plant,
Sewage
Treatment Plant, Solid
waste Treatment Plant
solid waste dumping
grounds
4.
Radio transmitter and
wireless
stations,
telecommunication
centers,
telephone
exchange
5. Information/payment
1.
Warehouse/storage
godowns
2. Health
centre
for
public and staff or
any
other
use
incidental to public
utilities and services
3. Residential use
4.
Truck
terminals,
helipads
5.
Commercial
use
centre
6.
Institutional building
1.
Use/activity
not
compatible to the land
use
2.
Heavy, extensive and
other
obnoxious,
hazardous industries
13
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
kiosk
6.
Water
supply
installations
7.
Sewage
disposal
works
8. Service stations
9.
Cremation
grounds
and cemeteries/burial
ground
10. Power plants/electrical
substation
11. Radio and television
station
12. Fire stations
7.
Recreational
Use Zone
1.
Specialized
parks/
maidans
for
multipurpose use
2.
Building and structure
ancillary
to
use
permitted
in
open
spaces and parks such
as stands for vehicles
on hire, taxis, and
scooter
3.
Commercial
use
of
transit
nature
like
cinemas, circus and
other shows
4.
Regional parks, district
parks,
playgrounds,
5.
Open Parking areas,
Caravan parks
6. Stadiums
7.
Shooting range, sports
training center
8. Swimming pools
9.
Botanical
and
Zoological
Garden,
bird sanctuary
10. Green belts
11. Animal racing or riding
stables
12. Open
air
cinemas/
theatre
13. Open
air
theater,
theme
parks,
amphitheaters
14. Residential
1.
Public
assembly
halls
2.
Restaurants, picnic
huts, holiday resorts
3.
Entertainment
and
recreational
complexes
4.
Community
hall,
library
5.
Residential
club,
guest house
6. Camping sites
7.
Yoga and meditation
centers
8.
Commercial
uses
center
9.
Special
education
areas
10. Institutional
11. Bus
and
railway
passenger terminals
12. Public utilities and
facilities
such
as
police post, fire post,
post and telegraph
office, health center
for players and staff
1.
Use/activity
not
compatible to the land
use
8.
Transportation
Use Zone
1. All types of roads
2.
Way side slopes and
restaurants
3.
Railway stations and
yards
4.
Airport
5.
Bus stops and Bus and
1.
Authorized/ Planned
Vending areas
2.
Incidental/ ancillary
residential use
3.
Emergency
health
care center
4.
Tourism
related
1.
Use/activity
not
compatible to the land
use
14
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
Truck Terminals
6. Taxi
stands,
auto
stands,
rickshaw
stands, Ferry ghats
7. Institutional Use
8. Parking areas
9. Multi-level car Parking
10. Filling
stations,
transport
offices,
booking offices
11. Night shelter, boarding
houses,
12. Banks, Restaurants
13. Commercial use
14. Workshops
and
garages
15. Automobile spares and
services, Godowns
16. Warehouses, Storage
depots
17. Loading and unloading
platforms(with/without
cold storage. facility,
weigh bridges)
18. Utility
networks
(drainage,
sewage,
power,
telecommunications)
project
5.
All
ancillary
(complimentary)
uses
for
above
categories
(subject
to decision of the
Authority)
9.
Agricultural
and
Forest
Use Zone
1. Agriculture
and
Horticulture
2.
Parks
and
other
recreational uses
3.
Dairy
and
poultry
farming, milk chilling
4.
Storage,
processing
and
sale
of
farm
produce
5.
Agro Serving, agro
processing,
Agro
business
6.
Dwelling
for
the
people engaged in the
farm (rural settlement)
7. Farm
houses
and
accessory buildings
8. Country Homes
9. Afforestation
1.
Houses incidental to
this use
2.
Wayside shops arid
restaurants
3. Cottage industries
4.
Hospital for infectious
and
contagious
diseases,
mental
hospital
after
clearance from the
Authority
5. Burial and
crematorium
grounds.
6.
Ice
factory,
cold
storage
7.
Service
industries
accessory
to
obnoxious
and
hazardous industry
8.
Godowns
and
warehouses
9.
Normal expansion of
land uses only in the
existing
homestead
land
10. Soil testing lab
11. Solid
waste
1.
Use/activity
not
compatible
to
the
land use
2.
Heavy,
extensive,
obnoxious,
noxious
and
hazardous
industries
3.
Any activity which is
creating nuisance and
is obnoxious in nature
4.
For
notified
forest
lands,
only
afforestation
is
permitted
15
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
management
sites,
sewage
disposal
works
12. Electric substation
13. Quarrying of gravel,
sand, clay or stone
14. Building construction
over plots covered
under town planning
scheme
and
conforming uses
15. Brick
kilns
and
extractive areas
16. Eco-tourism,
camping sites, eco-
parks, eco lodges,
Special
outdoor
recreations
(permissible by the
Competent Authority)
10.
Water Bodies
Use Zone
1. Rivers, canals
2. Streams, water spring
3.
Ponds,
lakes,
Reservoir
4. Wetland,
Waterlogged/marshy
area, aquaculture pond
1. Fisheries
2.
Boating,
water
theme parks, water
sports,
lagoons,
Public Projects
of
entertainment parks
as per approved plan
of Government
3.
Water based resort
with special by-laws
4.
Any
other
use/activity
incidental to Water
1.
Use/activity
not
compatible to the land
use
11.
Environment
ally sensitive
zone
1.
River side green areas,
River
front
developments
2.
Scenic
value
areas,
Theme
parks,
yoga
parks, sports centres
and
community
recreational areas,
3. sculpture complex,
4.
lagoons
and
lagoon
resort,
5. water sports,
6. Art academy,
7. Music pavilions
8. Media centres,
9. Food courts,
10. Parking areas,
11. visitor facilities
12. Existing
village
settlements,
Existing
residential
or
other
uses
13. Boating, Picnic huts,
1.
Hospitals and health
Institutions
2. Educational
technical,
research
institutes of higher
order
3.
Water
Treatment
Plant,
Sewage
Treatment
Plant,
Solid
waste
Treatment
Plant
solid waste dumping
ground
4.
Micro
Composting
Site
5.
Apartment buildings
having 100% stilt.
