Servants of Knowledge
Extraordinary Gazette of India · Government of India

Notification of Government of India, Ministry of Power No. S. O. 2390(E), dated 8th October, 2012 published in the Extraordinary, Part II, Section 3, Sub-section (ii), the scheme at Sl. No. 8 may be read as under

Published 08 January 2013

Ministry
Ministry of Power
Department
NOT available
Office
NOT available
Gazetteid
NOT available ( 36283 )
Identifier
in.gazette.central.e.2013-01-08.36283
Languages
English, Hindi
Published at
Original source ↗

रजिस्ट्रीसं० डी० एल०-33004/99

REGD . NO. D. L. -33004/99

सत्यमेव जयते भारत का राजपत्र The Gazette of India

असाधारण

EXTRAORDINARY

भाग II-खण्ड 3-उप-खण्ड (ii ) PART II Section 3-Sub- section ( ii)

प्राधिकार से प्रकाशित

PUBLISHED BY AUTHORITY

सं. 78]

नई दिल्ली, मंगलवार , जनवरी 8 , 2013/पौष 18, 1934

No. 78 ]

NEW DELHI , TUESDAY , JANUARY 8 , 2013/PAUSA 18, 1934

विद्युत मंत्रालय

शुद्धि-पत्र

नई दिल्ली, 4 जनवरी , 2013

का.आ. 82(अ).-भारत सरकार , विद्युत मंत्रालय की दिनांक 8 अक्तूबर , 2012 को असाधारण , भाग- II , खण्ड-3 उप- खण्ड ( ii ) में प्रकाशित अधिसूचना सं. का.आ. 2390 (ङ ) , में क्रम संख्या 8 की स्कीम को निम्नानुसार पढ़ा जाए : -

स्कीम का नामः " पूर्वी क्षेत्र प्रणाली सुदृढ़ीकरण स्कीम- VI "

कार्य-क्षेत्रः

(i) दरभंगा में भावी विस्तार स्थान (1 x 500 एमवीए) के साथ , 2 x 500 एमवीए, 400/220

केवी जीआईएस उप- केन्द्र की स्थापना

> 400 केवी लाइन बेज

> 400 केवी आईसीटी बेज

> 220 केवी लाइन बेज

> 220 केवी आईसीटी बेज

> भावी बेज के लिए स्थान

> 125 एमवीएआर बस रिएक्टर

> बस रिएक्टर बेज

* - दरभंगा उप-केन्द्र को दरभंगा शहर के समीप स्थापित किया जाना है

(ii) मोतीहारी में भावी में विस्तार स्थान ( 1 x 200 एमवीए) के साथ , 2 x 200 एमवीए,

400/132 केवी जीआईएस उप-केन्द्र की स्थापना

> 400 केवी लाइन बेज

> 400 केवी आईसीटी बेज

> 132 केवी लाइन बेज

> 132 केवी आईसीटी बेज

114 GI/2013

(1) 2

THE GAZETTE OF INDIA : EXTRAORDINARY

[PART II -SEC . 3 ( ii) ]

> भावी बेज के लिए स्थान

125 एमवीएआर बस रिएक्टर

बस रिएक्टर बेज

* - मोतीहारी उप- केन्द्र को मोतीहारी शहर के समीप स्थापित किया जाना है

(iii ) ट्रिपल स्नोबर्ड कंडक्टर वाली मुजफ्फरपुर (पीजी) दरभंगा 400 केवी डी/ सी लाईन

(iv) मोतीहारी , 400 केवी 2 x डी/ सी क्वाड में बाढ़- गोरखपुर 400 केवी डी/ सी लाइन का लीलो

(v) बाढ़- मोतीहारी खण्ड के लिए मोतीहारी छोर पर (600 ओम एनजीआर के साथ ) 2 x 80 एमवीएआर लाइन रिएक्टर्स (स्विचेबल)

(vi) मोतीहारी- गोरखपुर खण्ड के लिए मोतीहारी छोर पर (400 एनजीआर के साथ ) 2 x 50 एमवीएआर लाइन रिएक्टर्स (निर्धारित)

2. असाधारण- भाग।। खंड- 3- उपखंड( ii ) में प्रकाशित भारत सरकार, विद्युत मंत्रालय की अधिसूचना संख्या का. आ. 2391 (ङ) दिनांक 8.10.2012, का. आ. 1956 (ङ) दिनांक 24.8.2011 तथा का. आ. 2314(ङ) दिनांक 7.10.2011 में निम्नलिखित दो स्कीमों का संशोधित कार्य क्षेत्र निम्नानुसार है:

(i) स्कीम का मूल नामः

टोरंट पावर लि. , के डीजीईएन टीपीएस (1200 मेगावाट) तथा श्रीनगर( उत्तराखंड) और टेहरी के बीच इंटर- कनैक्शन से संबद्ध पारेषण प्रणाली "

स्कीम का संशोधित नाम ( दिनांक 8.10.2012 की राजपत्र अधिसूचना के अनुसार) :

" टोरंट पावर लिमिटेड के डीजीईएन टीपीएस ( 1200 मेगावाट) से संबद्ध पारेषण प्रणाली "