6.
Plotted development
Scheme
with
minimum 2Ha area
7.
Development
between
river,
stream, canal and
1.
Use/activity
not
compatible to the land
use
2. Plotted Housing
3.
Small industries or
small institutions
16
Sr.
No
Land Use
Zone (LUZ)
Uses/Activities
Permitted
Uses/Activities
Permissible on
recommendation of
DP&BP Committee
Uses/Activities
Prohibited
(a)
(b)
(c)
(d)
(e)
Camping sites Special
Training camps
14. Tourist
and
pilgrim
related
commercial
activities, hotels and
lodges
15. Non-polluting,
agro-
based and processing
industries, Storage or
Godowns
for
food
grains
the
embankment
with
clearance
of
Water
Resource
Department or any
other
competent
authority
8. International
convention centre
9. Kalyan Mandap
10. Resorts
CHAPTER
IV
GENERAL
9. Means of access
(1)
Every building or plot shall abut on a public or private means of access like streets, roads of duly formed
of width as specified in Part-3, clause 4 of the National Building Code of India, 2016.
(2)
In no case, development of plots shall be permitted unless it is accessible by a public or private street
of width not less than 4.50 meter;
In case of means of access is less than 4.50 meter, for residential development additional front setback
shall be left from the plots on both the sides equally so that the width of the means of access shall be
at least 4.50 meter. This is in addition to the mandatory front setback required as per the provisions of
these regulations.
(3)
In case of private access road of 5-10 ft resulted by sub-division (Ismail access), the following
regulations are applicable:
(i) Minimum width of access for plot development 1.5 m (5 ft). Such means of access shall be kept
free from any obstruction and shall be fully open to the sky;
(ii) Only residential development is permitted on such plots; maximum permissible FAR is 1.0;
(iii) No development permission shall be permitted for plots non- compliant to the above conditions.
(4)
In case of institutional, administrative, special buildings, assembly, industrial, educational & other non-
residential activities, the minimum road width shall be 9.00 meter; in case of commercial uses, the
minimum road width shall be 6.00 meter and in case of cinemas, game centers, multiplexes, convention
centers and shopping mall; the minimum road width shall be 12.00 meter;
Mixed-use buildings may be permitted on minimum of 7.5 m wide access for plot area up to 500 sq.m;
for plots above 500 sq.m up to 1000 sq.m, minimum access width required is 9.00 meters;
In case of special buildings, the DP&BP committee may relax the road width criteria and othe
requirements considering the site condition and requirement of such facility in the area.
(5)
In case of a private road, which gives access to one or more buildings, the owner of the said private
road shall develop the road and storm water drain as required by the Local Authority and transfer the
same by way of deed of gift to the Local Authority for maintenance.
17
(6)
In case of application for revalidation to the permission issued earlier, the provision of the width of the
means of access as prescribed under earlier Regulations shall be insisted upon.
10. Minimum area of plots
The minimum area of plots for different categories of buildings in Old Area is given in the Table 2 below:
Table 2 Category wise size of plots and minimum width of access
Category
Minimum Road width
(meter)
Minimum area of plot
(square meter)
Individual Residential use
4.50
30
Kalyan Mandaps
9.00
500
Cinema,
game
centers,
Multiplex,
convention centers
12.00
2000
Social clubs and amenities
9.00
1000
Multi-storied car parking
9.00
1000
Office buildings
9.00
300
Primary/Upper Primary school
9.00
2000
High School, Residential school
9.00
6000
+2 College / Junior college
9.00
4000
Degree College
9.00
6000
Technical educational institution
9.00
10000
Petrol pumps / Filling stations
9.00
500
Restaurant
9.00
200
LPG storages
9.00
500
Places of congregation
9.00
500
Public libraries
9.00
300
Conference hall
9.00
1000
Community hall
9.00
500
Nursing homes/polyclinics/ Hospital and
other clinical establishments
9.00
300
Hotels
9.00
1000
R & D Lab
9.00
1500
11. Minimum setbacks for non-high-rise buildings
(1) The minimum setbacks permissible in a given size of plot for residential and commercial building from
existing or proposed road shall be as per the Table 3 below.
(2) The setbacks are to be left after leaving the affected area of the plot/ site, if any, for road widening.
18
Table 3 Minimum setbacks for non-high-rise buildings in Old Area
Sr.
No.
Plot size
Min Front
setback
(meter)
Total cumulative
Front and Rear
Setback (meter)
Total cumulative
side Setbacks
(meter)
1
Up to 115 Sq.m (
Up to 1200 Sq.ft)
1.0
0.0
2
Above 115-170 Sq.m
(
1200-1800Sq.ft)
1.0
1.5
0.0
3
Above 170
225 Sq.m
(
1800-2400Sq.ft)
1.0
2.0
1.25
4
Above 225-300Sq.m
(
above 2400 Sq.ft and up to 3200 Sq.ft)
1.5
2.5
1.5
5
Above 300 sq.m and up to 500 Sq.m
(
above 5300 Sq. ft and up to 5300Sq.ft)
1.5
3.0
2.5
6
Above 500 sq.m-750 sq.m (
above 3200
Sq.ft and up to 8000 Sq.ft)
1.5
3.5
3.0
7
Above 750 sq.m.(
above 8000 Sq.ft)
2.0
3.5
4.0
12. Minimum setbacks for high rise buildings
(1) For non-high rise buildings, the open spaces around the building and ground coverage shall be as given
in Table 4 below.
(2) The setbacks are to be left after leaving the affected area of the plot/ site, if any, for road widening.
Table 4 Minimum setbacks and maximum ground coverage for high rise buildings
Sl. No
Height of the building
(in meter)
Minimum Setbacks on all
sides (In meter)
Maximum permissible Ground
Coverage (%of total plot area)
1.
15 and up to 18
4.50
50%
2.
More than 18 & up to 40
6.00
40%
3.
More than 40
9.00
40%
Note: In case of high-rise buildings the exterior open space around a building for a width of 7.5 meter shall
be kept unbuilt except where the open space requirement is less than 7.5 meter, the entire specified open
space shall be kept unbuilt. It shall be constructed of hard surface capable of taking load of fire engine
weighing up to 45 tons.
(3) For institutional buildings, the minimum setback around the building shall be 3.00 meter for non-high rise
building.
13. Floor Area Ratio
(1) The Floor Area Ratio (FAR) for all category of buildings shall be decided on the basis of the road width on
which the plot and site abuts as specified in Table 5 below:
19
Table 5 FAR for different access road widths
Sr. no
Road width (in meters)
Base FAR
Max permissible FAR
1.
4.50 or more & less than 6.00
1.50
1.50
2.
6.00 or more & less than 9.00
2.00
2.00
3.
9.00 or more & less than 12.00
2.00
2.50
4.
12.00 or more & less than 18.00
2.00
3.00
5.
18.00 or more
2.00
4.00
(2) For residential or commercial buildings on plot size of 170 Square meters (
1800 Sq.ft) or less and
building height of maximum 10 meters shall be permitted without any FAR limitation:
Provided that, if the building height on such plot exceeds 10 meters, then the provisions specified in Table
5 shall be applicable.
14. Development of access-restricted Plots
(1) In case of access-restricted plots more than 2000 sq.m, the minimum width of access to be provided by
the plot owner to avail development permission is 4.5 m.
Such access, in agreement with adjoining landowner may be availed through road of minimum 4.5 m width
with minimum clear height of 4.5 m. This is subject to mandated public safety and fire safety requirements,
and compliance to regulations and road geometrics as per standards.
The owner/s of the plot that have provided access shall be allotted development rights up to twice the base
FAR of land that has been surrendered to build such access. This FAR can be used in-situ as per Table
5 or in the form of TDR. CDA shall levy charges on the owner of the access restricted plot for providing
development rights over and above the base FAR on land surrendered for provision of this access. The
unit rate of such a charge would be determined as a percentage of the circle rate of such area as decided
by the authority.
FAR for the access-restricted plot shall be based on the nearest major public access road provided it
follows the conditions in Table 6:
Table 6 Permissible proportion of FAR for access restricted plot development
Length of access road
FAR permissible on plot as % of permissible FAR on fronting road
Up to 15 m
100%
30 m
85%
45
70%
60 m
55%
More than 60 m
50%
15. Off Street Parking Space
(1) In all buildings provision shall be made for parking spaces as per the requirements as given in the Table 7
below:
20
Table 7 Off Street Parking Space for Different Category of Occupancies
Sr.
No
Category of building/activity
Parking area to be provided
as percentage of total built up
area towards FAR.
1
Multiplexes, shopping malls, Cinema Halls, Auditorium, Stadium,
Sports complex, Gymnasium
50
2
Kalyan Mandaps, Banquet Halls, convention Halls & clubs,
Restaurants, local Retail shopping, Convenience Shopping , Banks,
Commercial and Corporate Office, Mercantile Buildings like shops/
stores/market display and sale of mercantile either wholesale or
retail stores, IT/ITES complexes, Hotels, Community Centers.
40
3
Residential Apartment buildings, Housing Project, Guest House,
Dharmashalas, Hostels, Work -cum-Residence lodging, Boarding,
Institutional, Industrial buildings
30
4
Storage godowns
20
(2) Total off-street parking space required as per the regulation can be provided by an individual or a group of
property owners at a place not more than 500 meters; such parking spaces may be construed to have met
the off-street parking requirement, subject to the approval of the Authority. The applicant/s must obtain a
plot via lease or purchase and such parking plot layout with ingress and egress must be submitted for
approval to the authority.
(3) Public parking (off street) may be provided with the following development incentives as listed below:
(i) Additional FAR equivalent to twice the base FAR of the plot will be provided in lieu of development of
such parking complex/ area of parking lot that can be used as TDR or bonus built up area which may
be consumed within the same land conforming to maximum FAR regulations
(ii) Relaxation of setbacks to 50% for building on plot where MLCP developed
(iii) Only parking for 2-wheelers may be permitted on roads below 4.5 m wide
16. General Building Requirements
The general building requirements of a building shall be as follows,
namely:
(i)
services can be permitted on roofs with adequate screening for the same;
(ii)
scissor staircase would be permitted provided all travel distance and fire norms are adhered to;
(iii)
stilts in high-rise buildings will not be restricted to height of 2.40 meters as long as it is used for parking;
(iv)
multilevel car parking with car lifts would be permitted with adequate fire safety;
(v)
buildings of height 200 meters and above, shall have provision for a Helipad.
(vi)
mezzanine floor may be permitted above any floor in all types of buildings up to an extent of one-third
of the actual covered area of that floor which shall have a minimum height of 2.20 meters and all
mezzanine floors shall be counted towards FAR calculation.
(vii)
The building components such as doorways, stairways, lifts, ramps, corridors and other parameters,
shall be as per the norms given in Annexure-IV.
Provided that, for buildings which require fire safety certificate under the provisions of Odisha Fire
Prevention and Fire Safety Regulations, 2017, as amended, from time to time, the building
components such as doorways, stairways, lifts, ramps, corridors and other such parameters shall be
21
as per norms given in Annexure
III.
CHAPTER
V
REQUIREMENT OF SPECIAL OCCUPANCY
17. Apartment
(1) In Apartment building with joint ownership of land, the owner or developer shall provide floor space for
minimum area shall not be less than 12 square meters.
(2) One staircase for every 6 dwelling units or fraction thereof in a floor shall be provided.
(3) The minimum width of approach road to the plot shall be at least 9.0 meters for Apartment buildings.
(4) Reservation of affordable housing i.e., EWS and LIG housing shall be done as per provisions of affordable
housing overlay.
CHAPTER
VI
DEVELOPMENT AND SUB-DIVISION OF LAND REGULATIONS
18. Size of the plot
No sub-divided plot shall be less than 30 square meters in area and the Authority shall have the right to relax
the same in special cases such as Affordable Housing Schemes.
19. Hierarchy and Width of Roads
(1) The hierarchy and width of roads in cases of sub-division layout shall be as per following extent,
namely:
(i) The site of sub-divisional layout shall have an access road from existing public or private pucca roads
as specified in Table 8 for layout with area up to 4 Ha:
Table 8: Minimum Road width (ROW) for Sub-division Layouts
Sr. No.