संशोधित कार्य क्षेत्रः

i) डीजीईएन टीपीएस बड़ोदरा 400 केवीडी/ सी (ट्विन मूज)

ii ) बड़ोदरा ( पीजी) एस/ एस पर दो 400 केवी लाइन बेज ( जीआईएस)

iii) नवसारी- भीस्टन 220 केवी डी/सी लाइन

iv) नवसारी ( पीजी) एस / एस पर दो 220 केवी लाइन बेज

v) भीस्टन (गेटको) एस/ एस पोपदा ( भीस्टन) पर नया एस/एस) पर दो 220 केवी लाइन बेज

(ii) स्कीम का मूल नामः

विजाग - वेमागिरी परियोजना- हिंदुजा (1040 मेगावाट) के लिए निकास प्रणाली '

स्कीम का संशोधित नाम (दिनांक 8.10.2012 की राजपत्र अधिसूचना के अनुसार) - * पूर्वी क्षेत्र से विद्युत के आयात के लिए दक्षिणी क्षेत्र में प्रणाली सुदृढीकरण "

संशोधित कार्य क्षेत्र

(i) श्रीकाकुलम पीपी- वेमागिरी- ।। पूलिंग स्टेशन 765 केवी डी/ सी लाइन

(ii ) खम्माम (नया) - नागार्जुन सागर 400 केवी डी/ सी लाइन

[फा. सं. 15/1/2011 - पारेषण ]

अरूण कुमार , निदेशक [ भाग II-खण्ड 3 (ii ) ]

भारत का राजपत्र असाधारण

3

MINISTRY OF POWER

CORRIGENDUM

New Delhi , the 4th January, 2013

S.O. 82(E). In the Notification of Government of India, Ministry of Power No. S. O. 2390(E) , dated 8th October, 2012 published in the Extraordinary, Part II , Section 3 , Sub- section ( ii ) , the scheme at Sl . No. 8 may be read as under :

Name of the scheme: " Eastern Region System Strengthening Scheme- VI "

Scope:

(i ) Creation of 2x500 MVA, 400/220 kV GIS Substation at Darbhanga with space for future extension (1x500 MVA)

→ 400 kV Line bays

→ 400 KV ICT bays

→ 220 kV Line bays

→ 220 kV ICT bays

→ Space for Future bays

→ 125 MVAR bus reactor

→ Bus reactor bays .

* - The Darbhanga S/S to be located near Darbhanga town

( ii ) Creation of 2x200 MVA, 400/132 kV GIS Substation at Mothihari with space for future extension ( 1x200 MVA)

→ 400 kV Line bays

→ 400 kV ICT bays

→ 132 kV Line bays

→ 132 KV ICT bays

→ Space for Future bays

→ 125 MVAR bus reactor

→ Bus reactor bays .

* - The Mothihari S/S to be located near Mothihari town

( iii ) Muzaffarpur ( PG ) - Darbhanga 400 kV D/ c line with triple snowbird conductor

( iv) LILO of Barh -Gorakhpur 400 kV D/c line at Mothihari , 400kV 2xD /C quad

(v) 2x80 MVAR Line reactors (Switchable) at Mothihari end ( with 600 ohm NGR) for Barh-Mothihari section

(vi ) 2x50 MVAR Line reactors ( fixed ) at Mothihari end (with 400 NGR) for Mothihari- Gorakhpur section 4

THE GAZETTE OF INDIA : EXTRAORDINARY

[PART II-SEC . 3 ( ii ) ]

2. Inthe Notification of Government of India , Ministry of Power No. S.O. 2391 ( E) dated 8.10.2012, S.O. 1956 ( E) dated 24.8.2011 and S.O. 2314 (E) dated 7.10.2011 published in the Extraordinary - PART II - Section -3 - Sub-section ( ii ) , the revised scope of the following two schemes are as follows:

(i) Original Name of the Scheme:

"Transmission system associated with DGEN TPS ( 1200 MW) of Torrent Power Ltd. AND Inter- connection between Srinagar ( Uttrakhand) and Tehri "

Revised Name of the Scheme ( as per Gazette Notification dated 8.10.2012) : "Transmission system associated with DGEN TPS ( 1200 MW) of Torrent Power Limited . "

Revised Scope :

i ) DGEN TPS - Vadodara 400 kV D /C ( twin Moose)

ii) Two no . 400 kV line bays ( GIS ) at Vododara ( PG ) S /S

iii) Navsari - Bheestan 220 kV D /C line

iv) Two no. 220 kV line bays at Navsari ( PG ) S/ S

v) Two no. 220 kV line bays at Bhestan ( GETCO ) S / S ( new S/S atPopda( Bhestan)

(ii) Original Name of the Scheme:

"Evacuation System for Vizag - Vemagiri Projects- Hinduja ( 1040 MW) "

Revised Name of the Scheme ( as per Gazette Notification dated 8.10.2012 ) : " System Strengthening in Southern Region for import of power from Eastern Region "

Revised Scope :

( i ) Srikakulam PP - Vemagiri - II Pooling Station 765kV D/C line

(ii ) Khammam ( new) - Nagarjun Sagar 400 kV D /C line

[ F. No. 15/ 1 /2011 -Trans ]

ARUN KUMAR, Director

Printed by the Manager , Government of India Press , Ring Road , Mayapuri , New Delhi - 110064 and Published by the Controller of Publications , Delhi - 110054.

Cite this issue. Extraordinary Gazette of India, Government of India, 08 January 2013. Indian Gazettes, https://egazette.servantsofknowledge.in/details/in.gazette.central.e.2013-01-08.36283/. Archive identifier in.gazette.central.e.2013-01-08.36283.