Area for Development (In Hectare)
Minimum Right of Way (meter)
1.
Up to 1.00
6.00
2.
1.0 to 4.00
9.00
Note: For EWS/LIG housing scheme, the minimum road width may be relaxed by the Authority.
For layouts above 4 Ha, ODA (P&BS) rules 2020 will be applicable
(ii) The width of the internal roads of a sub-division layout shall be as specified in Table 9 below:
Table 9 Minimum ROW of Internal Roads
Sl.No.
Length of Road(in Meters)
Minimum ROW (in Meters)
Residential
Non-residential and
Mixed Use
1.
Up to 250
6.00
9.00
22
2.
Above 250 and up to 500
9.00
12.00
3.
Above 500
12.00
15.00
Explanation:-The length of the road shall be distance from the middle point where the roads meets the
next higher roads.
(2) In case of layout for sub-division of plot in an existing built up old area surrounded by buildings, the
minimum width of access road can be relaxed by the DP&BP Committee and which can be done only in
such cases where there is no possibility of widening the access road to the proposed sub-division layout
to the standards as given in clause (i) of sub-rule (1) and this shall be subject to the condition that
maximum FAR on the individual plots in such a layout shall be proportionately reduced.
20. Reservation for Affordable Housing
(1)
Every plot with area more than 0.4 hectare shall have reservation of land for development of housing
units for EWS and LIG.
(2)
At least 10% (ten percent) of saleable residential land shall be earmarked for EWS and LIG category
or as per provisions of affordable housing overlay, whichever is higher.
CHAPTER
VII- COMPOUNDING
21. Restriction on compounding
(1) Any deviation pertaining to unauthorized development shall not be compounded in the following cases,
namely:
(i) where construction has been undertaken on Government land or land belonging to local body or land
not owned by the person undertaking such development;
(ii) where development has been undertaken unauthorizedly within the prohibited limits of any ancient
or archaeological monuments;
(iii) where such developments interfere with the natural drainage of the locality;
(iv) where such unauthorized development results in provisioning of parking below the prescribed norms;
and
(v) where road or drain whether public or private, whether constructed or natural, has been encroached.
(2) Subject to the provisions contained in sub-rule (1), the Authority shall have the power to determine other
such circumstances where compounding shall be prohibited.
(3) The Authority may, either before or after the institution of the proceedings under the provisions of the Act
compound any offence,
(i) where development has been undertaken without permission, but is within the framework of use
restrictions and provisions of these rules as applicable to the specific plot;
(ii) where deviations have been made up to 25% (twenty-five percent) beyond the permissible norms of
these rules in respect of front, rear and side setbacks within the permissible FAR limits on payment
of such compounding charges as may be prescribed in the regulations, from time to time.
(iii) where deviations have been made up to 10% (ten percent) in consumption of FAR beyond the
permissible limits on payment of such charges which are equivalent to charges notified for
23
Purchasable FAR.
22. Compounding Rates
Compounding Rates for various categories shall be as follows;
Table 10 Compounding Fees Categories
Sl.
No.
Situations
Compounding Fee of Sq.m. (in Rupees)
Individual
Residential
Buildings
State Govt./
Central Govt.
undertakings
Other class
of buildings
1.
Where development has been undertaken
without permission, but
within the
framework of use restrictions and the
provisions of the Regulations applicable to
concerned plot
250
25
400
2.
Where development has been undertaken
in deviation to the approved plan, but
within the framework of use, restrictions
and
the
provisions
of
norms
and
stipulations of these regulations.
100
10
250
3.
Constructions up to 10% beyond the
permissible norms of these Regulations
with respect to front, side and rear setback
and/or the deviation in FAR is within 5
percent of the permissible FAR.
1000
100
2000
4.
Constructions up to 25% beyond the
permissible norms of these Regulations
with respect to front, side and rear setback
and/or the deviation in FAR is more than 5
percent but within ten percent of the
permissible FAR.
2000
200
5000
5.
Where development has been undertaken
(other than residential/industrial) the deficit
parking up to 25% of the required parking.
-
-
12000
Note-
(1) In case of existing buildings with less than required off-street parking, the owner can obtain a plot via
lease or purchase for accommodating required parking within 500.00 m distance from such building. Such
parking plot layout with ingress and egress must be submitted for approval to the authority.
(2) In case of plots with Ismail access only 2-wheeler parking shall be permitted through a signed affidavit.
23. Power of the Govt. to Exempt
(1) Notwithstanding anything containing in these regulations, the Government may compound any deviations
in the construction undertaken prior to enforcement of this Regulation.
(2) For the purpose of compounding the deviation under clause (1) the Government may formulate a
regularization scheme either in respect of all types of construction or use specific construction specifying a
maximum time period of 6 months after publication of the same in Odisha gazette, local newspaper,
24
electronic media, website of the Government and Authority.
24. Removal of Unauthorized Construction
(3) The secretary of the Authority shall be competent to order for Removal of any construction which in his
opinion, is in violation of any of the provisions of the Act, Rules, or these Regulations, under the Act.
(4) The Secretary of the Authority may, if he is of such opinion, seek the advice of the Vice-Chairman regarding
implementation of any provision of these Regulations.
(5) The Vice-Chairman may call for any records, and in writing, give direction to the secretary for
implementation of any provision of these Regulations
CHAPTER
VII
MISCELLANEOUS
25. Extent & Applicability
These regulations are to be read in conjunction with ODA(P&BS) Rules- 2020, ODA (CAF) Rules- 2016
and where no express provision has been made in respect of any matter connected with these
regulations for old area the provision of ODA (P&BS) Rules 2020 shall be applied.
26. Applicability of National Building Code
Where no express provision has been made in respect of any matter connected with planning and building
standards in the Act or rules, Development Plan, Town Planning Schemes, or these Regulations or by any
resolution of the Authority; then in such cases provisions of the National Building Code of India shall apply,
mutatis mutandis, to such extent.
27. Applicability of provisions to committed project
Where any Department of the State Government or Local Body or Statutory Authority had given any
commitment for development of a project under PPP model prior to commencement of these regulations, then
the building plan of such a project shall be approved as per provisions of the regulations/rules then in force
under which such commitment was made, notwithstanding that these regulations has come into force.
28. Decision of the Government to be final
In case any doubt arises with respect to interpretation of these regulation or in case of any dispute in
interpretation of these regulations, the decision of the State Government shall be final.
29. Relaxation by the Government
The Authority may recommend to the State Government for relaxation or modification of any of the clauses
of these regulations in the general interest of the public pertaining to projects or schemes developed by the
State Government or any of its agency by itself or on PPP model or for any institutional building and the
decision of the State Government in this regard shall be final.
30. Precedent
The Authority may take into consideration, the information of an applicant for a building relating to cases of
relaxations granted by the Authority in the same area, zone or in similar cases while deciding the cases
under this Regulation to be decided by the DP&BP committee.
25
ANNEXURE I
Delineation of Old Area
Note: Planned Areas/Approved Layouts/Town Planning Schemes shall be excluded from the Old Area
Table 11: Delineation of Old Area
Sr.No
Ward
Sr.No
Ward
Sr.No
Ward
Sr.No
Ward
Sr.No
Ward
Sr.No
Ward
1
7
9
15
17
23
25
31
33
39
41
47
2
8
10
16
18
24
26
32
34
40
42
52
3
9
11
17
19
25
27
33
35
41
43
53
4
10
12
18
20
26
28
34
36
42
5
11
13
19
21
27
29
35
37
43
6
12
14
20
22
28
30
36
38
44
7
13
15
21
23
29
31
37
39
45
8
14
16
22
24
30
32
38
40
46
Table 12 Mouza Number of Plots included under the Old Area
Sr.No
Unit No & Mouza
1
UNIT NO-5 - DAKHINADEAULASAHI
26
2
UNIT NO-6 - UTARDEAULASAHI
3
UNIT NO-7 -UTAR TULASIPUR
4
UNIT NO-8 -DAKHINA TULASIPUR
5
UNIT NO-9 -BARABATI KILLA
6
UNIT NO-11 -ODIABAZAR
7
UNIT NO-12 -SUTAHAT
8
UNIT NO-13 -CHANDANI CHOWK
9
UNIT NO-14-NAYASADAK
10
UNIT NO-15 -CHAUDHURY BAZAR
11
UNIT NO-16 -KATHAGODASAHI
12
UNIT NO-10 -CANTONMENT
13
UNIT NO-17 -MACHUABAZAR
14
UNIT NO-18 -BUXIBAZAR
15
UNIT NO-20 -MANGLABAG
16
UNIT NO-21 -RANIHAT
17
UNIT NO-22- MIRKAMALPATNA
18
UNIT NO-23 -SAMANTASAHI
19
UNIT NO-24 -COLLEGE CHHAK
20
UNIT NO-25 -JOBRA
21
UNIT NO-26 -SIKHARPUR (P)
22
UNIT NO-27 -GANDARPUR
23
UNIT NO-28 -PAISA
24
UNIT NO-34 -DOLAMUNDAI
25
UNIT NO-36 -RAJABAGICHA
26
UNIT NO-29 -CHAULIAGANJ
27
UNIT NO-30 -ANDARPUR
28
UNIT NO-31 -GUNADALA
29
UNIT NO-32 -MADHUPATNA (P)
30
UNIT NO-33 -BISINABAR
31
UNIT NO-35 -JHANJRMANGLA
32
UNIT NO-37 -BADAMBADI
33
UNIT NO-38 -ARUNDAYANAGAR
34
UNIT NO-39 -SILPAPURI (P)
35
UNIT NO.55, NUAPADA (P)
27
ANNEXURE II
NBC 2016 References
Part 2 Administration: Clause 12.4.1 (Pg 14, NBC Part 1)
28
Part 2- Administration- Clause (Pg 13)
29
30
31
32
ANNEXURE III STANDARDS FOR FIRE PROTECTION AND FIRE SAFETY REQUIREMENTS
(Extract taken from National Building Code of India
For the complete provision, refer Part-IV of NBCI) (See
clause (v) of sub-regulation (3) of regulation 5, regulation 57 and clause (viii) of regulation 44)
(1)
Scope: The Part-4 of NBCI covers the requirements for fire prevention, life safety in relation to fire and fire
protection of buildings. This Part of NBCI specifies occupancy-wise classification, constructional aspects,
egress requirements and protection features that are necessary to minimize danger to life and property from
fire. Lifts escalators and revolving doors shall not be considered as exits.
(2) The provisions of this Part are applicable to the followings unless otherwise mentioned specifically in the
provisions:
(i) all high rise buildings; and
(ii) special buildings, those are,
(a)
hotel, educational, institutional, business, mercantile, industrial, storage, hazardous and mixed
occupancies, where any of these buildings have floor area more than 500 square meters on any
one or more floors;
(b)
educational buildings having height 9000 m. and above;
(c)
institutional buildings having height 9.00 m. and above;
(d)
all assembly buildings;
(e)
buildings, having area more than 300 square meters of incidental assembly occupancy on any
floor; and
(f)
buildings with two basements or more, or with one basement of area more than 500 square meter.
(3) The extract of the provisions related to life-safety of Part-IV of NBCI in relation to general exit requirements,
occupant load and egress components, are given in the subsequent part of this annexure:
33
34
35
36
37
38
39
40
41
42
43
44
ANNEXURE IV
GENERAL BUILDING
REQUIREMENTS
1. Doorways:
(i)
Every doorway shall open into an enclosed stairway, a horizontal exit, on a corridor or passageway
providing continuous and protected means of egress.
(ii)
No exit doorway shall be less than 1 meter in width. Doorways shall be not less than 2 meter in height.
Doorways for bathrooms, water closet and stores shall be not less than 0.75 meter wide.
(iii)
Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along
any exit. No door, when opened, shall reduce the require width of stairway or landing to less than 0.9
meter, overhead or sliding doors shall not be installed.
(iv)
Exit door shall not open immediately upon a flight or stairs, a landing equal to at least the width of the
door shall be provided in the stairway at each doorway, level of landing shall be the same as that of
the floor which it serves.
(v)
Exit doorways shall be openable from the side which they serve without the use of a key.
(vi)
Mirrors shall not be placed in exit ways or exit doors to avoid confusion regarding the direction of exit.
(vii)
Revolving doors shall not be provided as a means of fire exit
2. Stairways:
(i)
A staircase shall not be arranged round a lift shaft.
(ii)
The natural ventilation requirement of the staircase shall be, achieved through opening at each
landing, of an area 0.5 square meters in the external wall. A cross ventilated staircase shall have 2
(two) such openings in opposite/adjacent walls or the same shall be cross ventilated through the
corridor. The National Building Code of India, Chapter 4 Fire and Life Safety, Clause 4.4.2.5 Smoke
Control of exits shall be followed for requirement of Pressurized staircase in various building
components.
(iii)
The minimum width of staircase shall be as in Table-1 herein contained
Table 1: Type of Building and Staircase Width
Sl.No.
Type of Building
Width (m)
(a)
(b)
(c)
1
Residential buildings (dwellings)
1.00
2
Residential Hotel Buildings
1.50
3
Assembly buildings e.g., auditorium, theatres and cinemas
2.00
4
Educational buildings up to 30 meter in height
1.50
5
Institutional buildings like hospitals
2.00
6
All other buildings
1.50
(iv)
The minimum width of treads without nosing shall be 0.25 meter for staircase of residential buildings.
In the case of other buildings, the minimum tread shall be 0.30 meter. The treads shall be constructed
and maintained in a manner to prevent slipping. The maximum height of riser shall be 0.19 meter in
the case of residential buildings and 0.15 meter in the case of other buildings and the number of riser
45
shall be limited to 12 per flight.
(v)
Handrails shall be provided with a minimum height of 0.9 meter from the center of the tread.
(vi)
Handrail shall be provided on both sides of the staircase if the width of staircase is 1.50 meter or
more.
(vii)
The minimum headroom in a passage under the landing of a staircase and under the staircase shall
be 2.20 meter.
(viii)
Access to exit staircase shall be through a fire door of a minimum 120 minute fire resistance rating.
It shall be a swing type door opening in the direction of the escape.
(ix)
No living space, store or other fire risk shall open directly into staircases.
(x)
External exit door of staircase enclosure at ground level shall open directly to the open spaces or can
be reached without passing through any door other than a door provided to form a draught lobby.
(xi)
The exit sign with arrow indicating the way to the escape route shall be provided at a height of 0.5
meter from the floor level on the wall and shall be illuminated by electric light connected to corridor
circuits. All exit way marking signs shall be flushed with the wall and so designed that no mechanical
damage shall occur to them due to moving of furniture or other heavy equipment's. Further all landings
of floor shall have floor indication boards indicating the number of floor. The floor indication board
shall be placed on the wall immediately facing the flight of stairs and nearest to the landing. It shall
be of size not less than 0.50 meter × 0.50 meter and it shall be prominently on the wall facing the
staircase.
(xii)
In case of single staircase, it shall terminate at the ground floor level and the access to the basement
shall be by a separate staircase. The second staircase may lead to basement levels provided the
same is separated at ground level by either a ventilated lobby with discharge points at two different
ends or through enclosures with fire resistance rating door (Table-1, Part IV of the National Building
Code of India revised time to time) or through a fire protected corridor.
3. Lifts: General requirements of lifts shall be as follows:
(i)
All the floors shall be accessible for 24 hours by the lifts. The lifts provided in the buildings shall not
be considered as a means of escape in case of emergency. In a dual line arrangement (lifts opposite
to each other) the lobby may be between 1.5 times to 2.5 times the depth of one car. For in-line
(single line) arrangements the lobby may be typically half of the above recommendations.
(ii)
Grounding switch, at ground floor level, to enable the fire service to ground the lift shall also be
provided.
(iii)
The lift machine room shall be separate and no other machinery shall be installed there in.
(iv)
Walls of lift enclosures and lift lobby shall have fire rating of 2 hour; (National Building Code of India);
lifts shall have a vent at the top of area not less than 0.2 square meter.
(v)
Lift car door shall have a fire resistance rating of 1 hour.
(vi)
Lift lobby doors in lift enclosures shall have fire resistance as per relevant provision of the National
Building Code of India.
(vii)
Collapsible gates shall not be permitted for lifts and shall have solid doors with fire resistance of at
least 1 hour.
(viii)
Lifts if communicating with the basement, the lift lobby of the basements shall be pressurized as
suggested in Annexure-III (Fire Protection and Fire Safety Requirements) with self-closing door with
46
fire resistance rating. Telephone or other communication facilities shall be provided in lift cars and to
be connected to fire control room for the building.
(ix)
Suitable arrangements such as providing slope in the floor of lift lobby shall be made to prevent water
used during firefighting etc., at any landing from entering the lift shafts.
(x)
A sign shall be posted and maintained on every floor at or near the lift indicating that in case of fire,
occupants shall use the stairs unless instructed otherwise. The sign shall also contain a plan for each
floor showing the locations of the stairways. Alternate source of power supply shall be provided for
all the lifts through a manually operated changeover switch.
(xi)
The National Building Code of India, Chapter 4 Fire and Life Safety, Clause 4.4.2.5 Smoke Control
of exits may be followed for requirement of Pressurized lifts in various building components.
4. Ramps:
(i)
In the case of parking spaces provided in basement(s) and upper storey of parking floors, at least
two ramps of width and slope as per Table 2 shall be provided, located preferably at opposite ends.
Table 13 Requirements for ramp for vehicles
Sl
No.
Type of
Vehicle
One way ramp
width (in
meters)
Two way ramp
width (in
meters)
Maximum
continuous
ramp length
(in meters)
Minimum width
of ramp landing
(in meters)
Maximum
slope of ramp
(in meters)
(a)
(b)
(c)
(d)
(e)
(f)
(g)
1
LMV
3.00
6.00
40.00
6.00
1:80
2
LCV
4.50
9.00
3
HMV
6.00
12.00
4
fire tender
7.50
40.00
6.00
1:10
Note.
1. Such ramps may be permitted in the side and rear setbacks after leaving 6 meters space for
movement of fire-fighting vehicles;
2. The parking of vehicles at different level may also be mechanized.
3. In case of underground/multistoried parking, special measures with regard to fire safety shall be
taken in compliance to Part 4-Fire and Life Safety of NBCI.
(ii)
Ramp may also be provided in setback area which can be sloped considering unhindered movement
of fire Engine and in no case the gradient shall be less than 1:10.
(iii)
All structural design/safety aspects shall be complied per latest BIS Codes and National Building
Code of India along with consideration of weight of Fire Engine and its maneuverings.
(iv)
The minimum width of the ramps in hospitals shall be 2.40 meters for stretcher and not for vehicular
movement.
(v)
In this case Handrails shall be provided on both sides of the ramp.
(vi)
Ramps shall lead directly to outside open space at ground level or courtyards or safe place.
(vii)
Requirement of accessibility for elders and persons with disabilities shall be ensured in compliance
with the provisions of Annexure-VIII which may require providing ramps with specified gradient or
accessible lifts for access to different levels.
47
5. Corridors:
(i)
Exit corridors and passageways shall be of width not less than the aggregate required width of exit
doorways leading from them in the direction of travel to the exterior.
(ii)
The minimum width of a corridor in a residential building shall be 1.0 meter for single loaded and 1.80
meters for double loaded and in all other buildings shall be 1.50 meters.
(iii)
In Hospitals, the corridors through which patients are moved, shall have a minimum width of 2.40 m
throughout and corridors in other areas of hospital not intended for the housing, treatment, or use of
inpatients shall be not less than 1.50 m in width.
(iv)
Where stairways discharge through corridors and passageways, the height of corridors and
passageways shall be not less than 2.40 meters.
(v)
All means of exit including staircases lifts lobbies and corridors shall be ventilated.
6. Glass Facade/ Service Ducts/Shafts/ Refuge Area/ Vents
(i)
An Opening to the glass facade of min. width 1.5 meters and height 1.50 meters shall be provided at
every floor at a level of 1.20 meters from the flooring facing compulsory open space as well as on
road side. Construction that complies with the fire rating of the horizontal segregation and has any
gap packed with a non- combustible material to withstand thermal expansion and structural
movement of the walling without the loss of seal against fire and smoke.
(ii)
Mechanism of Opening: The openable glass panel shall be either left or right shall have manual
opening mechanism from inside as well as outside. Such openable panels shall be marked
conspicuously so as to easily identify the openable panel from outside.
(iii)
Fire seal to be provided at every floor level between the external glazing and building structure.
(iv)
The glazing used for the facade shall be of toughened (tempered) safety glass as per I.S. 2553.
(v)
To avoid fire propagation vertically from one floor to another floor, a continuous glass must be
separated internally by a smoke/ fire seal which is of non-combustible material having a fire resistance
rating of not less than 2 hours.
(vi)
Service ducts and shafts shall be enclosed by walls and doors with fire resistance rating. All such
ducts or shafts shall be properly sealed and stopped fire ingress at all floor levels.
(vii)
A vent opening at the top of the service shaft shall be provided having an area between one- fourth
and one-half of the area of the shaft.
(viii)
Glass quality and Practice of use of Glass in buildings shall have to be in conformity with the BIS
codes as given in Table 3 herein contained.
Table 3: Glass quality and Use of glass in buildings
Sl. No.
IS Code
Specifications
(a)
(b)
(c)
1
2553 (Part 1): 1990
Specification for safety glass: Part 1 General purpose (third revision)
2
2835:1987
Specification for flat transparent sheet glass (third revision)
3
438:1994
Specification for silvered glass mirrors for general purposes (second
revision)
4
5437:1994
Specification for figured rolled and wired glass (first revision).
48
Sl. No.
IS Code
Specifications
(a)
(b)
(c)
5
14900:2000
Specification for transparent float glass.
6
16231 Part 1
General methodology for selection
7
16231 Part 2
Energy and Light
8
16231 Part 3
Fire and Loading
9
16231 Part 4
Safety related to Human Impact
7. Building Services
(i)
Staircase and Corridor Lighting
(a) The staircase and corridor lighting shall be on separate service and shall be independently
connected so as it could be operated by one switch installation on the ground floor, easily
accessible to firefighting staff at any time irrespective of the position of the individuate control of
the light points, if any.
(b) Staircase and corridor lighting shall also be connected to alternate supply from parallel high-
tension supply or to the supply from the stand-by generator.
(c) Emergency lights shall be provided in staircase and corridor or passageway, horizontal exits,
refuge area; and all wires and other accessories used for emergency light shall have fire
retardant property.
(ii)
Electrical Services
(a) The electric distribution cables or wiring shall be laid in separate duct which shall be sealed at
every floor with non-combustible materials having the same fire resistance as that of the duct.
Low and medium voltage wiring running in shaft and in false ceiling shall run in separate
conduits.
(b) Water mains, telephone cables, intercom cables, gas pipes or any other service line shall not
be laid in the duct for electric cables. Use of bus ducts/solid rising mains instead of cables is
preferred.
(c) The provision of dedicated telecommunication ducts for all new building proposals is mandatory
for conveyance of telecommunication and other data cables.
(d) Separate circuits for water pumps lifts, staircases and corridor lighting and blowers for
pressurizing system shall be provided directly from the main switchgear panel.
(iii)
Alternate Source of Electric Supply: A stand-by electric generator shall be installed to supply power
to staircase and corridor lighting circuits, fire lifts, the stand-by fire pumps, pressurization fans and
blowers, smoke extraction and damper system in case of failure of normal electric supply. The
generator shall be capable of taking starting current of all the machines and circuits stated above
simultaneously. If the stand-by pump is driven by diesel engine, the generator supply need not be
connected to the stand-by pump.
(iv)
Air-conditioning: Air-conditioning shall conform to the following:
(a) Escape routes like staircases, common corridors, lift lobbies. shall not be used as return air
passage.
(b) The ducting shall be constructed of substantial gauge metal in accordance with good practice.
49
(c) Wherever the ducts pass through fire walls or floors, the opening around the ducts shall be
sealed with materials having fire resistance rating of the compartment.
(d) Where duct crosses a compartment which is fire rated, the ducts shall be fire rated for same fire
rating. Further depending on services passing around the duct work, which may get affected in
case of fire temperature rising, the ducts shall be insulated.
(e) Metallic ducts shall be used even for the return air instead of space above the false ceiling.
(f) Where plenum is used for return air passage, ceiling and its fixtures shall be of non-combustible
material.
(g) The materials used for insulating the duct system (inside or outside) shall be of non-combustible
material; glass wool shall not be wrapped or secured by any material of combustible nature.
(h) Air ducts serving main floor areas, corridors, shall not pass through the staircase enclosure.
(i) The air-handling units shall be separate for each floor and air ducts for every floor shall be
separated and in no way inter-connected with the ducting of any other floor.
(v)
If the air-handling unit serves more than one floor, the recommendations given in clause (iv) shall
be compiled with, in addition to the conditions given below:
(a) Proper arrangements by way of automatic fire dampers working on smoke detector / or fusible
link for isolating all ducting at every floor from the main riser shall be made.
(b) When the automatic fire alarm operates, the respective air-handling units of the air-conditioning
system shall automatically be switched off.
(c) The vertical shaft for treated fresh air shall be of masonry construction.
(d) The air filters of the air-handling units shall be of non-combustible materials or fire rated.
(e) The air-handling unit room shall not be used for storage of any combustible materials.
(f) Inspection panels shall be provided in the main trunking to facilitate the cleaning of ducts of
accumulated dust and to obtain access for maintenance of fire dampers.
(g) No combustible material shall be fixed nearer than 150 mm to any duct unless such duct is
properly enclosed and protected with non-combustible material (glass wool or spyglass with
neoprene facing enclosed and wrapped with aluminum sheeting) at least 3.2 mm thick and which
would not readily conduct heat.
(vi)
Transformers:
(a) When transformers are housed in the building below the ground level it shall be necessarily in
the first basement in separate fire resistance room of 4 hours rating. Transformer shall be dry
type and shall be kept in an enclosure with walls, doors and cut-outs having fire resistance rating
of 4 hour. The room shall necessarily be at the periphery of the basement having separate and
direct access from open area at ground floor through a fire escape staircase. The entrance to
the room shall be provided with a steel door of 2 hours fire rating. A curb of a suitable height
shall be provided at the entrance in order to prevent the flow of oil from ruptured, transformer
into other parts of the basement. The switchgears shall be housed in a separate room separated
from the transformer bays by a fire- resisting wall with fire resistance not less than 4 hours.
(b) The transformer shall be protected by an automatic foam sprinkler system. When housed at
ground floor level it/they shall be cut-off from the other portion of premises by Fire Resisting
Walls of 4 hours rating.
50
(c) A tank of RCC construction of adequate capacity shall be provided at lower basement level to
collect the oil from the catch pit in case of emergency. The pipe connecting the catch-pit to the
tank shall be of non- combustible construction and shall be provided with a flame-arrester.
(d) The electric sub-station shall be located in a separate building in accordance with sub-regulation
(1) of regulation 68 and clause (a) of sub-regulation (1) of regulation 64 of the Indian Electricity
Regulations, 1956.
(e) In case this is not practically possible due to site conditions, the sub- station shall be located on
the ground floor. As far as possible sub-station shall not be installed in a basement, for such
situations special provisions like mechanical ventilation, wherever required, cable ducting, cable
trays, top/bottom entry of HV/LV cable, hooks on Transformer(s) and HV panels, adequate fire
detection and fire-fighting arrangement, adequate drainage, effective measures to prevent
flooding shall be provided. Adequate precautions shall also be taken for water proofing to
prevent seepage of water. A ramp shall also be provided with a slope, not steeper than 1 in 7,
for easy movement of equipment to and from sub-station.
(vii)
Fire regulations
The installations shall be carried out in conformity with the local regulations and
regulations made thereunder wherever they are in force. At other places the National Building Code
of India shall be followed.
(viii)
Gas supply:
(a) Town Gas / L.P. Gas Supply Pipes - Where gas pipes are run in buildings, the same shall be
run in separate shafts exclusively for this purpose and these shall be on external walls away
from the staircases. There shall be no interconnection of this shaft with the rest of the floors.
(b) LPG distribution pipes shall always be below the false ceiling. The length of these pipes shall
be as short as possible. In the case of kitchen cooking range area, apart from providing hood,
covering the entire cooking range, the exhaust system shall have to be designed to take care of
30 cubic meter per minute per square meter of hood protected area. It must have grease filters
using metallic grill to trip oil vapours escaping into the fume hood.
(c) For large/commercial kitchens all wiring in fume hoods shall be of fiberglass insulation. Thermal
detectors shall be installed into fume hoods of large kitchens for hotels, hospitals and similar
areas located in high rise buildings. Arrangements shall be made for automatic tripping of the
exhaust fan in case of fire.
(d) When LPG is used, the same shall be shut off. The voltage shall be of 24 V or 100 V DC operated
with the external rectifier. The valve shall be of the hand re-set type and shall be located in an
area segregated from cooking ranges. Valves shall be easily accessible. The hood shall have
manual facility for steam or carbon dioxide gas injection, depending on duty condition; and Gas
meters shall be housed in a suitably constructed metal cupboard located in a well-ventilated
space, keeping in view the fact that LPG is heavier than air and town gas is lighter than air.
(ix)
Boiler Room: Further, the following additional aspects may be taken into account in the location of
Boiler/Boiler Room:
(a) The boiler shall not be allowed in sub-basement but be allowed in the first basements away from
the escape routes.
(b) The boilers shall be installed in a fire resisting room of 4 hours fire resistance rating, and this
room shall be situated on the periphery of the basement. Catch pit shall be provided at the low
level. Entry to this room may be provided with a composite door of two hour fire resistance.
(c) The boiler room shall be provided with fresh air inlets and smoke exhausts directly to the
atmosphere.
51
(d) Foam inlets shall be provided on the external walls of the building at the ground floor level to
enable the fire services to use foam in case of fire.
(e) The furnace oil tank for the boiler, if located in the adjoining room shall be separated by fire
resisting wall of 4 hour rating. Entry to this room shall be provided with a composite door of 2
hour fire resistance. A curb of suitable height shall be provided at the entrance in order to prevent
the flow of oil into the boiler room in case of tank rupture.
Printed and Published by the Director, Directorate of Printing, Stationery and Publication, Odisha, Cuttack-10
Ex. Gaz. 2470—173+1